Skip to main content

VivaSight™ single-lumen tube guided bronchial blocker placement for one-lung ventilation in a patient with a tracheal tumor under video-assisted transthoracic surgery: a case report

Abstract

Background

Video-assisted transthoracic surgery (VATS) is a minimally invasive procedure that has been reported as a valid method for tracheal resection and reconstruction. However, for patients with tracheal tumors, one-lung ventilation during VATS is difficult to achieve, and utilizing a double-lumen tube is not applicable in these types of situations. When using a bronchial blocker, a fiberoptic bronchoscope is required to verify the position of bronchial blocker, though the repeated use of the fiberoptic bronchoscope increases the risk of tumor rupture and hemorrhage.

Case presentation

We report a case with a middle tracheal tumor received tracheal resection and reconstruction under VATS, in which VivaSight™ single-lumen tube guided bronchial blocker placement was used for achieving one-lung ventilation. The VivaSight™ single-lumen tube can provide real-time and continuous monitoring of the position of bronchial blocker. Moreover, it does not require the aid of fiberoptic bronchoscopy.

Conclusions

VivaSight™ single-lumen tube combined with a bronchial blocker is a feasible choice for one-lung ventilation in this type of surgery.

Peer Review reports

Background

Tracheal resection and reconstruction are often used for treating malignant tracheal tumors, which are difficult procedures for both the thoracic surgeon and anesthesiologist involved. Video-assisted transthoracic surgery (VATS) is a minimally invasive procedure that has been reported as a valid method for tracheal resection and reconstruction [1, 2]. However, for patients with tracheal tumors, one-lung ventilation during VATS is difficult to achieve. A double-lumen tube (DLT) is not indicated in this situation, because it can destroy the tumor and lead to the risk of bleeding [3, 4]. When using a bronchial blocker, a fiberoptic bronchoscope is required to verify the position of bronchial blocker, though the repeated use of the fiberoptic bronchoscope increases the risk of tumor rupture and hemorrhage. VivaSight™ single-lumen tube (SLT) (ETView Ltd., Misgav, Israel) is the new generation of endotracheal tubes incorporating a high-resolution imaging camera and a light source in its tip. It can guide the placement of bronchial blocker without the aid of fiberoptic bronchoscopy. Theoretically, it makes placement of a bronchial blocker faster and provides continuous visualization. We report a case of a middle tracheal tumor in which VivaSight™ SLT guided bronchial blocker placement was used for one-lung ventilation under VATS.

Case presentation

A 70-year-old, 54-kg male presented with cough and blood-stained sputum. A computed tomography (CT) scan of the chest revealed a tracheal lesion in the middle trachea (Shown in Fig. 1). Bronchoscopy showed a tumor encroaching into the left tracheal wall of the middle trachea. A biopsy was positive for an adenoid cystic carcinoma of the trachea. Routine laboratory investigations were normal. The patient’s electrocardiogram showed changes of ST-T in the anterior lateral wall and the inferior wall. Coronary CT angiography confirmed that the left anterior descending branch was mildly-to-moderately stenosed with atherosclerosis. Cardiac function was at NYHA classification level II. To avoid the stress response of open thoracotomy, the patient was scheduled for tracheal resection and reconstruction under VATS.

Fig. 1
figure 1

Chest computed tomography (CT) revealed a local thickening in the middle trachea

After arrival in the operating room, routine monitoring including electrocardiography, blood pressure, and pulse oximetry were applied. Preoperative vital signs included a blood pressure of 138/82 mmHg, heart rate of 70 beats per minute and pulse oximetry of 99%. Catheterization of the radial artery was performed under local anesthesia for continuous blood pressure monitoring as well as blood gas analysis.

