Skip to main content
  • Research article
  • Open access
  • Published:

Effects of time delay and body temperature on measurements of central venous oxygen saturation, venous-arterial blood carbon dioxide partial pressures difference, venous-arterial blood carbon dioxide partial pressures difference/arterial-venous oxygen difference ratio and lactate

Abstract

Background

Central venous oxygen saturation (ScvO2), venous-arterial blood carbon dioxide partial pressures difference (Pv-aCO2), venous-arterial blood carbon dioxide partial pressures difference/arterial-venous oxygen difference ratio (Pv-aCO2/Ca-vO2) and lactate are important parameters employed during shock resuscitation. We designed this study to confirm the effects of time delay and body temperature on measurements of these four parameters.

Methods

Arterial and central venous blood samples were simultaneously drawn by plastic syringes via indwelling intra-arterial and central venous catheters from critically ill patients. Blood gas analyses were performed on both samples and repeated after 10, 20, 30, 40, 50 and 60 min. Patients were divided into a control group and a high temperature group according to whether the body temperature was greater than 38 °C.

Results

A total of 30 critically ill patients were enrolled. There was a trend of increasing values for ScvO2, Pv-aCO2, Pv-aCO2/Ca-vO2 and lactate over time (P < 0.001). The ScvO2 differences were all lower in high temperature group after 10, 20, 30, 40, 50 and 60 min when compared to the corresponding differences in the control group (P < 0.05). The differences in lactate values were slightly higher in the high temperature group, relative to the control group after 20, 30, 40, 50 and 60 min (P < 0.05).

Conclusions

Measurements of ScvO2, Pv-aCO2, lactate and Pv-aCO2/Ca-vO2 were affected by time delay or body temperature. We recommend that arterial and central venous blood gas samples be analyzed quickly within 10 min, especially for patients with body temperature <38 °C.

Trial registration

ChiCTR, ChiCTR1800014484. Registered 16 January 2018.

Peer Review reports

Background

Early recognition and accurate correction of tissue hypoperfusion are important in the treatment of shock. Central venous oxygen saturation (ScvO2), venous and arterial blood carbon dioxide partial pressure difference (Pv-aCO2), the venous–arterial blood carbon dioxide partial pressure difference/arterial-venous oxygen content difference ratio (Pv-aCO2/Ca-vO2) and lactate are important parameters employed during shock resuscitation [1]. ScvO2 is associated with global tissue oxygenation, which can reflect the global balance between arterial O2 delivery and O2 consumption. If the value is low, anaerobic metabolism may arise. It was proved useful for hemodynamic management [2], and was recommended as one of the early resuscitation goals in 2012 sepsis guidelines [3]. Although ScvO2 was deleted in early resuscitation goals in 2016 sepsis guidelines [4], it is still a useful clinical parameter. A ΔScvO2 threshold value of 5.0% discriminated fluid responders from non-responders with a sensitivity of 0.78 and specificity of 0.95 [5]. Moreover, ScvO2 can also predict the success of spontaneous breathing trial [6]. Pv-aCO2 is another alternative possible marker of tissue perfusion. According to the Fick equation, Pv-aCO2 is inversely related to cardiac output [7]. A normal Pv-aCO2<5 mmHg can be used as an adjunctive hemodynamic parameter to exclude tissue hypoperfusion in patients undergoing major surgery [8]. Pv-aCO2 can also help clinicians make decisions of regarding the provision of therapy aimed at increasing cardiac output [7]. The Pv-aCO2/Ca-vO2 ratio was shown to be a good indicator of anerobiosis assessed by hyperlactatemia. Mekontso-Dessap A et al. found that the Pv-aCO2/Ca-vO2 ratio (cut-off value ≥1.6) can detect global anaerobic metabolism in critically ill patients [9]. The Pv-aCO2/Ca-vO2 ratio may provide useful information for assessing the lactate clearance potential and optimizing the lactate clearance rate [10]. Moreover, the Pv-aCO2/Ca-vO2 ratio (cut-off value≥1.6) was an independent predictor of ICU mortality in septic shock patients with high ScvO2 after resuscitation [11]. Increased serum lactate is an early indicator of septic shock and helps accomplish resuscitation goal, and it is recommended utilizing in sepsis guidelines [3, 4]. Given these four parameters above, and their values in shock resuscitation, some researchers have compiled them into a flow sheet to guide resuscitation therapy in septic shock [1].

Before using a clinical parameter in therapeutic decisions, its accuracy is important. Unfortunately, previous studies have found that the values of arterial oxygen partial pressure (PaO2) and arterial carbon dioxide partial pressure (PaCO2) were influenced by time delay and sample storage temperature in blood gas analysis [12, 13]. The effects of time delay and body temperature on the measurements of ScvO2, Pv-aCO2, lactate and Pv-aCO2/Ca-vO2 have not been adequately studied. Thus, we designed this study to confirm the effects of time delay and body temperature on these four specific parameters.

