Situation awareness errors in anesthesia and critical care in 200 cases of a critical incident reporting system

Abstract

Background

A loss of adequate Situation Awareness (SA) may play a major role in the genesis of critical incidents in anesthesia and critical care. This observational study aimed to determine the frequency of SA errors in cases of a critical incident reporting system (CIRS).

Methods

Two experts independently reviewed 200 cases from the German Anesthesia CIRS. For inclusion, reports had to be related to anesthesia or critical care for an individual patient and take place in an in-hospital setting. Based on the SA framework, the frequency of SA errors was determined. Representative cases were analyzed qualitatively to illustrate the role of SA for decision-making.

Results

SA errors were identified in 81.5 %. Predominantly, errors occurred on the levels of perception (38.0 %) and comprehension (31.5 %). Errors on the level of projection played a minor role (12.0 %). The qualitative analysis of selected cases illustrates the crucial role of SA for decision-making and performance.

Conclusions

SA errors are very frequent in critical incidents reported in a CIRS. The SA taxonomy was suitable to provide mechanistic insights into the central role of SA for decision-making and thus, patient safety.

Peer Review reports

Background

Accurate Situation Awareness (SA) is the indispensable precursor for correct decision-making and action [13]. Therefore, it is likely that errors frequently evolve from incorrect SA. Endsley defined SA as “the perception of elements of the environment within a volume of time and space, the comprehension of their meaning and the projection of their status in the near future” [4]. In anesthesia and critical care, the first and lowest level of SA is the perception of information that is provided by the patient (e.g., through verbal communication or appearance), monitors, patient charts, communication within the team, anesthesia machine, respirators, and the surgical field (perception, SA level I) [1]. On the second level, information is processed in order to comprehend the patient’s state (comprehension, SA level II). On the third and highest level, health care providers estimate how the patient will develop in the next minutes and hours (projection, SA level III). Generating SA on this level is challenging but important since it allows for proactive management of human and material resources during crisis. To also cover team processes, the framework has been extended defining team SA as “the degree to which every team member possesses the SA required for his or her responsibilities” [5].

Endsley suggested a taxonomy that differentiates between different types of errors on each of the three SA levels (Table 1) [6]. In SA level I (perception) errors, relevant information was not perceived (e.g., damaged or missing monitoring equipment as well as communication problems within the health care team can limit the information necessary for adequate SA of an individual). Errors on SA level II (comprehension) occur if a complete set of information is not processed correctly resulting in imperfect comprehension of the situation. Errors on the SA level III (projection) take place if a situation is well understood but the future development is estimated falsely. This error taxonomy has previously been used successfully to systematically analyze incidents in aviation [6, 7].

Table 1 Endsley’s taxonomy of Situation Awareness errors

Similar to the Aviation Safety Reporting System, voluntary Critical Incident Reporting Systems (CIRS) have been introduced into anesthesia in several European countries in the last fifteen years [8]. CIRS offer individuals an anonymous platform to report errors and near misses. In a review article, Mahajan emphasized that a systematic analysis of each report is a prerequisite for changes in daily practice [9]. For the purpose of a systematic analysis of errors and error mitigation, error classification [10, 11] and reporting [12, 13] systems have been developed and applied. However, none of them specifically addressed SA errors as a potentially important underpinning mechanism.

Therefore, we determined the frequency of SA errors on the particular SA levels in 200 CIRS cases in anesthesia and critical care. Additionally, a sample of CIRS cases was analyzed qualitatively according to the SA error taxonomy in order to illustrate how SA errors can be associated with wrong decisions, potentially harming the patient.

Methods

Study design

After approval of the Research Ethics Board (Technische Universität München, 5770/13, 26th of April, 2013), 200 cases from the German Anesthesia CIRS were analyzed by two independent experts (VK and CS). According to the nature of CIRS, informed consent could not be obtained as the involved individuals remain anonymous. To minimize selection bias, the cases (dating from April to November 2013) were selected in strict consecutive order. For inclusion, a case had to deal with an individual patient and had to be in-hospital and related to anesthesia or critical care. Some reports described general, e.g., structural problems or commented on compromised safety of health care staff. Although the problems described in those cases may significantly impact SA on the level of both individuals and teams, they were excluded as the cases were beyond one individual’s SA and actions. If a case met the inclusion criteria, the experts determined the SA level on which the error occurred as described below.

