Skip to main content
  • Research article
  • Open access
  • Published:

Detrimental Effects of Filling Laryngotracheal Airways To Excessive Pressure (DEFLATE-P): a quality improvement initiative

Abstract

Background

This quality improvement (QI) project was performed at a single center to determine the incidence of postoperative complications associated with use of cuffed airway devices. An educational program was then completed that involved training our anesthesia providers about complications related to excessive cuff pressure and how to utilize a quantitative cuff pressure measurement device (manometer). The impact of this educational initiative was assessed by comparing the incidence of postoperative complications associated with the use of airway devices before and after the training period.

Methods

After approval by our institution’s Institutional Review Board, a pre-intervention (baseline) survey was obtained from 259 adult patients after having undergone surgery with general anesthesia with the use of an endotracheal tube (ETT) or laryngeal mask airway (LMA). Survey responses were used to determine the baseline incidence of sore throat, hoarseness, and dysphagia. Once these results were obtained, education was provided to the anesthesia department members addressing the complications associated with excessive cuff pressures, appropriate cuff pressures based on manufacturer recommendations, and instructions on the use of a quantitative monitor to determine cuff pressure (manometry). Clinical care was then changed by requiring intraoperative cuff pressure monitoring throughout our institution for all surgical patients. After this educational period, 299 patients completed the same survey describing postoperative airway complications.

Results

The use of manometry reduced the incidence of moderate-to-severe postoperative sore throat in the pre- vs. post-intervention groups (35 patients vs 31 patients, p = 0.045), moderate to severe hoarseness (30 patients vs 13, patients p = 0.0001), and moderate-to-severe dysphagia (13 patients vs 5 patients, p = 0.03).

Conclusion

Caring for patients in the perioperative setting frequently entails placement of an airway device. This procedure is associated with several potential complications, including sore throat, coughing, and vocal cord damage. Our quality improvement initiative has shown that intraoperative management of intra-cuff pressure based on manometry is feasible to implement in clinical practice and can reduce postoperative airway complications.

Peer Review reports

Background

Sore throat, dysphagia, and hoarseness are multifactorial postoperative complications after general anesthesia in which manipulation of the airway is required. The incidence of post-operative sore throat (POST) has been reported to occur in 17.5–26% of postoperative patients [1, 2] but some studies have reported incidences as high as 50% [3, 4]. The pathologic process has been suggested to involve direct mucosal injury and inflammation related to airway instrumentation and presence of foreign airway objects [5]. Excessive cuff pressures of airway devices have been implicated as a cause of POST [6, 7].

There are reports of mixed efficacy in prevention of POST by pharmacologic modalities, such as topical anesthetics [8]. Moreover, non-pharmacologic modalities, including preoperative licorice water gargling, [9] have also been reviewed, ultimately showing limited impact on complications [5, 7, 9]. Alternatively, Farhang et al. showed that preoperative zinc lozenges were able to reduce the incidence of POST by 24% (p < .05) within the first 2 post-operative hours [10].

Chang et al. demonstrated that tapered ETT cuffs, as compared to cylindrical ones, reduce post-operative sore throat by as much as 22% (p = .003) [11]. Interestingly, two studies comparing open abdominal surgery to laparoscopic techniques revealed that manometry-measured endotracheal tube (ETT) cuff pressures significantly increased after abdominal insufflation or Trendelenburg positioning, and subsequently resulted in more frequent POST events [12, 13]. Koyama et al. demonstrated that the application of lubricant to the cuff can prevent such increases in pressure via a reduction of gas diffusion into the cuff [14]. Another study compared a novel laryngeal mask airway (LMA) with intra-cuff pressure measurement versus a traditional LMA, finding a significant reduction in postoperative pharyngolaryngeal complications [15]. Interestingly, Corda et al. found that utilizing syringe rebound pressure alone (as a surrogate for measurement of intra-cuff pressure with manometry) was enough to reduce the incidence of POST [16]. In lieu of manometry, it is worthwhile to note two double-blind, randomized controlled trials that have reported success in reducing postoperative respiratory complications by titration of ETT cuff pressure based on the anesthesia machine volume-time curve and minimizing or eliminating the difference between the inspiratory and expiratory volume [17, 18]. None of these interventions, however, completely eliminated POST.