Methods

The study was approved by the Ethics Committee of our hospital and registered at Chinese clinical trial registry (ChiCTR1800014484). It was performed from January 2018 to May 2018 in the intensive care unit of the affiliated hospital of Qingdao university. The patients with indwelling central venous and intra-arterial catheters were enrolled. Therefore, no additional invasive procedures were performed on patients merely to collect blood samples. Patients treated with antipyretic drugs or physical cooling were excluded.

A 2 mL sample of arterial blood was drawn from the indwelling intra-arterial catheter, and simultaneously, 2 mL venous blood sample was collected from the central venous catheter using plastic blood gas syringes (BD Preset™3ml, 22G × 1″, Becton, Dickinson and Company, United Kingdom) by a nurse. The nurse repeatedly drew blood in this manner for a total of 7 times, producing 7 sets of central venous and arterial blood samples simultaneously. Blood gas analysis was performed on one of the sets of the venous and arterial samples via blood gas analyzer (Radiometer ABL90 FLEX, Denmark) as soon as possible after sampling by another nurse. The time needed for transporting samples to the blood gas analyzer was less than 2 min for the first analysis. Then, blood gas analyses were repeated at 10, 20, 30, 40, 50 and 60 min after drawing for remaining 6 sets of samples. During the time delay, the blood samples were stored at 22 °C (room temperature). Pv-aCO2 and the Pv-aCO2/Ca-vO2 ratio were calculated [11].

The patients’ baseline data were also collected, such as age, gender, Acute Physiology and Chronic Health Evaluation (APACHE) II scores and primary diseases. Patients were divided into either the control group or the high temperature group according to whether their body temperature was greater than 38 °C. Body peripheral temperature was measured by mercury thermometer in axilla. Drawing blood gas samples and measuring body temperature were performed simultaneously.

Statistics analysis

The statistical analysis was performed using SPSS 22.0 software (SPSS, Inc., Chicago, IL, USA). The results were expressed as mean ± SD. Statistical analysis of the parameters over time was analyzed by repeated-measures ANOVA (analysis of variance). The statistical significance was set at P <0.05.

Results

A total of 30 critically ill patients were enrolled. The baseline characteristics of them are shown in Tables 1 and 2. There were no significant differences in baseline data between two groups (P > 0.05).

Table 1 Baseline characteristics of patients
Table 2 Baseline characteristics of two groups

There was a trend of increasing values for ScvO2, Pv-aCO2, Pv-aCO2/Ca-vO2 and lactate over time (P < 0.001). ScvO2, Pv-aCO2/Ca-vO2 and lactate values of the samples stored for 10, 20, 30, 40, 50 and 60 min were significantly higher relative to baseline (P < 0.05). There were no significant differences of PaCO2 and PvCO2 value over time (P > 0.05). The values for Pv-aCO2 only increased after 40, 50 and 60 min compared to baseline (P < 0.05), but there were no significant differences after 10, 20 or 30 min (Table 3).

Table 3 Changes in values at different time points

There was a trend of increasing ScvO2 differences, Pv-aCO2 differences, Pv-aCO2/Ca-vO2 differences and lactate differences between baseline and some point along storage time (P < 0.05). The ScvO2 differences between baseline and after 10, 20, 30, 40, 50 and 60 min were all lower in the high temperature group than differences in the control group (P < 0.05). The lactate differences between baseline and 20, 30, 40, 50 and 60 min were all slightly higher in the high temperature group than the differences in the control group (P < 0.05). Pv-aCO2/Ca-vO2 ratio differences between baseline and 10 min were lower in the high temperature group than the ratio differences in the control group (P < 0.05) (Table 4).

Table 4 Comparisons of values between two groups

Discussion

In this study, we found that there was a trend of increasing values for ScvO2, Pv-aCO2, Pv-aCO2/Ca-vO2 and lactate values with increased storage time. The differences in ScvO2, Pv-aCO2/Ca-vO2 and lactate between certain periods of storage time and baseline demonstrated differences between the high temperature group and the control group along certain points of storage time.