Data acquisition

The CIRS used for this study is operated by the German Society of Anesthesiology and Intensive Care Medicine (DGAI), the Agency for Quality in Medicine (ÄZQ) and the Alliance of German Anesthesiologists (BDA). Any health care provider can access the platform without restrictions for both reporting and looking through published reports. The reporters are invited to describe critical incidents and near misses. Prior to publication, trained personnel carefully checks every report for anonymity and content in order to avoid blaming language as well as any possibility to trace back to the persons involved in the case. In this step, also any information and judgment that appears unrelated or unimportant is deleted.

Users report the content of the case in a narrative style of varying length. A part from that, the users can provide data about location (anesthesia, post-anesthesia care unit, intensive care unit, in-hospital transports, code blue team, acute pain management, premedication, other), time point (working day vs. weekend), estimated frequency of this kind of incident (almost daily, weekly, monthly, several times a year, seldom, only this time), professional status of the reporting health care provider (physician, nurse, paramedic, other), his or her work experience (more or less than 5 years), routine vs. emergency case, ASA-classification and whether any medical device was involved. This was recorded to investigate whether the presence and level of SA errors depended on the above-mentioned categorical variables.

Analysis of CIRS cases for identification of SA errors

In the first step, the critical action of an individual in a case (e.g., the administration of wrong drug, or the absence of an action that would have resolved the problem) was identified. Then, based on the framework of the anesthetist’s SA and Endsley’s definition of SA errors [1, 6], the experts analyzed whether inadequate SA was associated with the decision leading to that action (or non-action, respectively). This required a yes/no response by the experts. If a SA error occurred, also the level (perception vs. comprehension vs. projection) on which the error occurred was determined. If errors occurred on various levels and were related to each other, the experts assigned the error to the most basic level, e.g., pulse oximetry was not used and a health care provider did not comprehend that the patient was desaturating. In this scenario, the causing error was on the level of perception and therefore, only this error was coded. If various SA errors occurred independently from each other, the experts only coded the error, which was directly associated with the critical action. The experts analyzed each case independently. If the experts disagreed with respect to the occurrence of a SA error or the level on which the error occurred, the respective case was turned back to the experts for independent re-evaluation. If there remained difficulties to assign the cases to a SA level, consensus was obtained after mutual discussion between three of the authors (CS, VK, KW).

With the aim of illustrating each type of error according to the taxonomy described above, we identified cases that were detailed enough for an analysis of types of errors of the specific SA levels. Each case was translated into English, followed by a brief qualitative analysis in terms of the SA framework and an assignment of the underlying types of error. Additionally, three cases are described where SA was lost and re-gained or where active efforts to gain SA prevented a patient from damage in a rapidly changing situation.

Statistical analysis

The intended number of 200 included cases permitted to estimate the frequency of a certain case with an accuracy of at least 7 %, which is the confidence interval for the estimated relative frequency. Furthermore, even rare events with a frequency of 1.5 % will be detected at a likelihood of 95 %. Frequencies of SA errors, the respective SA levels and the results of error classification are given as percentage. For an exploratory analysis of correlations between SA errors and categorical data, cross-tables were used with either Chi-square test or Fisher’s exact test when tables contained values of 5 or less. Reliability was calculated using Cohen’s kappa based on the initial assessment of the experts. P-values < 0.05 were considered statistically significant. All statistical analysis was done with IBM SPSS Statistics Version 22.0 (IBM Corp., Armonk, New York, USA).

