Effect of individualized PEEP titration guided by intratidal compliance profile analysis on regional ventilation assessed by electrical impedance tomography – a randomized controlled trial

Abstract

Background

The application of positive end-expiratory pressure (PEEP) may reduce dynamic strain during mechanical ventilation. Although numerous approaches for PEEP titration have been proposed, there is no accepted strategy for titrating optimal PEEP. By analyzing intratidal compliance profiles, PEEP may be individually titrated for patients.

Methods

After obtaining informed consent, 60 consecutive patients undergoing general anesthesia were randomly allocated to mechanical ventilation with PEEP 5 cmH2O (control group) or PEEP individually titrated, guided by an analysis of the intratidal compliance profile (intervention group). The primary endpoint was the frequency of each nonlinear intratidal compliance (CRS) profile of the respiratory system (horizontal, increasing, decreasing, and mixed). The secondary endpoints measured were respiratory mechanics, hemodynamic variables, and regional ventilation, which was assessed via electrical impedance tomography.

Results

The frequencies of the CRS profiles were comparable between the groups. Besides PEEP [control: 5.0 (0.0), intervention: 5.8 (1.1) cmH2O, p < 0.001], the respiratory and hemodynamic variables were comparable between the two groups. The compliance profile analysis showed no significant differences between the two groups. The loss of ventral and dorsal regional ventilation was higher in the control [ventral: 41.0 (16.3)%; dorsal: 25.9 (13.8)%] than in the intervention group [ventral: 29.3 (17.6)%; dorsal: 16.4 (12.7)%; p (ventral) = 0.039, p (dorsal) = 0.028].

Conclusions

Unfavorable compliance profiles indicating tidal derecruitment were found less often than in earlier studies. Individualized PEEP titration resulted in slightly higher PEEP. A slight global increase in aeration associated with this was indicated by regional gain and loss analysis. Differences in dorsal to ventral ventilation distribution were not found.

Trial registration

This clinical trial was registered at the German Register for Clinical Trials (DRKS00008924) on August 10, 2015.

Peer Review reports

Background

During mechanical ventilation, it is widely accepted that the application of low tidal volume and low driving pressure, i.e., the difference between plateau pressure (PPlat) and (positive) end-expiratory pressure (PEEP), protects the lung from the destructive effects of alveolar overdistension [1,2,3,4].

With regard to the conflicting clinical data regarding the setting of adequate PEEP during general anesthesia, many techniques have been developed to determine adequate PEEP [5,6,7,8]. One technique, first described in 1979 for patients with severe lung injury [9], is based on setting the PEEP slightly above the lower inflection point of the inspiratory limb of the static pressure-volume curve [5, 10, 11]. Other techniques focus on the respiratory system compliance (CRS). For example, PEEP can be titrated to reach the maximum quasi-static compliance, calculated by dividing tidal volume (VT) by the driving pressure [8, 12, 13]. However, a single compliance value cannot reflect the non-linearity of intratidal respiratory system mechanics during the breathing cycle [14, 15]. To cope with the non-linearity of the intratidal CRS under the dynamic conditions of mechanical ventilation, the gliding-SLICE method [16, 17] was introduced, enhancing the classical SLICE method [18, 19]. To evaluate the intratidal CRS with the enhanced gliding-SLICE method, the pressure-volume curve is subdivided into several volume steps, and the volume-dependent compliance is calculated on the base of data points within a certain volume range (‘slice’) around the current step via multiple linear regression analysis (Fig. 1). The resulting compliance-volume curve can then be classified as follows: an increasing compliance profile is interpreted to indicate intratidal recruitment, suggesting a PEEP increase. A decreasing compliance profile indicates overdistension, suggesting a PEEP decrease. A horizontal compliance profile is assumed to be preferable as, it does not indicate either unwanted condition. Combinations of these three basic compliance profiles may be observed [17] (Fig. 1). A previously described decision support system with a graphical user interface implemented the gliding-SLICE method in a user-friendly tool to recommend at the bedside individualized PEEP titration during fully controlled ventilation [21].

Fig. 1
figure 1

Intratidal compliance profile analysis during a single breathing cycle according to the gliding-SLICE method [20]. The tidal pressure-volume curve is divided into 21 equidistant slices. For each slice, the compliance profile is determined based on multiple linear regression analysis and matched to the respective tidal volume. The resulting intratidal compliance curves were classified into six different compliance profiles (H = horizontal compliance profile, I/IH = increasing compliance profile, D/HD = decreasing compliance profile, IHD = mixed compliance profiles)

The primary hypothesis of this randomized controlled clinical trial was that individualized PEEP titration, based on analysis of the intratidal compliance profile, would improve the frequency of preferable compliance profiles and ameliorate respiratory system mechanics and regional ventilation during perioperative fully controlled ventilation, compared to a non-personalized PEEP ventilation technique. We determined the frequencies of nonlinear intratidal compliance (CRS) profiles and measured regional ventilation, respiratory mechanics and hemodynamic variables in 60 consecutive fully controlled ventilated patients undergoing otorhinolaryngeal surgery.