Most clinicians employ subjective measures to mitigate the burden of POST, such as manually palpating the pilot balloon to assess intra-cuff pressure. However, objective measurements of ETT cuff pressures to obtain and maintain recommended ranges provide a more significant reduction in these postoperative complications [6]. A review of several studies has recently introduced the idea of physical tissue damage as a precursor to postoperative airway complications [5], consistent with other recent studies regarding manometry [6, 7, 13, 19,20,21]. Minimizing airway cuff pressures may be the key to reducing POST. Although the use of manometry is not commonplace, the availability of new, compact and portable devices allows easy integration into everyday practice and may help reduce the incidence of postoperative complications [8, 19, 20]. We therefore initiated this quality improvement project to determine whether monitoring of cuff pressures (and presumably, preventing intraoperative cuff over inflation) would translate into improved patient care and a lower incidence of complications. We deliberately used a novel, easy to use, and inexpensive manometer (the AG CUFFILL) to facilitate provider acceptance and use. Other pressure monitors (for instance, Cufflator manometer, manufactured by Posey, Sulz, Germany) are much larger and more expensive, and need to be cleaned to prevent vertical bacterial transmission.

One of the most important etiologies of POST is tissue ischemia secondary to cuff over-distension. In our study, we sought to eliminate overinflated cuffs by measuring and ensuring appropriate intraoperative intra-cuff pressure. Our project aimed to determine the incidence of postoperative airway complications at our institution, and inform our anesthesia providers of these patient care concerns. We also sought to educate our department about airway complications that might be due to excessive airway device cuff pressures. Finally, we adjusted clinical practice to incorporate routine measurement of cuff pressures after airway manipulation and then investigated whether this practice change had an impact on the incidence and severity of POST.

Methods

After receiving Institutional Review Board (IRB) approval, a pre-intervention baseline assessment of POST complications was conducted through an originally developed questionnaire (Additional File 1) that documented the airway device utilized, dexamethasone administration, and contained questions delineating the severity of sore throat, hoarseness, coughing, and dysphagia in the postoperative period (Supplemental Material). The symptoms were rated on a 4-point subjective, verbal scale ranging from “none” to “severe.” A questionnaire was administered to adult patients (> 18 years old) who had undergone outpatient or inpatient surgery under general anesthesia with ETT or LMA. The questionnaires were completed prior to discharge from Phase 2 recovery. The discharge criteria are based on Aldrete’s Modified Phase I Post-anesthesia Recovery Score, as depicted in Table 1 [22]. No patients were excluded from participation in this post-operative assessment after the practice change was implemented, and pre-intervention questionnaires were collected over several months at random intervals. A power analysis was performed using the lowest reported incidence of POST (14.4%), considering a 50% reduction in the incidence as significant at p < 0.05. To reach statistical significance, a total of 200 patients (n = 200) were considered for inclusion. Of note, during the pre-intervention time period, physicians and nurse anesthetists were blinded to the project intent.

Table 1 Aldrete’s Modified Phase I Post Anesthesia Recovery Score

An educational module was created and distributed electronically to our anesthesia providers. The module contained pre-test questions and evaluated knowledge of the incidence of POST as well as the recommended ETT and LMA cuff pressures. Information on the reported incidence of POST and recommended cuff pressures was provided, as well as step-by-step text instructions for measurement of cuff pressure with an electronic manometry device (AG CUFFILL™), (Hospitech Respiration, Ltd., Mercury Medical, Clearwater, FL) (Fig. 1). This in-service was followed by a brief instructional video and a link to the manufacturer’s instructional video. Changes were made to the electronic medical record (EMR) prompting provider input of ETT and LMA cuff pressures before and after intervention. This built-in visual reminder assisted the transition of objective manometry assessment into everyday practice.