After preoxygenation, anesthesia was induced with intravenous sufentanil (Yichang Humanwell Pharmaceutical Company, China), propofol (AstraZeneca S.P.A., Italy), and cis-atracurium (Hengrui Medicine, Jiangsu, China). Under visual guidance of the imaging camera in the tip, an internal diameter (ID) of 7.5 mm VivaSight™ SLT was intubated through the glottis and placed above the tracheal tumor (Shown in Fig. 2). The tube was then rotated until carina and tumor were both visualized on the monitor simultaneously. A 9F bronchial blocker was placed in the right main bronchus under the guidance of VivaSight™ SLT. The cuff of the bronchial blocker was inflated with the volume necessary to seal the bronchus (8 mL air). (Shown in Fig. 3). General anesthesia was maintained with continuous intravenous infusion of remifentanil (Yichang Humanwell Pharmaceutical Company, China) 0.1–0.15 mcg•kg− 1•min− 1 and propofol (AstraZeneca S.P.A., Italy) 6–8 mg•kg− 1•h− 1. The depth of anesthesia was adjusted according to the Narcotrend index (MonitorTechnik, Bad Bramstedt, Germany). Cis-atracurium was intermittently administered to maintain muscle relaxation by the guidance of TOF-Watch (Organon, Netherlands).

Fig. 2
figure 2

The VivaSight™ SLT was placed above the tracheal tumor under the monitor view. The white arrow refers to the tumor. The black arrow refers to carina

Fig. 3
figure 3

The placement of the bronchial blocker through the monitor of a VivaSight™ SLT

The patient was placed in the left lateral decubitus and the position of the bronchial blocker was continuously monitored. Right video assisted thoracotomy was performed uneventfully to separate the trachea. Right lung collapse was achieved by deflating the cuff of the bronchial blocker and disconnecting the tube from the ventilator just before the surgeon broke the pleura. After a few seconds, the cuff of the bronchial blocker was inflated with the same volume of air and one-lung ventilation was achieved.

After the trachea was well exposed, the bronchial blocker was withdrawn, and a sterile SLT of ID 6.5 mm was placed to the left main bronchus through the incision of the trachea by the surgeon. One-lung ventilation was then performed through this tube. Following previous report [5], the lesioned tracheal was resected. During tracheal anastomosis, the patient was intermittent ventilated through the endobronchial tube, which was inserted from the incision of tracheal by the surgeon. As tracheal anastomosis was not easily performed under VATS. When the surgeon was doing the tracheal anastomosis, the SLT was removed and the ventilation was interrupted. For a while, the SLT was re-inserted and the patient was ventilated to restore oxygenation. Until the completion of tracheal anastomosis, the patient was ventilated again through the VivaSight SLT. After surgery, the patient was transferred to the thoracic ICU with a trachea tube. He was extubated at 24 h post-operatively.

Discussion and conclusions

A different approach was selected for tracheal resection and reconstruction in this case, according to the location of the tracheal lesion. The upper part of the trachea was generally resected from the neck approach, while the procedure in the lower part of the trachea was performed from the thoracic approach [6]. With advances in minimally invasive techniques and devices, VATS resection and reconstruction of the trachea can achieve radical resection of the tumor [7]. Considering that this patient had a history of coronary atherosclerosis, VATS-guided resection and reconstruction of the trachea was chosen to reduce the stress response.

In recent years, VATS guided resection of tracheal tumors has been reported under spontaneous ventilation anesthesia [8]. The advantage of this type of procedure is that it accelerates postoperative recovery. However, the method requires that both surgeon and anesthesiologist have extensive experience with non-intubation VATS. The potential risks include hypoxemia, hypercapnia, uncontrolled coughing and soiling of the airway with blood and secretions. Therefore, we used general anesthesia with tracheal intubation in this patient.

VATS requires a clear exposure of the surgical field. DLT is routinely used to achieve one-lung ventilation, while a bronchial blocker is selected in some special situations, such as pediatric patients or difficult airways [4]. For patients with a tracheal tumor, one-lung ventilation during VATS is difficult to achieve. First, DLT is not indicated in this situation. A tumor in the trachea can hamper the placement of a DLT. Second, a bronchial blocker can be considered after an SLT is placed above the tumor. However, bronchial blockers are easy to be displaced and they require the use of the fiberoptic bronchoscope to verify its position. Furthermore, the repeated use of a fiberoptic bronchoscope can increase the risk of pulmonary infection, tumor rupture, and hemorrhage during tracheal surgery. Therefore, to minimize potential complications of fibreoptic bronchoscopy, the VivaSight SLT was used. It allows a continuous visualization of the airway and immediate correction if a displacement of the bronchial blocker occurs.