Methods

Ethics, consent and permission

The study was approved by the Ethics Committee of the University Medical Center of Freiburg (vote # 268/15) on June 29, 2015 and registered at the German Register for Clinical Trials (DRKS00008924). This study adhered to the CONSORT guidelines.

Study design and patient population

After obtaining written informed consent from the participants, we studied respiratory mechanics, hemodynamic variables, and regional ventilation in 60 consecutive patients with American Society of Anesthesiologists (ASA) physical status I-III, who underwent otorhinolaryngeal surgery at the Medical Center of the University of Freiburg, Germany. The study was performed as a prospective parallel-arm, randomized controlled trial with an allocation ratio of 1:1. Randomization was carried out in blocks of 30 by a computer-generated allocation sequence. Participants were enrolled and assigned to the interventions by a study-related anesthetist. The exclusion criteria were ASA physical status > III, age < 18 years, pregnancy, emergency procedure, cardiac pacemaker and other active implants, obesity (body mass index ≥30 kg·m− 2), a history of pulmonary disease, laparoscopic surgery, or refusal to participate.

Procedure

After primary recruitment and preoperative evaluation, the patients received routine monitoring (electrocardiography, SpO2 and noninvasive blood pressure measurement; Infinity Delta XL, Dräger Medical, Lübeck, Germany). After preoxygenation to an expiratory fraction of oxygen of 0.8, anesthesia was induced and maintained as total intravenous anesthesia with a continuous infusion of propofol (Propofol 1%; Fresenius Kabi, Bad Homburg, Germany; target-controlled infusion, effect site target concentration for induction: 6–8 μg·mL− 1; effect site target concentration for maintenance: 3–5 μg·mL− 1, Agilia, Schnider Model; Fresenius Kabi) and remifentanil (TEVA GmbH, Ulm, Germany; induction: 1–2 μg·kg− 1, maintenance: 0.15–0.3 μg·kg− 1·min− 1). During the study protocol, a Bispectral Index™ (BIS™) monitoring (Medtronic, Minneapolis, USA) was used as an additional monitor of anesthesia depth (BIS value target 40–60). Tracheal intubation was facilitated with 0.15 mg·kg− 1 predicted body weight [22] iv cisatracurium (Fresenius Kabi). Potential hypotension, defined as mean arterial pressure < 65 mmHg, was treated with a continuous norepinephrine infusion (0.03–0.2 μg·kg− 1·min− 1). Volume requirements were addressed individually, according to clinical judgement, with a crystalloid solution (Jonosteril; Fresenius Kabi). For tracheal intubation, we used tracheal tubes with low pressure cuffs, with an internal diameter of 7.0–7.5 mm for women and 8.0 mm for men (Mallinckrodt Hallo-Contour; Covidien, Neustadt an der Donau, Germany). All patients were ventilated in the volume-controlled mode with a tidal volume (VT) of 7 mL·kg− 1 predicted body weight. Ventilation frequency was set to maintain an end-tidal carbon dioxide partial pressure between 35 and 40 mmHg. In all patients, the initial PEEP was set to 5 cmH2O. Following these baseline measurements, the randomization was disclosed. In the control group, the PEEP was maintained for the whole procedure. In the intervention group, the PEEP was adjusted dynamically according to the recommendations resulting from the intratidal compliance profile analysis (see below).

Gliding-SLICE

To calculate nonlinear intratidal CRS profiles via the gliding-SLICE method, we chose 21 equidistant slices as a tradeoff between calculation effort and reasonable resolution. The resulting intratidal compliance curves were classified into six different compliance profiles, as described earlier [19, 20, 23]. In brief, a second-order polynomial was fitted into the compliance-volume curve, and the resulting segment of a parabola was assumed to represent the compliance-volume curve in a filtered form. If the segment showed an increase of more than 20% of the compliance maximum, the profile was classified as containing an increasing part. A segment decreasing by more than 20% of the compliance maximum was classified as containing a decreasing part. A segment containing the angular point of the parabola was classified as containing the horizontal part. A compliance profile with less than 20% change was classified as horizontal (Fig. 1) [21]. The decision support system suggested a PEEP increase of 2 cmH2O in the case of a merely increasing compliance profile, 1 cmH2O in the case of an increasing compliance profile with a horizontal component, a PEEP decrease of 2 cmH2O for a merely decreasing compliance profile, and 1 cmH2O in the case of a decreasing compliance profile with horizontal component. A merely horizontal compliance profile resulted in the suggestion to maintain PEEP as it was.