Results

Frequency of SA errors

248 cases had to be tested for inclusion criteria in order to extract 200 cases that were reviewed by the experts (Fig. 1). 77.5 % of cases were routine cases whereas 21 % were considered to be emergency situations (1.5 % non defined). 24.5 % of cases were reported as singular events, 38.0 % as seldom, 19 % occurred several times a year. The remaining cases (18.5 %) were reported to occur at least monthly. 82.5 % of cases were reported by physicians with 27.9 % of them having less than 5 years of experience. 14.0 % of cases were reported by nurses (with only 10.7 % of them having less than 5 years of experience). Median of ASA score was 2.

Fig. 1
figure 1

Flow chart. Of 248 cases reviewed, 80.6 % met inclusion criteria. The majority was attributable to anaesthesia (51.5 %), whereas cases on ICU (18.0 %) and PACU (6.0 %) were less frequent. The remaining 49 cases (24.5 %) occurred in locations such as during transports, in code blue teams, during premedication visit or acute pain management. (CIRS = Critical incident reporting system, ICU = intensive care unit, PACU = post-anaesthesia care unit)

SA errors were identified in 163 cases (81.5 %). The large majority was attributed to the levels of perception and comprehension (Fig. 2). Both experts agreed in 90 % of cases whether an SA error was present or not (Cohen’s kappa 0.69). With respect to the level on which the error occurred, agreement was present in 66.9 % (Cohen’s kappa 0.48) of cases.

Fig. 2
figure 2

Distribution of SA errors on the levels perception, comprehension and projection

Cross tables revealed that the frequency of SA errors and the level on which they occurred were independent from the location (anesthesia, ICU, PACU, other/not specified) and from other categorical data (time point, estimated frequency, professional status, work experience, routine vs. emergency case, ASA-classification and whether a medical device was involved into the incident [data not shown]).

Qualitative analysis of SA errors

In the following, cases with SA errors are described (see Table 2 for details). Case 1 refers to information that was either missing due to insufficient communication or that was simply forgotten. Cases 2–4 are examples of barriers that physically preclude from information to become (acoustic and visual) sensory input (e.g., “After putting the drapes, the access to both peripheral iv lines was hampered”). In case 3, specifically, “small fonts” on a display prevented from a more timely recognition of the fact that a propofol syringe pump ran with remifentanil and vice versa. In case 5, relevant information was missed due to the decision not to use a patient monitor. Case 6 describes the misperception of drug labels resulting in the decision to use hydroxyethyl starch to keep open an arterial line. The reporting individual identified a look-alike problem of drugs (“both look similar”) which is a problem addressed extensively elsewhere [14]. In these cases (1–6), the involved individuals did not perceive relevant information and consequently, they did not comprehend important aspects of the situation and, as a result, wrong or no decisions were made.

Table 2 Fifteen examples of SA errors

In cases 7–12 the information was complete but processed incorrectly. In case 7, a health care provider was not familiar with the operating mode of a pump, nevertheless he operated the pump and unintentionally administered a bolus. A similar problem occurred in the cases 8 and 9 where drugs were administered in the wrong way. In SA terms, incorrect mental models were applied. Cases 10 and 11 illustrate incomplete comprehension of a situation due to the over-reliance on default values. In case 10 an anesthesiologist incorrectly assumed that a syringe was ready to use. In case 11 the drugs were prepared as usual in spite of a drug order that differed considerably from routine. In case 12, presumably, the anesthesiologist was aware that a lobectomy was to be performed using stapler technique. Nevertheless, he had introduced the suction catheter into the tracheal lumen of the tube. These two points were not brought together, as this set of information did not fit into preformed long-term memory content indicating a lack of a mental model.

Cases 13 and 14 provide examples of how anesthesiologists unexpectedly are confronted with a problem or a deterioration of the patient, indicating incomplete awareness on the level of projection. In case 15, a team member (a student) did not inform the rest of the team about his situation awareness (SA level I and II) with respect to a patient in the emergency department. As a result, not every team member possessed the SA needed for her/his responsibilities (Team SA).