According to this study, we often over-estimated SvO2 levels of the central venous blood samples. The guideline of the American Association for Respiratory Care states that a delay in analysis of a venous blood gas of 30 min is acceptable [14]. After a 30 min time delay in analysis, the ScvO2 increased approximately 6% in our study. This indicated that the guideline may lead to unsafe practices. The ScvO2 value was increasing over all storage times in the study, so we recommend blood gas samples be analyzed as soon as possible. It was proven that the PO2 of blood stored in a glass syringe decreases slightly over time, primarily as a result of continuing cellular metabolism [13]. However, plastic syringes have supplanted glass syringes because of their convenience, low cost and breakage resistance. But plastic syringes, unlike glass syringes, are permeable to O2 [15]. Atmospheric O2 has a partial pressure of 159 mmHg, well above venous blood O2. Therefore, O2 will permeate into plastic syringes until there is O2 partial pressure equilibration between the blood sample and the atmosphere. A previous study also indicated that the ScvO2 value increased over storage time [16]. In this study, we found that the rate of ScvO2 change in patients with a temperature ≥ 38 °C was lower than patients with temperature< 38 °C. The baseline ScvO2 values and atmospheric-venous blood O2 partial pressure difference between two groups displayed no difference. Therefore, the increasing O2 consumption may be explained the effects of temperature on ScvO2. We speculated that blood cells have an intrinsically hypermetabolic state in febrile patients and subsequently consumed more O2. Lactate is one of metabolites. The faster rising lactate in the high temperature group of this study may support the idea that blood cells in febrile patients had a high hypermetabolic state. Advanced cell experiments were needed to confirm the hypothesis. In previous studies, temperature correction of blood gas samples is not recommended [14, 17]. But according to our results, the effect of temperature on ScvO2 should not be ignored.

There were no significant differences of PaCO2 and PvCO2 value over time. The Pv-aCO2 increased only approximately 0.2 mmHg after a 30 min time delay in analysis, which may not have very important clinical implications. Furthermore, no effect of temperature on Pv-aCO2 was found. So there were few clinical effects of time delay and temperature on Pv-aCO2 value. In the calculation of Pv-aCO2/Ca-vO2 [11], O2 partial pressure is an important parameter. Because of effects of the time delay on blood O2 partial pressure [12, 13], Pv-aCO2/Ca-vO2 may also be affected by time delay. In actuality, our results proved that this is the case. After a 30 min time delay, the ratio increased 1 by almost. Further, Pv-aCO2/Ca-vO2 difference was lower in patients in the high temperature group. At 10 min, the value demonstrated a significant difference. Lactate values were also affected by time delay and temperature, but the influence was not very strong. After a 30 min time delay, the lactate increased only approximately 0.4 mmol/L.

Conclusions

There were some influences of time delay or body temperature on ScvO2, Pv-aCO2, lactate and Pv-aCO2/Ca-vO2 values. We recommend that arterial and central venous blood gas samples be analyzed quickly within 10 min, especially for patients with body temperature <38 °C.

Abbreviations

APACHE:

Acute Physiology and Chronic Health Evaluation

Lac:

Lactate

PaCO2 :

Arterial carbon dioxide partial pressure

PaO2 :

Arterial oxygen partial pressure

Pv-aCO2 :

Venous and arterial blood carbon dioxide partial pressures difference

Pv-aCO2/Ca-vO2 :

Venous and arterial blood carbon dioxide partial pressures difference/arterial-venous oxygen difference ratio

ScvO2 :

Central venous oxygen saturation

References

  1. Mallat J, M L, Tronchon L, Vallet B, Thevenin D. Use of venous-to-arterial carbon dioxide tension difference to guide resuscitation therapy in septic shock. World J Crit Care Med. 2016;5(1):47–56. https://doi.org/10.5492/wjccm.v5.i1.47.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Mikor A, Trásy D, Németh MF, Osztroluczki A, Kocsi S, Kovács I, et al. Continuous central venous oxygen saturation assisted intraoperative hemodynamic management during major abdominal surgery: a randomized, controlled trial. BMC Anesthesiol. 2015;15:82. https://doi.org/10.1186/s12871-015-0064-2.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  3. Dellinger RP, Levy MM, Rhodes A, Annane D, Gerlach H, Opal SM, et al. Surviving Sepsis campaign: international guidelines for management of severe sepsis and septic shock, 2012. Intensive Care Med. 2013;39(2):165–228. https://doi.org/10.1007/s00134-012-2769-8.

    Article  CAS  PubMed  Google Scholar 

  4. Rhodes A, Evans LE, Alhazzani W, Levy MM, Antonelli M, Ferrer R, et al. Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock: 2016. Crit Care Med. 2017;45(3):486–552.

    Article  Google Scholar 

  5. Xu B, Yang X, Wang C, Jiang W, Weng L, Hu X, Peng J, Du B. Changes of central venous oxygen saturation define fluid responsiveness in patients with septic shock: a prospective observational study. J Crit Care. 2017;38:13–9. https://doi.org/10.1016/j.jcrc.2016.09.030.