Fig. 1
figure 1

AG Cuffiill™ Manometry Device. The manometry device (cmH2O) provided for cuff pressure measurement during the post-interventiom phase

The post-intervention questionnaire was collected over 10 months, and contained questions identical to the pre-intervention questionnaire with additional fields for initial and adjusted cuff pressures, where applicable. Data analysis was performed using a two-tailed Fisher’s exact test to determine the impact our educational intervention on initial cuff pressures, adjusted cuff pressures, as well as the frequency of POST, hoarseness, and dysphagia.

Results

A total of 259 pre-intervention and 350 post-intervention questionnaires were collected over 23 months, including 362 ETTs and 152 LMAs (Fig. 2). Subsequently, 95 patients were excluded secondary to undergoing general anesthesia with a natural airway or monitored anesthesia care (MAC). The use of manometry reduced the incidence of moderate-severe postoperative sore throat in the pre- and post-intervention groups (35 patients vs 31 patients, p = 0.045, respectively). Moderate to severe hoarseness was also reduced with the application of manometry when comparing pre-intervention (initial pressure) and post-intervention (adjusted pressure) groups (30 patients vs 13 patients, p = 0.0001), respectively. Finally, moderate to severe dysphagia was also reduced with the use of manometry when comparing pre- and post- intervention groups (13 patients vs 5 patients, p = 0.03, respectively), as identified in Table 2. The use of manometry demonstrated that initial cuff pressures in both airway devices were consistently above recommended values. On average, the initial ETT cuff pressure was 38 ± 18 cm H2O. Average adjusted pressure for ETTs was 27 ± 4 cm H2O. Mean initial pressure for LMAs was 66 ± 18 cm H2O. Mean adjusted pressure for LMAs was 55 ± 8.4 cm H2O (Table 3).

Fig. 2
figure 2

Project inclusion criteria Flowchart. Pre and post intervention patients surveyed, included, and excluded from quality improvement project

Table 2 Reduction in Postoperative Airway Complications
Table 3 Post-intervention initial and adjusted cuff pressures (cm H2O)

Discussion

This QI project demonstrated that the utilization of a quantitative device that objectively determines the pressures of ETT and LMA cuffs can reduce the incidence of postoperative airway complications. Specifically, this action led to a significant reduction in the incidence of sore throat (p = 0.045), hoarseness (p = < 0.001), and dysphagia (p = 0.03) (Table 2).

Our findings were in congruence with previous studies. Liu et al. evaluated 509 patients undergoing elective surgery with general anesthesia and endotracheal intubation. These investigators determined that patients who had their cuff pressures adjusted had a lower incidence of post-operative sore throat (p = < 0.001) as well as decreased injury to tracheal mucosa as indicated by blood streaked expectoration (p = 0.089) [6]. A similar study conducted by Li et al. evaluated the incidence of post-operative respiratory complications in patients who underwent general anesthesia with LMAs and demonstrated lower LMA cuff pressures decreased incidence of sore throat (p = 0.022), and dysphagia (p = 0.007) [23].

While it is difficult to quantify the total cost of postoperative airway complications, the cost of the intervention is minimal. For instance, the AG CUFFILL device can be reused up to 100 times, since measurement of cuff pressures needs not be performed in a sterile fashion. The AG CUFFILL syringe, for instance, has a local cost of $20.00 per unit, resulting in a “cost per use” of only $0.20. The cost of reusable manometers such as the Cufflator™ (VBM Cuff Pressure Gauge, VBM Medizintechnik GmbH, Sulz, Germany) and the Portex Cuff Inflator Pressure Gauge (Smith Medical ASD Inc., Dublin, OH, USA) require a more substantial initial investment of $309.00 and $84.95, respectively. These devices are also larger than the AG CUFFILL syringe, making their use and storage in the limited OR setting much more problematic. These devices also need to be calibrated regularly and require routine maintenance, increasing their cost of use. In comparison, the AG CUFFILL device does not require routine calibration. While it is difficult to quantify the financial burden of postoperative airway complications, patient safety and satisfaction are universally paramount. Future endeavors describing the effects of confounders may help develop more appropriate and simpler methods to alleviate and prevent postoperative airway complications.