Electrical impedance tomography

Regional ventilation was measured via electrical impedance tomography (EIT) (PulmoVista 500, Dräger Medical) every 10 min for a duration of 2 min. EIT recordings were evaluated offline using software developed in Matlab (MATLAB R2014a, The Mathworks Inc., Natick, MA, USA). As a first step, the relevant lung areas were determined for each patient by applying the lung area estimation method [24, 25] to the raw EIT data. The functional region of interest was selected by deleting all pixels with an impedance change smaller than 20% of the maximum tidal impedance change. The remaining pixels were mirrored to compensate for potential atelectatic areas. The obtained lung area was then applied to all the recorded raw EIT images. After this preprocessing, the functional impedance images were generated by subtracting the frames corresponding to the start of inspiration from the frames corresponding to the end of inspiration. These functional images (f-EIT) thus represented the distribution of the tidal volume for each breath. To assess potential changes in regional ventilation, tidal variation as well as a gain and loss calculations were performed and compared between the two groups. The gain and loss calculations were based on subtracting the functional impedance images of different time points to directly compare differences in ventilation between them. In this study, the averaged f-EIT images of the first EIT recording (baseline measurement, prior to the surgical procedure) and the averaged f-EIT images of the last EIT recording (after the surgical procedure was finished) were subtracted for each patient. The resulting differential images were split into ventral and dorsal parts and the number of positive (‘gain’) and negative (‘loss’) pixels were calculated for each such region. A gain was represented by the number of pixels that exhibited an increase in aeration in the last measured EIT sequence compared to the first (baseline) measured EIT sequence and loss was shown by a decrease in aeration. The results were compared between the two different groups. The change in tidal volume (ΔVT) was calculated as the difference between gain (TVG) and loss (TVL) (ΔVT = TVG - TVL) for the previously defined ventral (ΔVT,v) and dorsal (ΔVT,d) lung areas. This provided a measure for changes in regional ventilation. If this difference was positive, we assumed an increase in regional ventilation in the respective lung area, whereas a negative difference indicated a decrease in regional ventilation [26].

Tidal variation (impedance distribution) is the percentage of tidal volume going to the ventral (TVv) and the dorsal areas (TVd). This was calculated for all the functional impedance images using Eq. 1,

$$ {TV}_v=\frac{\sum {x}_{i,v}}{\sum {x}_i}\ \mathrm{or}\ {TV}_d=\frac{\sum {x}_{i,d}}{\sum {x}_i} $$
(1)

where xi,v are the impedance values in the ventral region, xi,d the impedance values in the dorsal region and xi the sum of all impedance values of the f-EIT under consideration. Tidal variation was calculated for each averaged f-EIT image of each 2-min EIT recording.

End points and data collection

The frequency of each type of nonlinear intratidal CRS profile (measured using the gliding-SLICE method) was the primary endpoint of this study. The secondary endpoints were regional ventilation (ventral and dorsal ventilation distribution, ventral and dorsal gain and loss and tidal variation), the respiratory system variables (peak inspiratory pressure [PIP], PPlat, mean tracheal pressure [Pmean], PEEP) and hemodynamic variables (systolic blood pressure [BPsys], diastolic blood pressure [BPdias], heart rate and mean arterial pressure [MAP]). The intratidal compliance profiles, respiratory, and hemodynamic variables were recorded continuously during the study protocol. EIT measurements were performed every 10 min for a duration of 2 min.

Sample size calculation and statistical evaluation

No data are available concerning the variance of frequencies of compliance profiles. Therefore, we based our sample size calculation on estimation of a general standardized effect size e, being the quotient of differences in means and standard deviation. With regard to our approach, which adapted PEEP according to the measured compliance profile, we assumed a large effect size and therefore chose e = 0.8 [27]. In regard to the trial design (unpaired test conditions) and an assumed e of 0.8, 50 patients were required to reach a test power of 0.8 with a desired level of significance of 0.05.

To compensate for potentially incomplete data sets, 60 patients were recruited. Data are presented as means (standard deviation). Differences between the two groups were assessed with the unpaired Students t-test. Statistical significance was considered for p < 0.05. Shapiro–Wilk tests were used to confirm that the assumed normal distribution could not be rejected. For data not normally distributed, differences between the two groups were assessed with Mann–Whitney U tests.

Results

Patients were enrolled from November 5, 2015 to January 29, 2016. In total, 60 patients were included. Twelve patients had to be excluded due to incomplete data sets (Fig. 2). During the study protocol, no adverse or serious events occurred. Age, gender, ASA physical status, predicted body weight, actual body weight and body mass index were comparable between the two groups (Table 1).

Fig. 2
figure 2

Flow diagram of the study population

Table 1 Patients characteristics (n = 48)

Respiratory and hemodynamic variables

In 12 patients in the intervention group (48%), the PEEP was adjusted according to the intratidal compliance profile analysis. In 11 patients (44%), the PEEP was increased, as the corresponding compliance profile analysis showed increasing compliance profiles. In 7 of these patients (28%), the PEEP was thenceforward held constant. In 3 of the patients in the intervention group (12%), the PEEP was adjusted twice. In 2 patients (8%), the PEEP was adjusted three times. PEEP was higher in the intervention group compared to the control group [control: 5.0 (0.2) cmH2O; intervention: 5.8 (1.1) cmH2O, p < 0.001; range control: 5.0–5.0 cmH2O; range intervention: 3.9–8.5 cmH2O]. In total, PEEP was adapted in 12 patients in the intervention group (48%). These individualized PEEP adaptations had no significant effect on the other measured respiratory system or hemodynamic variables (Table 2). The frequencies of nonlinear intratidal CRS profiles showed no significant difference between the two groups (Table 3).