In contrast, the cases 16–18 (Table 3) illustrate how the search for additional information and continuous re-evaluation of the situation is crucial to maintain SA. In case 16, an additional routine check of basic data prevents a transfusion incident whereas in case 17, a situation (esophageal intubation) is not comprehended until additional information (bronchoscopy) is sought and processed. Case 18 is an example of a situation in course of a transport of a patient for computed tomography where the basic information changes very quickly and in an unexpected manner. The persons involved were able to dynamically adapt their SA and this enabled them to make the right decisions in face of at least two life-threatening problems.

Table 3 Three Examples of re-established SA

Discussion

Quantitative reports about the frequency of SA errors in health care have been absent so far. This study provides evidence that SA errors are frequent in those critical incidents cases that were reported voluntarily in a CIRS. This is in accordance with findings from aviation where the frequency of SA problems in operational errors ranged between 59 % and 88 % [15]. In this exploratory approach, the frequency of SA errors and the distribution between the SA levels did not differ significantly between anesthesia, ICU, PACU and others. Furthermore, it was independent from the estimated frequency, professional status and experience of the reporting individual. Only in a minority of cases with critical incident (18.5 %), no critical action was identified or tracing down from a critical action to an associated SA error was not possible. Several other studies in health care qualitatively examined the role of SA in different settings such as during diagnostic errors in primary care [16], in nurses during medication administration [17] and during object transfer in the operating theatre [18], and the interdisciplinary management of patient risk in inpatient settings [19]. However, no study provided quantitative data about the frequency of SA errors in any setting so far.

In contrast to an analysis of 143 incidents reported in the voluntary Aviation Safety Reporting System (76.3 % SA level I errors, 20.3 % SA level II errors and 3.4 % SA level III errors) [7], we found less errors on the level of perception and more errors on the levels of comprehension and projection. As errors on the SA levels II and III necessarily involve long-term memory content for the processing of basic data [1], this may be due to a lack of training and experience. This is not surprising because staffing in health care is, in contrast to commercial aviation, less standardized with respect to quality and quantity. Another domain-specific explanation is that both, pilots and air traffic controllers work in highly standardized settings and they always utilize the same set of information (e.g., pilots always have an altimeter available). An anesthetist, in contrast, has to actively seek for information (e.g., through observing the surgical field or through communication) and must decide whether an additional source of information (e.g., arterial line) is essential for successful management of the case and whether invasive measures are justified.

The cases for the qualitative analysis were selected purposefully with the aim of providing examples for each of the type of error in Endsley’s taxonomy. We intended to demonstrate that errors on the more basic levels obligatorily cause errors on the more advanced levels and finally lead to wrong or missing decisions that in turn compromise patient safety or even cause patient harm. This relationship was reflected by cases where wrong decisions base on a lack of SA and cases in which SA abilities in dynamic situations resulted in adequate management of a problem. In this sample, the taxonomy was suitable for providing mechanistic insights in the analysis of particular cases. In one qualitative study on diagnostic errors in primary care, the SA framework was also found to be useful for a descriptive evaluation [16].

An important pre-condition, however, for breaking down the causality from critical action to decision-making and further to SA with types of errors on the respective SA levels, was that the reports had to be detailed enough. That was seldom the case and is also reflected by the fact that the a priori accordance of the raters decreased with increasing depth of analysis. For example, on the level of individuals, it can be difficult to decide whether an error occurred due to the missing arterial line (information not available, perception) or whether the error occurred due to the decision not to place an arterial line (incomplete, an incorrect or an absent mental model, comprehension or projection). On the level of teams, the reports were not detailed enough to detect possibly missing team interactions such as SA cross-checking. Therefore, this approach does not necessarily cover ineffective teamwork where SA is considered to be an important determinant for performance [20]. For that purpose, other databases are required. Finally, our approach only identified one individual SA error per case, specifically the error which led to a wrong decision and consequently to the critical action. As even one single SA error can be multifactorial, this is not in contrast to Reason who used the Swiss cheese model to illustrate that often more than one defense barrier has to fail before an error occurs [10]. In this context it is important to remark that in our study the SA construct was used to analyze SA errors that occur in individuals rather than to analyze SA errors that are caused by individuals. In hindsight it is easy to determine which SA the individual should have possessed as “people holding a false belief do not know it is false” [21]. To prevent the individuals from being blamed, however, it is imperative to assess the information available in the respective situation and the conditions under which the individual worked. Furthermore, the individual’s long-term memory content and the extent to which it is available for data processing, e.g., under conditions of high workload, has to be considered. Long-term memory content is integral for building SA on the levels II and III and cannot be influenced by the individuals in course of a critical incident [1]. Obviously, this concept is helpful for a better understanding of decision-making but, in the far majority of cases, it does not allow for drawing conclusions with regard to the individual’s responsibility to gain and maintain accurate SA [21, 22].