    Article  PubMed  Google Scholar 

  6. Georgakas I, Boutou AK, Pitsiou G, Kioumis I, Bitzani M, Matei K, Argyropoulou P, Stanopoulos I. Central venous oxygen saturation as a predictor of a successful spontaneous breathing trial from mechanical ventilation: a prospective, nested case-control study. Open Respir Med J. 2018;12:11–20. https://doi.org/10.2174/1874306401812010011.

    Article  PubMed  PubMed Central  Google Scholar 

  7. Lamia B, Monnet X, Teboul JL. Meaning of arterio-venous PCO2 difference in circulatory shock. Minerva Anestesiol. 2006;72(6):597–604.

    CAS  PubMed  Google Scholar 

  8. Silbert BI, Litton E, Ho KM. Central venous-to-arterial carbon dioxide gradient as a marker of occult tissue hypoperfusion after major surgery. Anaesth Intensive Care. 2015;43(5):628–34.

    CAS  PubMed  Google Scholar 

  9. Mekontso-Dessap A, Castelain V, Anguel N, Bahloul M, Schauvliege F, Richard C, Teboul JL. Combination of venoarterial PCO2 difference with arteriovenous O2 content difference to detect anaerobic metabolism in patients. Intensive Care Med. 2002;28(3):272–7.

    Article  Google Scholar 

  10. He HW, Liu DW, Long Y, Wang XT. High central venous-to-arterial CO2 difference/arterial-central venous O2 difference ratio is associated with poor lactate clearance in septic patients after resuscitation. J Crit Care. 2016;31(1):76–81. https://doi.org/10.1016/j.jcrc.2015.10.017.

    Article  PubMed  Google Scholar 

  11. He H, Long Y, Liu D, Wang X, Tang B. The Prognostic Value of Central Venous-to-Arterial CO2 Difference/Arterial-Central Venous O2 Difference Ratio in Septic Shock Patients with Central Venous O2 Saturation ≥80. Shock. 2017;48(5):551–7. https://doi.org/10.1097/SHK.0000000000000893.

    Article  PubMed  Google Scholar 

  12. Mohammadhoseini E, Safavi E, Seifi S, Seifirad S, Firoozbakhsh S, Peiman S. Effect of sample storage temperature and time delay on blood gases, bicarbonate and pH in human arterial blood samples. Iran Red Crescent Med J. 2015;17(3):e13577. https://doi.org/10.5812/ircmj.13577.

    Article  PubMed  PubMed Central  Google Scholar 

  13. Srisan P, Udomsri T, Jetanachai P, Lochindarat S, Kanjanapattanakul W. Effects of temperature and time delay on arterial blood gas and electrolyte measurements. J Med Assoc Thail. 2011;94(Suppl 3):S9–14.

    Google Scholar 

  14. Davis MD, Walsh BK, Sittig SE, Restrepo RD. AARC clinical practice guideline: blood gas analysis and hemoximetry: 2013. Respir Care. 2013;58(10):1694–703. https://doi.org/10.4187/respcare.02786.

    Article  PubMed  Google Scholar 

  15. Ruppel GL. Of time and temperature, plastic and glass: specimen handling in the blood-gas laboratory. Respir Care. 2006;51(7):717–8.

    PubMed  Google Scholar 

  16. Ghanpur R, Santamaria J, Dixon B. Plastic blood gas syringes and measurement error in central venous oxygen saturations. Shock. 2016;46(3):287–9. https://doi.org/10.1097/SHK.0000000000000622.

    Article  CAS  PubMed  Google Scholar 

  17. Shapiro BA. Temperature correction of blood gas values. Respir Care Clin N Am. 1995;1(1):69–76.

    CAS  PubMed  Google Scholar 

Download references

Acknowledgements

Not applicable

Funding

Not applicable

Availability of data and materials

The datasets during the current study available from the corresponding author on reasonable request.

Author information

Authors and Affiliations

Authors

Contributions

BY designed the study and modified the manuscript. XW participated in the design of the study, performed the statistical analysis and drafted the manuscript. XW, LW, YJ and PL performed the study and collected data. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Bo Yao.

Ethics declarations

Ethics approval and consent to participate

This study was approved by the affiliated hospital of Qingdao university ethics committee and registered at Chinese clinical trial registry (ChiCTR1800014484). The written informed consent was obtained from the next of kin of the patients before their enrollment.

Consent for publication

Not applicable

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Wan, Xy., Wei, Ll., Jiang, Y. et al. Effects of time delay and body temperature on measurements of central venous oxygen saturation, venous-arterial blood carbon dioxide partial pressures difference, venous-arterial blood carbon dioxide partial pressures difference/arterial-venous oxygen difference ratio and lactate. BMC Anesthesiol 18, 187 (2018). https://doi.org/10.1186/s12871-018-0655-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12871-018-0655-9

Keywords