Table 2 Respiratory and hemodynamic variables
Table 3 Frequencies of compliance profiles from 48 patients

EIT measurements

The regional impedance distribution showed no significant difference in ventilation distribution between the two groups (Table 4). The gain and loss calculations showed a significant decrease in loss of ventral regional ventilation between the two groups [loss of ventral regional ventilation of 41.0 (16.s3)% in the control group and 29.7 (16.8)% in the intervention group, p = 0.039]. In the dorsal lung area, the gain in regional ventilation was higher in the intervention group [14.3 (11.9)%] than in the control group [24.6 (13.0)%, p = 0.013] (Fig. 3). In the intervention group, the loss of dorsal regional ventilation was less pronounced [16.4 (12.7)%] than in the control group [25.9 (13.9)%, p = 0.028] (Table 4). TVv and TVd showed no significant difference between the two groups. ΔVT,v indicated a lower difference between gain and loss in the intervention than in the control group in the ventral lung area (ΔVT,v [control group] = − 22.2 (31.1)%; ΔVT,v [intervention group] = − 0.4 (34.2)%, p = 0.044). ΔVT,d indicated a lower difference between gain and loss in the intervention than in the control group in the dorsal lung area (ΔVT,d [control group] = − 11.6 (24.6)%; ΔVT,d [intervention group] = 8.25 (25.4)%, p = 0.017) (Table 4).

Table 4 Measurements of regional ventilation
Fig. 3
figure 3

Functional impedance images (f-EIT) of two respective exemplary patients. According to the study protocol, volume-controlled ventilation was started with a PEEP of 5 cmH2O. In the exemplary patient in the intervention group (a-c), the PEEP was then increased to 7 cmH2O as the intratidal compliance profile analysis indicated a merely increasing compliance profile. In the patient in the control group (d-f), the PEEP was maintained at 5 cmH2O. f-EIT images were generated by subtracting the frames corresponding to the start of inspiration from the frames corresponding to the end of inspiration. a f-EIT image of the exemplary patient of the intervention group initially ventilated with PEEP 5 cmH2O; b f-EIT image of the exemplary patient of the intervention group during the last EIT measurement after the surgical procedure was finished; c Illustration of gain (red) and loss (blue) for the patient in the intervention group; d f-EIT image of the exemplary patient of the control group during baseline measurements; e f-EIT image of the exemplary patient of the control group during the last EIT measurement after the surgical procedure was finished; f Illustration of gain (red pixels) and loss (blue pixels) for the patient in the control group. Gain represents the amount of pixels that exhibited an increase in ventilation in the end compared to the beginning and loss the decrease in ventilation accordingly

Discussion

In this study, we compared the effects of individualized PEEP titration performed according to bedside analysis of the frequencies of nonlinear intratidal CRS profiles (measured using the gliding-SLICE method). The main finding is that the individualized PEEP titration improved regional ventilation without affecting impedance distribution and the respiratory or hemodynamic variables negatively.

Respiratory and hemodynamic variables

Besides PEEP, none of the respiratory and hemodynamic variables differed between the two patient groups. PEEP is generally associated with recruitment and one might expect that CRS increases with increasing PEEP. However, in agreement with earlier studies [14, 28] CRS remained unchanged. In our study, patients showed respiratory system mechanics that were mostly characterized by a horizontal compliance profile, and consequently PEEP adaptations were performed less frequently than expected. It follows that the observed improvement in regional ventilation may have increased CRS, if the studied patient group had included more patients with impaired respiratory system mechanics or who underwent surgical procedures associated with an increased risk for altered respiratory functions (e.g., laparoscopic surgery). Since this is the first study in which we applied individualized PEEP titration according to compliance profile analysis, we did not include patients at risk for impaired respiratory system performance. One might speculate further that the comparably high alveolar recruitment in the studied patients was the reason we did not find significant differences in CRS. This hypothesis can be supported by two clinical trials that provided preliminary investigations of the gliding-SLICE method [14, 28]. In both studies, lower levels of PEEP (such as 5 and 7 cmH2O) did not prevent from CRS profiles indicating recruitment/derecruitment. In both studies, intratidal compliance profile analysis was used as a bedside measurement for predefined PEEP settings. In the present study, this analysis was used to guide PEEP titration individually. One might also speculate that the longer duration of the surgical procedure (mean duration of surgery of 120 min and 184 min vs. 83.2 min (control group) and 87.5 min (intervention group) in the present study) [14, 28] led to a more pronounced impairment of respiratory system mechanics and thus of intratidal CRS profiles. In the present study, obesity was an exclusion criterion, whereas in one of the previous studies [14], obese patients were included. Further studies are needed to provide more detailed information about the impact of an individualized PEEP titration strategy based on the gliding-SLICE method on respiratory function in patients with impaired respiratory system mechanics.