There is a large body of literature about human errors. Reason promoted a paradigm change when he suggested shifting the focus from the individual to the system, in order to continuously improve the conditions under which humans work and thus, to reduce errors and enhance reliability in health care [10]. Another important step was to systematically analyze the frequency and quality of critical incidents, the first among them the Closed Claims Project of the American Society of Anesthesiologists [23] and the Australian Critical Incident Monitoring Study [12]. Both have led to a number of changes in daily practice [24]. Two recent interventions, a new drug administration system [25] and the World Health Organization’s Surgical Safety Checklist [26], resulted in reduced mortality and adverse events. In our view both interventions intend to enhance SA: The drug administration system provides additional auditory input on the level of perception, includes cognitive aids (e.g., it remembers to administer antibiotics within 15 min after skin incision) and intends to reduce workload by an electronic health record, which permits observing the patient more intensively [25]. The Surgical Safety Checklist promotes Team SA by forcing communication through a standardized form [1, 26].

Some important limitations are inherent to any analysis based on CIRS. Evidently, the reports are of limited length, reported chronologically, and explanatory elements often limit to the medical and technical context. Accordingly, reporting individuals rarely consider human elements such as non-technical skills. Recently, Haller et al. reported clinical factors that were associated with non-use of the system such as regional anesthesia, emergency procedures and severe complications with a high risk of litigation [27]. Furthermore, there are hindering factors such as the individual’s role in an incident, and a lack of safety culture on the individual as well as on the institutional level. Not all hospitals and departments agree to publish their cases. Additionally, with the aim of ensuring the reporter’s and patient’s anonymity, in some cases the CIRS personnel may be forced to delete also important information including whether or the extent to which a patient may have been harmed. Taken all together, in case-to-case decisions, only a minority of the real critical incidents is published in CIRS and therefore, the results are not a valid picture of the real quality and quantity of critical incidents. Nevertheless, in face of the frequency of SA errors in this subsample and the possibility to mechanistically describe their consequences, the authors suggest that the SA framework is a promising approach to enhance our knowledge about the development of human error in health care. However, more representative databases are required. For the SA framework, it still has to be shown that the approach of analyzing incidents is suitable to 1) systematically and completely detect causal relationships between SA, decision-making and performance, 2) to identify factors that contribute to these SA errors, and 3) to derive promising interventions that successfully address frequent sources of SA errors.

Another technique designed to develop a thorough understanding of domain-specific SA requirements and cognitive decision-making processes is the Goal-Directed Task Analysis [28]. It is a form of cognitive task analysis that focuses on individual’s goals, decisions, and information requirements that support those goals and decisions. Based thereupon, future promising steps include the development of more user-centered monitoring systems that, for example, integrate basic data in order to provide information that directly enhances individuals’ SA on the more advanced levels [29], e.g., by suggesting a diagnosis. In some locations, structural alterations that not only address the availability of but also the use of monitoring systems may be a relatively easy first step. Last but not least, new training approaches should be directed to foster the individual skills needed for developing SA adequately and quickly.

Conclusion

In conclusion, SA errors are very frequent in critical incidents reported in the German CIRS for anesthesia and critical care. The SA framework is suitable to provide mechanistic insights into the development of critical incidents. However, prior to identifying promising interventions for the reduction of SA errors, further robust analysis tools and representative databases for the health care system are required.