There are several limitations to our project. Manometry represents one objective measure to reduce postoperative respiratory complications; however this is a dilemma with a multitude of variables. Other factors not evaluated in our project that can contribute to POST include preoperative sore throat, trauma during instrumentation of a difficult airway, size of the airway device, the use of neuromuscular blocking agents, presence/absence of cuff lubrication, and length of surgery. Our project may have also been influenced by the Hawthorne Effect as providers knew that cuff pressures were going to be checked after our educational intervention.

As with any new endeavor, there will be challenges to implementation and resistance to alteration of current practice. Our initiative provides insight into such a process, with emphasis on brief, straight-forward education. With the marked reduction in unadjusted and adjusted cuff pressures during the post-intervention phase, our results reinforce how common overinflated cuff pressures are and establishes that utilizing a quantitative device to guide cuff pressure is feasible. In addition, the EMR (electronic medical record) can provide visual cues and reminders to the provider requiring the clinician to measure, adjust, and document the ETT and LMA cuff pressures. The online module, instructional videos, hands-on tutorial, as well as EMR reinforcement solidified the behavioral modification for cuff pressure monitoring. Future investigations are warranted to confirm such findings.

Conclusions

Caring for patients in the perioperative setting often entails placement of an airway device with potential adverse effects and complications that warrant further investigation. Our quality initiative has shown it is feasible to implement manometry into everyday practice, which resulted in a marked reduction in postoperative airway complications. As technology continues to advance, it is imperative for us to utilize the tools provided to our advantage, for the benefit of our patients, and the establishment of a refined standard of care.

Availability of data and materials

All original datasets used and analyzed during the current quality improvement project are available from the corresponding author on reasonable request.

Abbreviations

EMR:

Electronic Medical Record

ETT:

Endotracheal Tube

IRB:

Institutional Review Board

LMA:

Laryngeal Mask Airway

MAC:

Monitored Anesthesia Care

OP:

Over Pressure

POST:

Post-Operative Sore Throat

QI:

Quality Improvement

SD:

Standard Deviation

References

  1. Higgins PP, Chung F, Mezei G. Postoperative sore throat after ambulatory surgery. Br J Anaesth. 2002;88:582–4.

    Article  CAS  Google Scholar 

  2. Grady DM, McHardy F, Wong J, Jin F, Tong D, Chung F. Pharyngolaryngeal morbidity with the laryngeal mask airway in spontaneously breathing patients: does size matter? Anesthesiology. 2001;94:760–6.

    Article  CAS  Google Scholar 

  3. Christensen AM, Willemoes-Larsen H, Lundby L, Jakobsen KB. Postoperative throat complaints after tracheal intubation. Br J Anaesth. 1994;73:786–7.

    Article  CAS  Google Scholar 

  4. McHardy FE, Chung F. Postoperative sore throat: cause, prevention and treatment. Anaesthesia. 1999;54:444–53.

    Article  CAS  Google Scholar 

  5. Scuderi PE. Postoperative sore throat: more answers than questions. Anesth Analg. 2010;111:831–2. https://doi.org/10.1213/ANE.0b013e3181ee85c7.

    Article  PubMed  Google Scholar 

  6. Liu J, Zhang X, Gong W, et al. Correlations between controlled endotracheal tube cuff pressure and postprocedural complications: a multicenter study. Anesth Analg. 2010;111:1133–7. https://doi.org/10.1213/ANE.0b013e3181f2ecc7.