By increasing the intrathoracic pressure, PEEP was shown to affect the cardiac performance by altering the left ventricular preload, afterload, and cardiac contractility [29]. Previous studies found that, in case of increasing intratidal compliance profiles, a small increase in PEEP led to ventilation with horizontal compliance [14, 28]. Since the overall increase of PEEP in our intervention group was comparably low, it is not surprising that our individualized PEEP titration had no effect on the measured hemodynamic variables.

Previously described techniques for titrating PEEP (the decremental PEEP trial [30], dead space fraction [31], indices of regional ventilation [32,33,34], esophageal pressure [35], or other imaging techniques [36]), require additional equipment, involve an additional burden for the patient, or may per se not be available at the bedside. The techniques based on the determination of best PEEP from static respiratory system variables, such as the static pressure-volume curve, did not contribute to the dynamic intratidal changes in respiratory system mechanics [37]. Moreover, they require a prolonged maneuver during which the patient is not sufficiently ventilated. During a decremental PEEP trial, adequate ventilation is warranted however, to identify the PEEP for maximum CRS, the optimal PEEP must necessarily be exceeded during the maneuver. Thus, previously described PEEP titration methods often bear the risk of overdistension and cannot be applied continuously. By contrast, PEEP titration based on the intratidal compliance profile does not require a maneuver, may be applied on a breath-by-breath analysis, and is applicable for consecutive PEEP adjustment.

Regional ventilation

Even in patients without impaired respiratory function, induction of general anesthesia and consecutive mechanical ventilation bear the risk of atelectrauma [38]. As a noninvasive, radiation-free method, EIT can be used to monitor regional ventilation and the formation of atelectasis [39].

Comparing the baseline measurements (the EIT sequence before the surgical procedure) and the last EIT sequence (after the end of the surgical procedure) with gain and loss calculations showed a significant increase in aeration in the intervention group. This is not surprising, since PEEP was higher in the intervention group, which led to an increase in aeration [40]. The detected changes in regional gain and loss calculations might suggest that the individualized PEEP titration strategy, according to the gliding-SLICE method, reduced the loss of ventilation in the dependent lung areas. However, the detected effect was very limited; the frequencies of the compliance profiles, the TVv and TVd values, and the respiratory system mechanics were comparable.

Tidal variation did not differ significantly between the two groups. The larger part of ventilation remained for both groups in the ventral region of the lung at all times. Again, this is expected for mechanically ventilated patients [41]. However, one has to keep in mind that a shift in tidal variation from ventral to dorsal regions would indicate recruitment. This would be very unlikely in lung-healthy patients, since their lungs are already very well recruited.

It might seem that the results from our gain and loss calculations contradict the findings for tidal variation development. However, we found almost equal gain in both the ventral and the dorsal areas for both groups. We argue that this does not necessarily change the ventilation fraction in these parts. Consider as an example an hourglass at a certain time point when more sand is in the top compartment than in the bottom compartment. If the amount of sand in the top compartment is increased and the diameter of the connecting tube is increased accordingly, there would be more sand in both compartments, but the fraction of sand in the top compartment would not change. In contrast to this analogy, the tidal volume was held constant in both groups, but with increasing PEEP the residual capacity of the lung was increased as well [42]. We would also speculate that redistribution of volume, either based on pendelluft effects or from areas outside our observation plane, might also have contributed to the surplus in aeration.

Limitations of the study

We did not perform arterial blood gas analyses or invasive blood pressure measurement to evaluate hemodynamic performance with a higher temporal resolution. Placing an arterial line was not part of our standard treatment for the patients included in this study. Since the intention of our study was to investigate the impact of a comparable new individualized PEEP titration strategy in a non-injured respiratory system, we did not include patients with impaired respiratory function. Based on our earlier study, we expected a large effect size, without having any data on variability of the frequencies of compliance profiles available, however. Therefore, the study was underpowered for detecting differences in frequencies of compliance profiles between the two groups. This may have been caused by our choice of an approach utilizing a general standardized effect size for the sample size calculation. This may limit the interpretation of our results.

Further studies are required to investigate the potential impact of PEEP titration based on bedside analysis of nonlinear intratidal compliance on the respiratory system mechanics in patients prone to impaired respiratory function.

Conclusions

This is the first study to investigate regional ventilation during PEEP titration guided by intratidal compliance profile analysis in patients. Our individualized PEEP titration strategy led to an improvement in global aeration gain. Bedside analysis of the nonlinear intratidal mechanics of the respiratory system did not improve respiratory system mechanics and compliance profiles. The observed global increase in aeration indicated by the calculations of regional gain and loss and change in tidal volume might just indicate the slight increase in aeration due to the small PEEP increase in the intervention group.

Availability of data and materials

The datasets used and analyzed during the current study are available from the corresponding author on request. Please note that EIT data files require large memory. A separate data transfer service will be used to transfer EIT data files.