Abbreviations

ÄZQ:

Agency for Quality in Medicine

BDA:

Berufsverband Deutscher Anästhesisten (Alliance of German Anesthesiologists)

CIRS:

Critical Incident Reporting System

DGAI:

Deutsche Gesellschaft für Anästhesiologie und Intensivmedizin (German Society, of Anesthesiology and Intensive Care Medicine)

ICU:

Intensive Care Unit

PACU:

Post anesthesia care unit

SA:

Situation Awareness

References

  1. Schulz CM, Endsley MR, Kochs EF, Gelb AW, Wagner KJ. Situation awareness in anesthesia: concept and research. Anesthesiology. 2013;118(3):729–42.

    Article  PubMed  Google Scholar 

  2. Endsley MR. The role of situation awareness in naturalistic decision making. In: Zsambok CE, Klein G, editors. Naturalistic decision making. Mahwah: LEA; 1997. p. 269–83.

    Google Scholar 

  3. Hänsel M, Winkelmann AM, Hardt F, Gijselaers W, Hacker W, Stiehl M, et al. Impact of simulator training and crew resource management training on final-year medical students’ performance in sepsis resuscitation: a randomised trial. Minerva Anesthesiol. 2012;78(8):901–9.

    Google Scholar 

  4. Endsley MR. Towards a Theory of Situation Awareness in Dynamic Systems. Hum Factors. 1995;37:32–64.

    Article  Google Scholar 

  5. Endsley MR, Jones WM. A model of inter and intra-team situation awareness: implications for design, training and measurement. In: McNeese M, Salsa M, Endsley MR, editors. New trends in cooperative activities: understanding system dynamics in complex environments. Santa Monica: Human Factors and Ergonomics Society; 2001. p. 1–24.

  6. Endsley MR. A taxonomy of Situation Awareness Errors. In: Fuller R, Johnston N, McDonald N, editors. Human Factors in Aviation Operations. Aldershot: Ashgate Publishing; 1995. p. 287–92.

    Google Scholar 

  7. Jones DG, Endsley MR. Sources of situation awareness errors in aviation. Aviat Space Environ Med. 1996;67(6):507–12.

    PubMed  CAS  Google Scholar 

  8. Reed S, Arnal D, Frank O, Gomez-Arnau JI, Hansen J, Lester O, et al. National critical incident reporting systems relevant to anaesthesia: a European survey. Br J Anaesth. 2014;112(3):546–55.

    Article  PubMed  CAS  Google Scholar 

  9. Mahajan RP. Critical incident reporting and learning. Br J Anaesth. 2010;105(1):69–75.

    Article  PubMed  CAS  Google Scholar 

  10. Reason J. Human error: models and management. BMJ. 2000;320(7237):768–70.

    Article  PubMed  CAS  PubMed Central  Google Scholar 

  11. Rasmussen J. Human errors. A taxonomy for describing human malfunction in industrial installations. J Occup Accidents. 1982;4(2–4):311–33.

    Article  Google Scholar 

  12. Willamson JA, Webb RK, Sellen AR, Runciman WB, van der Walt JH. The Australian Incident Monitoring Study. Human Failure: an analysis of 2000 reports. Anaesth Intensive Care. 1993;21(5):678–83.

    Google Scholar 

  13. Beckmann U, West LF, Groombridge GJ, Baldwin I, Hart GK, Clayton DG, et al. The Australian Incident Monitoring Study in Intensive Care: AIMS-ICU. The development and evaluation of an incident reporting system in intensive care. Anaesth Intensive Care. 1996;24(3):314–9.

    PubMed  CAS  Google Scholar 

  14. Ciociano N, Bagnasco L. Look alike/sound alike drugs: a literature review on causes and solutions. Int J Clin Pharm. 2014;36(2):233–42.

    Article  PubMed  CAS  Google Scholar 

  15. Endsley MR. Situation Awareness and Human Error: Designing to Support Human Performance. Albuquerque: Proceedings of the High Consequence Systems Surety Conference; 1999.

    Google Scholar 

  16. Singh H, Giardina TD, Petersen LA, Smith MW, Paul LW, Dismukes K, et al. Exploring situational awareness in diagnostic errors in primary care. BMJ Qual Saf. 2012;21(1):30–8.