    Article  PubMed  Google Scholar 

  7. Tanaka Y, Nakayama T, Nishimori M, Tsujimura Y, Kawaguchi M, Sato Y. Lidocaine for preventing postoperative sore throat. Cochrane Database Syst Rev. 2015;(7):CD004081. https://doi.org/10.1002/14651858.CD004081.pub3.

  8. Arts MP, Rettig TC, de Vries J, Wolfs JF, In't Veld BA. Maintaining endotracheal tube cuff pressure at 20 mm Hg to prevent dysphagia after anterior cervical spine surgery; protocol of a double-blind randomised controlled trial. BMC Musculoskelet Disord. 2013;14:280. https://doi.org/10.1186/1471-2474-14-280.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Ruetzler K, Fleck M, Nabecker S, et al. A randomized, double-blind comparison of licorice versus sugar-water gargle for prevention of postoperative sore throat and postextubation coughing. Anesth Analg. 2013;117:614–21. https://doi.org/10.1213/ANE.0b013e318299a650.

    Article  CAS  PubMed  Google Scholar 

  10. Farhang B, Grondin L. The effect of zinc lozenge on postoperative sore throat: a prospective randomized, double-blinded, placebo-controlled study. Anesth Analg. 2018;126:78–83. https://doi.org/10.1213/ANE.0000000000002494.

    Article  CAS  PubMed  Google Scholar 

  11. Chang JE, Kim H, Han SH, Lee JM, Ji S, Hwang JY. Effect of endotracheal tube cuff shape on postoperative sore throat after endotracheal intubation. Anesth Analg. 2017;125:1240–5. https://doi.org/10.1213/ANE.0000000000001933.

    Article  PubMed  Google Scholar 

  12. Yildirim ZB, Uzunkoy A, Cigdem A, Ganidagli S, Ozgonul A. Changes in cuff pressure of endotracheal tube during laparoscopic and open abdominal surgery. Surg Endosc. 2012;26:398–401. https://doi.org/10.1007/s00464-011-1886-8.

    Article  PubMed  Google Scholar 

  13. Geng G, Hu J, Huang S. The effect of endotracheal tube cuff pressure change during gynecological laparoscopic surgery on postoperative sore throat: a control study. J Clin Monit Comput. 2015;29:141–4. https://doi.org/10.1007/s10877-014-9578-2.

    Article  PubMed  Google Scholar 

  14. Koyama Y, Oshika H, Nishioka H, et al. K-Y jelly inhibits increase in endotracheal tube cuff pressure during nitrous oxide exposure in vitro. BMC Anesthesiol. 2018;18:99. https://doi.org/10.1186/s12871-018-0566-9.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  15. Wong DT, Tam AD, Mehta V, Raveendran R, Riad W, Chung FF. New supraglottic airway with built-in pressure indicator decreases postoperative pharyngolaryngeal symptoms: a randomized controlled trial. Can J Anaesth. 2013;60:1197–203. https://doi.org/10.1007/s12630-013-0044-2.

    Article  PubMed  Google Scholar 

  16. Corda DM, Robards CB, Rice MJ, et al. Clinical application of limiting laryngeal mask airway cuff pressures utilizing inflating syringe intrinsic recoil. Rom J Anaesth Intensive Care. 2018;25:11–8. https://doi.org/10.21454/rjaic.7518.251.cuf.

    Article  PubMed  PubMed Central  Google Scholar 

  17. Bolzan DW, Gomes WJ, Faresin SM, de Camargo Carvalho AC, De Paola AA, Guizilini S. Volume-time curve: an alternative for endotracheal tube cuff management. Respir Care. 2012;57:2039–44. https://doi.org/10.4187/respcare.01812.

    Article  PubMed  Google Scholar 

  18. Bolzan DW, Gomes WJ, Peixoto TC, et al. Clinical use of the volume-time curve for endotracheal tube cuff management. Respir Care. 2014;59:1628–35. https://doi.org/10.4187/respcare.02683.