Abbreviations

ASA:

American Society of Anesthesiologists

BPdias :

Diastolic blood pressure

BPsys :

Systolic blood pressure

CRS :

Compliance of the respiratory system

Cstat :

Quasi-static compliance of the respiratory system

EIT:

Electrical impedance tomography

EITh :

Mean thoracic electrical impedance

FeO2 :

Expiratory oxygen concentration

FiO2 :

Inspiratory oxygen concentration

I:E:

Ratio of inspiratory time to expiratory time

MAP:

Mean arterial pressure

PEEP:

Positive end-expiratory pressure

PIP:

Peak inspiratory pressure

Pmean :

Mean airway pressure

PPlat :

Plateau pressure

SpO2 :

Peripheral oxygen saturation (pulse oximetry)

VF:

Ventilation frequency

VT :

Tidal volume

References

  1. Neto AS, Hemmes SNT, Barbas CSV, Beiderlinden M, Fernandez-Bustamante A, Futier E, et al. Association between driving pressure and development of postoperative pulmonary complications in patients undergoing mechanical ventilation for general anaesthesia: a meta-analysis of individual patient data. Lancet Respir Med. 2016;4:272–80. https://doi.org/10.1016/S2213-2600(16)00057-6.

    Article  PubMed  Google Scholar 

  2. Futier E, Constantin J-M, Paugam-Burtz C, Pascal J, Eurin M, Neuschwander A, et al. A trial of intraoperative low-tidal-volume ventilation in abdominal surgery. N Engl J Med. 2013;369:428–37. https://doi.org/10.1056/NEJMoa1301082.

    Article  CAS  PubMed  Google Scholar 

  3. Loring SH, Malhotra A. Driving pressure and respiratory mechanics in ARDS. N Engl J Med. 2015;372:776–7. https://doi.org/10.1056/NEJMe1414218.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  4. Amato MBP, Meade MO, Slutsky AS, Brochard L, Costa ELV, Schoenfeld DA, et al. Driving pressure and survival in the acute respiratory distress syndrome. N Engl J Med. 2015;372:747–55. https://doi.org/10.1056/NEJMsa1410639.

    Article  CAS  PubMed  Google Scholar 

  5. Ward NS, Lin DY, Nelson DL, Houtchens J, Schwartz WA, Klinger JR, et al. Successful determination of lower inflection point and maximal compliance in a population of patients with acute respiratory distress syndrome. Crit Care Med. 2002;30:963–8.

    Article  Google Scholar 

  6. Servillo G, de Robertis E, Maggiore S, Lemaire F, Brochard L, Tufano R. The upper inflection point of the pressure-volume curve. Influence of methodology and of different modes of ventilation. Intensive Care Med. 2002;28:842–9. https://doi.org/10.1007/s00134-002-1293-7.

    Article  PubMed  Google Scholar 

  7. Hess DR. Recruitment maneuvers and PEEP titration. Respir Care. 2015;60:1688–704. https://doi.org/10.4187/respcare.04409.

    Article  PubMed  Google Scholar 

  8. Suter PM, Fairley B, Isenberg MD. Optimum end-expiratory airway pressure in patients with acute pulmonary failure. N Engl J Med. 1975;292:284–9. https://doi.org/10.1056/NEJM197502062920604.

    Article  CAS  PubMed  Google Scholar 

  9. Lemaire F, Simoneau G, Harf A, Rivara D, Teisseire B, Atlan G, Rapin M. Tatic pulmonary pressure-volume (P-V) curve, positive end-expiratory pressure (PEEP) ventilation and gas exchange in acute respiratory failure (ARF). In: American Review of Respiratory Disease; 1979. p. 328.

    Google Scholar 

  10. O'Keefe GE, Gentilello LM, Erford S, Maier RV. Imprecision in lower "inflection point" estimation from static pressure-volume curves in patients at risk for acute respiratory distress syndrome. J Trauma. 1998;44:1064–8.

    Article  CAS  Google Scholar 

  11. Matamis D, Lemaire F, Harf A, Brun-Buisson C, Ansquer JC, Atlan G. Total respiratory pressure-volume curves in the adult respiratory distress syndrome. Chest. 1984;86:58–66.

    Article  CAS  Google Scholar 

  12. Mercat A, Richard J-CM, Vielle B, Jaber S, Osman D, Diehl J-L, et al. Positive end-expiratory pressure setting in adults with acute lung injury and acute respiratory distress syndrome: a randomized controlled trial. JAMA. 2008;299:646–55. https://doi.org/10.1001/jama.299.6.646.

    Article  CAS  PubMed  Google Scholar 

  13. Pintado M-C, de Pablo R, Trascasa M, Milicua J-M, Rogero S, Daguerre M, et al. Individualized PEEP setting in subjects with ARDS: a randomized controlled pilot study. Respir Care. 2013;58:1416–23. https://doi.org/10.4187/respcare.02068.

    Article  PubMed  Google Scholar 

  14. Wirth S, Baur M, Spaeth J, Guttmann J, Schumann S. Intraoperative positive end-expiratory pressure evaluation using the intratidal compliance-volume profile. Br J Anaesth. 2015;114:483–90. https://doi.org/10.1093/bja/aeu385.