Some researchers have reported the advantages of VivaSight SLT. Karczewska et al. showed that VivaSight SLT increased the success rate of intubation at the first attempt, as compared with direct laryngoscopy [9]. Szarpak et al. claimed that VivaSight SLT may be a good first choice for tracheal intubation by a paramedic in a cervical immobilized condition [10]. Some reports showed other applications of VivaSight SLT, such as for percutaneous dilatational tracheostomy [11, 12], for novice physicians intubating without a Macintosh laryngoscope [13], for reducing the number of misplaced tracheal tubes in pre-hospital airway management [14], and for trauma patients trapped in an emergency vehicle during pre-hospital emergency care [15].

VivaSight SLT has also been reported for bronchial blocker placement without bronchoscopy. Its benefits involved a direct continuous monitoring, less time of intubation, and improved patient safety. Moritz et al. used the VivaSight SLT combined with a bronchial blocker in a case of pyothorax with bronchopleural fistula [16]. Granell et al. also demonstrated its use in an awake patient with unknown tracheal stenosis after tracheostomy in thoracic surgery [17].

In conclusion, our case demonstrates a novel approach for tracheal resection and reconstruction. VivaSight™ SLT can provide real-time and continuous monitoring of the position of a bronchial blocker and a tracheal pathological lesion. Moreover, this type of procedure did not require the aid of fiberoptic bronchoscopy, which avoided touching the tumor and interrupting ventilation. Thus, VivaSight™ SLT combined with a bronchial blocker could be a feasible choice for one-lung ventilation in this type of surgery.

Abbreviations

CT:

Computed tomography

DLT:

Double-lumen tube

ID:

Internal diameter

SLT:

Single-lumen tube

VATS:

Video-assisted transthoracic surgery

References

  1. Nakanishi R, Yamashita T, Muranaka K, Shinohara K. Thoracoscopic carinal resection and reconstruction in a patient with mucoepidermoid carcinoma. J Thorac Cardiovasc Surg. 2013;145(4):1134–5.

    Article  Google Scholar 

  2. Jiao W, Zhu D, Cheng Z, Zhao Y. Thoracoscopic tracheal resection and reconstruction for adenoid cystic carcinoma. Ann Thorac Surg. 2015;99(1):e15–7.

    Article  Google Scholar 

  3. Falzon D, Alston RP, Coley E, Montgomery K. Lung isolation for thoracic surgery: from inception to evidence-based. J Cardiothorac Vasc Anesth. 2017;31(2):678–93.

    Article  Google Scholar 

  4. Collins SR, Titus BJ, Campos JH, Blank RS. Lung isolation in the patient with a difficult airway. Anesth Analg. 2018;126(6):1968–78.

    Article  Google Scholar 

  5. Geffin B, Bland J, Grillo HC. Anesthetic management of tracheal resection and reconstruction. Anesth Analg. 1969;48(5):884–90.

    Article  CAS  Google Scholar 

  6. Krecmerova M, Schutzner J, Michalek P, Johnson P, Vymazal T. Laryngeal mask for airway management in open tracheal surgery-a retrospective analysis of 54 cases. J Thorac Dis. 2018;10(5):2567–72.

    Article  Google Scholar 

  7. He J, Wang W, Li J, Yin W, Xu X, Peng G, Chen Y, He P. Video-assisted thoracoscopic surgery tracheal resection and carinal reconstruction for tracheal adenoid cystic carcinoma. J Thorac Dis. 2016;8(1):198–203.

    PubMed  PubMed Central  Google Scholar 

  8. Guo M, Peng G, Wei B, He J. Uniportal video-assisted thoracoscopic surgery in tracheal tumour under spontaneous ventilation anaesthesia. Eur J Cardiothorac Surg. 2017;52(2):392–4.