    Article  PubMed  Google Scholar 

  19. Seet E, Yousaf F, Gupta S, Subramanyam R, Wong DT, Chung F. Use of manometry for laryngeal mask airway reduces postoperative pharyngolaryngeal adverse events: a prospective, randomized trial. Anesthesiology. 2010;112:652–7. https://doi.org/10.1097/ALN.0b013e3181cf4346.

    Article  PubMed  Google Scholar 

  20. Ryu JH, Han SS, Do SH, Lee JM, Lee SC, Choi ES. Effect of adjusted cuff pressure of endotracheal tube during thyroidectomy on postoperative airway complications: prospective, randomized, and controlled trial. World J Surg. 2013;37:786–91. https://doi.org/10.1007/s00268-013-1908-x.

    Article  PubMed  Google Scholar 

  21. Chantzara G, Stroumpoulis K, Alexandrou N, Kokkinos L, Iacovidou N, Xanthos T. Influence of LMA cuff pressure on the incidence of pharyngolaryngeal adverse effects and evaluation of the use of manometry during different ventilation modes: a randomized clinical trial. Minerva Anestesiol. 2014;80(5):547–55.

    CAS  PubMed  Google Scholar 

  22. White PF, Song D. New criteria for fast-tracking after outpatient anesthesia: a comparison with the modified Aldrete's scoring system. Anesth Analg. 1999;88:1069–72.

    Article  CAS  Google Scholar 

  23. Li BB, Yan J, Zhou HG, Hao J, Liu AJ, Ma ZL. Application of minimum effective cuff inflating volume for laryngeal mask airway and its impact on postoperative pharyngeal complications. Chin Med J. 2015;128:2570–6. https://doi.org/10.4103/0366-6999.166034.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

We would like to extend our gratitude to all of the Mayo Clinic Florida post-anesthesia care unit staff, especially our nursing team leaders, for their assistance with the questionnaire.

Declarations

1. This paper has not been published or submitted for publication elsewhere.

2. The paper has been read by all co-authors.

3. The paper is being submitted under the category of original research

Funding

Not applicable

Author information

Authors and Affiliations

Authors

Contributions

AVF and MAV collected and analyzed patient data, AVF, MAV, and GJM contributed to manuscript preparation, SJB and JRR designed the project and edited the manuscript, All authors approved the final manuscript.

Corresponding author

Correspondence to Ashley V. Fritz.

Ethics declarations

Ethics approval and consent to participate

Mayo Clinic Institutional Review Board Waiver #14–007053 obtained for quality improvement project.

Written informed consent not required per IRB; all participants provided verbal consent to participate in the survey.

Consent for publication

Not applicable.

Competing interests

Not applicable, the authors declare they have no competing interests. SJB has intellectual property assigned to Mayo Clinic (Rochester, MN); has received research funding from Merck & Co., Inc. (funds to Mayo Clinic) and is a consultant for Merck & Co., Inc. (Kenilworth, NJ); is a principal and shareholder in Senzime AB (publ) (Uppsala, Sweden); and a member of the Scientific Advisory Boards for ClearLine MD (Woburn, MA), The Doctors Company (Napa, CA), and NMD Pharma (Aarhus, Denmark).

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary information

Additional file 1.

Postoperative Pharyngeal Assessment Questionnaire This is an internally developed questionnaire by our institution to assess the severity of sore throat, dysphagia, coughing and hoarseness of postoperative patients.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Fritz, A.V., Mickus, G.J., Vega, M.A. et al. Detrimental Effects of Filling Laryngotracheal Airways To Excessive Pressure (DEFLATE-P): a quality improvement initiative. BMC Anesthesiol 20, 46 (2020). https://doi.org/10.1186/s12871-020-00963-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12871-020-00963-6

Keywords