    Article  CAS  PubMed  Google Scholar 

  15. Zhao Z, Guttmann J, Möller K. Assessment of a volume-dependent dynamic respiratory system compliance in ALI/ARDS by pooling breathing cycles. Physiol Meas. 2012;33:N61–7. https://doi.org/10.1088/0967-3334/33/8/N61.

    Article  PubMed  Google Scholar 

  16. Schumann S, Stahl C, Steinmann D, Möller K, Guttmann J. The gliding-SLICE method: an enhanced tool for estimation of intratidal respiratory mechanics. Crit Care. 2007;11:P204. https://doi.org/10.1186/cc5364.

    Article  PubMed Central  Google Scholar 

  17. Schumann S, Vimlati L, Kawati R, Guttmann J, Lichtwarck-Aschoff M. Analysis of dynamic intratidal compliance in a lung collapse model. Anesthesiology. 2011;114:1111–7. https://doi.org/10.1097/ALN.0b013e31820ad41b.

    Article  PubMed  Google Scholar 

  18. Guttmann J, Eberhard L, Fabry B, Zappe D, Bernhard H, Lichtwarck-Aschoff M, et al. Determination of volume-dependent respiratory system mechanics in mechanically ventilated patients using the new SLICE method. Technol Health Care. 1994;2:175–91. https://doi.org/10.3233/THC-1994-2302.

    Article  CAS  PubMed  Google Scholar 

  19. Mols G, Brandes I, Kessler V, Lichtwarck-Aschoff M, Loop T, Geiger K, Guttmann J. Volume-dependent compliance in ARDS: proposal of a new diagnostic concept. Intensive Care Med. 1999;25:1084–91.

    Article  CAS  Google Scholar 

  20. Schumann S, Burcza B, Haberthür C, Lichtwarck-Aschoff M, Guttmann J. Estimating intratidal nonlinearity of respiratory system mechanics: a model study using the enhanced gliding-SLICE method. Physiol Meas. 2009;30:1341–56. https://doi.org/10.1088/0967-3334/30/12/004.

    Article  PubMed  Google Scholar 

  21. Buehler S, Lozano-Zahonero S, Schumann S, Guttmann J. Monitoring of intratidal lung mechanics: a graphical user Interface for a model-based decision support system for PEEP-titration in mechanical ventilation. J Clin Monit Comput. 2014;28:613–23. https://doi.org/10.1007/s10877-014-9562-x.

    Article  CAS  PubMed  Google Scholar 

  22. Devine BJ. Gentamicin therapy. Drug Intell Clin Pharm. 1974;8:650–5.

  23. Mols G, Priebe H-J, Guttmann J. Alveolar recruitment in acute lung injury. Br J Anaesth. 2006;96:156–66. https://doi.org/10.1093/bja/aei299.

    Article  CAS  PubMed  Google Scholar 

  24. Frerichs I, Amato MBP, van Kaam AH, Tingay DG, Zhao Z, Grychtol B, et al. Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group. Thorax. 2017;72:83–93. https://doi.org/10.1136/thoraxjnl-2016-208357.

    Article  PubMed  Google Scholar 

  25. Zhao Z, Möller K, Steinmann D, Guttmann J. Determination of lung area in electrical impedance tomography images. Crit Care. 2009;13:P51. https://doi.org/10.1186/cc7215.

    Article  PubMed Central  Google Scholar 

  26. Luepschen H, Meier T, Grossherr M, Leibecke T, Karsten J, Leonhardt S. Protective ventilation using electrical impedance tomography. Physiol Meas. 2007;28:S247–60. https://doi.org/10.1088/0967-3334/28/7/S18.

    Article  CAS  PubMed  Google Scholar 

  27. Sullivan GM, Feinn R. Using effect size-or why the P value is not enough. J Grad Med Educ. 2012;4:279–82. https://doi.org/10.4300/JGME-D-12-00156.1.

    Article  PubMed  PubMed Central  Google Scholar 

  28. Wirth S, Kreysing M, Spaeth J, Schumann S. Intraoperative compliance profiles and regional lung ventilation improve with increasing positive end-expiratory pressure. Acta Anaesthesiol Scand. 2016;60:1241–50. https://doi.org/10.1111/aas.12767.

    Article  CAS  PubMed  Google Scholar 

  29. Pinsky MR. The hemodynamic consequences of mechanical ventilation: an evolving story. Intensive Care Med. 1997;23:493–503. https://doi.org/10.1007/s001340050364.

    Article  CAS  PubMed  Google Scholar 

  30. Gernoth C, Wagner G, Pelosi P, Luecke T. Respiratory and haemodynamic changes during decremental open lung positive end-expiratory pressure titration in patients with acute respiratory distress syndrome. Crit Care. 2009;13:R59. https://doi.org/10.1186/cc7786.

    Article  PubMed  PubMed Central  Google Scholar 

  31. Fengmei G, Jin C, Songqiao L, Congshan Y, Yi Y. Dead space fraction changes during PEEP titration following lung recruitment in patients with ARDS. Respir Care. 2012;57:1578–85. https://doi.org/10.4187/respcare.01497.

