Skip to main content

Table 1 Comparison of capnograph-derived PCO2s in different measurements between ventilated patients with hook method, T/E method and E/C technique

From: Evaluation the quality of bag-mask ventilation by E/C, T/E and hook technique (a new proposed technique)

Measurement time

Technique used for ventilation

p-value

Group effect

p-value

Time effect

p-value

T/E method

Median (IQR*)

E/C method

Median (IQR)

Hook method

Median (IQR)

The 2nd second

20 (20–23)

21(22 − 20)

21 (20–22)

0.199

0.006**

< 0.001**

The third second

24 (22–25)

23(24 − 21)

23 (23–24)

0.114

The fourth second

24 (22–26)

25(26 − 23)

25 (24–26)

0.071

The fifth second

26(24–27)

26(28 − 24)

26 (25–27)

0.008

The sixth second

25 (23–27)

28(29 − 25)

27 (26–28)

< 0.001

The seventh second

26(24–29)

29(30 − 27)

28 (27–29)

< 0.001

The eight second

28(26–30)

30(31 − 29)

29 (28–30)

< 0.001

The ninth second

29 (25.27-31)

31(33 − 29)

30 (28–31)

0.134

The tenth second

31(29–34)

32(34 − 30)

31 (29–32)

0.377

  1. *IQR = InterQuartileRange
  2. ** significant