    Article  Google Scholar 

  9. Karczewska K, Szarpak L, Smereka J, Dabrowski M, Ladny JR, Wieczorek W, Robak O, Frass M, Ahuja S, Ruetzler K. ET-view compared to direct laryngoscopy in patients with immobilized cervical spine by unexperienced physicians: a randomized crossover manikin trial. Anaesthesiol Intensive Ther. 2017;49(4):274–82.

    PubMed  Google Scholar 

  10. Szarpak L, Truszewski Z, Kurowski A, Czyzewski L, Evrin T, Bogdanski L. Tracheal intubation with a VivaSight-SL endotracheal tube by paramedics in a cervical-immobilized manikin. Am J Emerg Med. 2016;34(2):309–10.

    Article  Google Scholar 

  11. Grensemann J, Eichler L, Kahler S, Jarczak D, Simon M, Pinnschmidt HO, Kluge S. Bronchoscopy versus an endotracheal tube mounted camera for the peri-interventional visualization of percutaneous dilatational tracheostomy - a prospective, randomized trial (VivaPDT). Crit Care. 2017;21(1):330.

    Article  Google Scholar 

  12. Grensemann J, Eichler L, Hopf S, Jarczak D, Simon M, Kluge S. Feasibility of an endotracheal tube-mounted camera for percutaneous dilatational tracheostomy. Acta Anaesthesiol Scand. 2017;61(6):660–7.

    Article  CAS  Google Scholar 

  13. Szarpak L, Smereka J, Truszewski Z, Ruetzler K. Can novice physicians intubate with ETView tube without Macintosh laryngoscope? Preliminary data. Am J Emerg Med. 2016;34(11):2242–3.

    Article  Google Scholar 

  14. Koopman EM, Scholtens S, Huitink JM. Visual recognition of anatomical structures in a circulated and in a non-circulated airway. Am J Emerg Med. 2016;34(7):1236–40.

    Article  Google Scholar 

  15. Truszewski Z, Szarpak L, Smereka J, Kurowski A, Evrin T, Czyzewski L. Comparison of the VivaSight single lumen endotracheal tube and the Macintosh laryngoscope for emergency intubation by experienced paramedics in a standardized airway manikin with restricted access: a randomized, crossover trial. Am J Emerg Med. 2016;34(5):929–30.

    Article  Google Scholar 

  16. Moritz A, Schreiner W, Schmidt J. One-lung ventilation after rapid-sequence intubation: a novel approach using an ETView tracheoscopic ventilation tube for placement of an EZ-blocker without bronchoscopy. J Clin Anesth. 2016;29:48–9.

    Article  Google Scholar 

  17. Granell Gil M, Solis Albamonte P, Cordova Hernandez C, Cobo I, Guijarro R, de Andres Ibanez JA. Intubation in two patients with difficult airway management and tracheal stenosis after tracheostomy in thoracic surgery. Rev Esp Anestesiol Reanim. 2018;65(6):347–50.

    Article  CAS  Google Scholar 

Download references

Acknowledgements

None.

Funding

This case report was not funded by any external or internal funding.

Availability of data and materials

The datasets used or presented during this study are available from the corresponding author on request.

Author information

Authors and Affiliations

Authors

Contributions

JQ collected all the patient initial data and drafted the manuscript. MF and CZ completed the anesthesia management. WY raised the initial idea, completed the anesthesia management and made the critical revision of the manuscript. All authors gave their comments on the article and approved the final version.

Corresponding author

Correspondence to Wenlong Yao.

Ethics declarations

Ethics approval and consent to participate

This device we reported has been already approved for clinical use in our country. This patient had signed the informed consent for this anesthesia procedure.

Consent for publication

Written informed consent was obtained from the patient for publication of this article and any accompanying images. A copy of the written consent is available for review by the Editor of this journal.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Qiu, J., Feng, M., Zhang, C. et al. VivaSight™ single-lumen tube guided bronchial blocker placement for one-lung ventilation in a patient with a tracheal tumor under video-assisted transthoracic surgery: a case report. BMC Anesthesiol 19, 2 (2019). https://doi.org/10.1186/s12871-018-0677-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12871-018-0677-3

Keywords