    Article  PubMed  Google Scholar 

  32. Lowhagen K, Lundin S, Stenqvist O. Regional intratidal gas distribution in acute lung injury and acute respiratory distress syndrome assessed by electric impedance tomography. Minerva Anestesiol. 2010;76:1024–35.

    CAS  PubMed  Google Scholar 

  33. Heines SJH, Strauch U, van de Poll MCG, Roekaerts PMHJ, Bergmans DCJJ. Clinical implementation of electric impedance tomography in the treatment of ARDS: a single Centre experience. J Clin Monit Comput. 2019;33:291–300. https://doi.org/10.1007/s10877-018-0164-x.

    Article  PubMed  Google Scholar 

  34. He X, Jiang J, Liu Y, Xu H, Zhou S, Yang S, et al. Electrical Impedance Tomography-guided PEEP Titration in Patients Undergoing Laparoscopic Abdominal Surgery. Medicine (Baltimore). 2016;95:e3306. https://doi.org/10.1097/MD.0000000000003306.

    Article  Google Scholar 

  35. Talmor D, Sarge T, Malhotra A, O'Donnell CR, Ritz R, Lisbon A, et al. Mechanical ventilation guided by esophageal pressure in acute lung injury. N Engl J Med. 2008;359:2095–104. https://doi.org/10.1056/NEJMoa0708638.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  36. Gattinoni L, Caironi P, Valenza F, Carlesso E. The role of CT-scan studies for the diagnosis and therapy of acute respiratory distress syndrome. Clin Chest Med. 2006;27:559–70. https://doi.org/10.1016/j.ccm.2006.06.002 abstract vii.

    Article  PubMed  Google Scholar 

  37. Stahl CA, Möller K, Schumann S, Kuhlen R, Sydow M, Putensen C, Guttmann J. Dynamic versus static respiratory mechanics in acute lung injury and acute respiratory distress syndrome. Crit Care Med. 2006;34:2090–8. https://doi.org/10.1097/01.CCM.0000227220.67613.0D.

    Article  PubMed  Google Scholar 

  38. Brismar B, Hedenstierna G, Lundquist H, Strandberg A, Svensson L, Tokics L. Pulmonary densities during anesthesia with muscular relaxation--a proposal of atelectasis. Anesthesiology. 1985;62:422–8.

    Article  CAS  Google Scholar 

  39. van der Burg PS, Miedema M, de Jongh FH, van Kaam AH. Unilateral atelectasis in a preterm infant monitored with electrical impedance tomography: a case report. Eur J Pediatr. 2014;173:1715–7. https://doi.org/10.1007/s00431-014-2399-y.

    Article  PubMed  Google Scholar 

  40. Frerichs I, Dargaville PA, Dudykevych T, Rimensberger PC. Electrical impedance tomography: a method for monitoring regional lung aeration and tidal volume distribution? Intensive Care Med. 2003;29:2312–6. https://doi.org/10.1007/s00134-003-2029-z.

    Article  PubMed  Google Scholar 

  41. Radke OC, Schneider T, Heller AR, Koch T. Spontaneous breathing during general anesthesia prevents the ventral redistribution of ventilation as detected by electrical impedance tomography: a randomized trial. Anesthesiology. 2012;116:1227–34. https://doi.org/10.1097/ALN.0b013e318256ee08.

    Article  PubMed  Google Scholar 

  42. Satoh D, Kurosawa S, Kirino W, Wagatsuma T, Ejima Y, Yoshida A, et al. Impact of changes of positive end-expiratory pressure on functional residual capacity at low tidal volume ventilation during general anesthesia. J Anesth. 2012;26:664–9. https://doi.org/10.1007/s00540-012-1411-9.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

This project has not received any funding. The article processing charge was funded by the German Research Foundation (DFG) and the University of Freiburg in the funding program Open Access Publishing.

Author information

Authors and Affiliations

Authors

Contributions

Planning the study: SS, SW. Conduction of the study: JG, SW. Data analysis: JW, SLZ, SB, SS, SW. Drafting the article: JW, JS, SS, SW. Revising the article for important intellectual content: All authors. All authors have read and approved the manuscript.

Corresponding author

Correspondence to Jonas Weber.

Ethics declarations

Ethics approval and consent to participate

The study was approved by the Ethics Committee of the University Medical Centre of Freiburg (Engelbergstr. 21, 79106 Freiburg, Germany, Ethical Committee N° 268/15) on 29th June 2015 (Chairperson Prof. Dr. R. Korinthenberg). Written informed consent was obtained from all participants.

Consent for publication

Not applicable.

Competing interests

JW, JG, JS, SLZ, SB and SW declare no conflicts of interest. SS. has a consulting contract with Gründler GmbH, Freudenstadt (no relationship to this study).

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Weber, J., Gutjahr, J., Schmidt, J. et al. Effect of individualized PEEP titration guided by intratidal compliance profile analysis on regional ventilation assessed by electrical impedance tomography – a randomized controlled trial. BMC Anesthesiol 20, 42 (2020). https://doi.org/10.1186/s12871-020-00960-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12871-020-00960-9

Keywords