    Article  PubMed  PubMed Central  Google Scholar 

  17. Sitterding MC, Ebright P, Broome M, Patterson ES, Wuchner S. Situation Awareness and Interruption Handling During Medication Administration. West J Nurs Res. 2014;36(7):891–916.

    Article  PubMed  Google Scholar 

  18. Korkiakangas T, Weldon SM, Bezemer J, Kneebone R. Nurse-surgeon object transfer: video analysis of communication and situation awareness in the operating theatre. Int J Nurs Stud. 2014;51(9):1195–206.

    Article  PubMed  Google Scholar 

  19. Brady PW, Goldenhar LM. A qualitative study examining the influences on situation awareness and the identification, mitigation and escalation of recognised patient risk. BMJ Qual Saf. 2014;23(2):153–61.

    Article  PubMed  Google Scholar 

  20. Endsley MR, Jones WM. A model of inter- and intrateam situation awareness: Implications for design, training and measurement. In: McNeese M, Salas E, Endsley M, editors. New trends in cooperative activities: Understanding system dynamics in complex environments. Santa Monica: Human Factors and Ergonomics Society; 2001. p. 46–67.

    Google Scholar 

  21. Breakey H, van Winsen RD, Dekker SW. “Loss of situation awareness” by medical staff: reflecting on the moral and legal status of a psychological concept. J Law Med. 2015;22(3):632–7.

    PubMed  Google Scholar 

  22. Dekker SW. The danger of losing situation awareness. Cogn Tech Work. 2015;17:159–61.

    Article  Google Scholar 

  23. Caplan R. The Closed Claims Project: Looking Back, Looking Forward. ASA Newsletter. 1999;63(6):7–9.

    Google Scholar 

  24. Petty WC, Kremer M, Biddle C. A synthesis of the Australian Patient Safety Foundation Anesthesia Incident Monitoring Study, the American Society of Anesthesiologists Closed Claims Project, and the American Association of Nurse Anesthetists Closed Claims Study. AANA J. 2002;70(3):193–202.

    PubMed  Google Scholar 

  25. Merry AF, Webster CS, Hannam J, Mitchell SJ, Henderson R, Reid P, et al. Multimodal system designed to reduce errors in recording and administration of drugs in anaesthesia: prospective randomised clinical evaluation. Bmj. 2011;343:d5543.

    Article  PubMed  PubMed Central  Google Scholar 

  26. Haynes AB, Weiser TG, Berry WR, Lipsitz SR, Breizat AH, Dellinger EP, et al. A surgical checklist to reduce morbidity and mortalitiy in a global population. N Engl J Med. 2009;360(5):491–9.

    Article  PubMed  CAS  Google Scholar 

  27. Haller G, Courvoisier DS, Anderson H, Myles PS. Clinical factors associated with the non-utilization of an anaesthesia incident reporting system. Br J Anaesth. 2011;107(2):171–9.

    Article  PubMed  CAS  Google Scholar 

  28. Endsley MR, Jones DG. Designing for situation awareness: An Approach to User-Centered Design. 2nd ed. London: CRC Press; 2011. p. 147–68.

    Book  Google Scholar 

  29. Kiefer H, Hoeft A. Display of information in the operating room. Curr Opin Anaesthesiol. 2010;23(6):772–7.

    Article  PubMed  Google Scholar 

Download references

Acknowledgments

The work was supported by the Department of Anesthesiology, Klinikum rechts der Isar, Technische Universität München.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Christian M. Schulz.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

CS designed the study and acquired the data. VK acquired the data, AH provided important intellectual content for the design of the study, MK analyzed the data, EK and KW critically revised the paper for important intellectual content. All authors finally approved the version to be published.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Schulz, C.M., Krautheim, V., Hackemann, A. et al. Situation awareness errors in anesthesia and critical care in 200 cases of a critical incident reporting system. BMC Anesthesiol 16, 4 (2015). https://doi.org/10.1186/s12871-016-0172-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12871-016-0172-7

Keywords