Skip to main content

Table 2 Ultrasound measurements and the calculated parameters

From: Exploring the predictive value of combined ultrasound parameters for spinal anesthesia-induced hypotension in cesarean section: a prospective observational study

 

Normotension group

(n = 31)

Hypotension group

(n = 57)

P value

Parameters in supine position

 LVOTa diameter (cm)

1.8 ± 0.1

1.8 ± 0.1

0.575

 LVEDAsb (cm2)

11.9 ± 2.7

10.4 ± 1.8

0.002※

 VTIsc (cm)

24.8 ± 3.6

21.7 ± 4.4

0.001※

 SVsd (ml)

63.8 ± 11.8

54.8 ± 12.8

0.002※

COse (L·min−1)

4.9 ± 0.9

4.6 ± 1.0

0.227

 SVRf (dyn·s·cm−5)

1487 ± 295

1582 ± 390

0.243

 SVRI(dyn·s·cm−5·m−2)

2536 ± 475

2711 ± 638

0.184

Parameters in left lateral position

 LVEDAl (cm2)

12.4 ± 1.9

11.8 ± 2.0‡‡

0.217

 VTIl (cm)

22.8 ± 3.7‡‡

23.0 ± 4.0§§

0.798

 SVl (ml)

58.7 ± 11.0‡‡

58.2 ± 12.0§§

0.841

COl (L·min−1)

4.4 ± 0.8‡‡

4.7 ± 1.0

0.098

Percentage change between positions¶¶

 LVEDA%

7.0% ± 19.7%

16.2% ± 20.5%

0.044 ※

 VTI%

 − 7.4% ± 12.6%

8.3% ± 17.8%

 < 0.001※

 SV%

 − 7.2% ± 12.7%

8.2% ± 17.8%

 < 0.001 ※

CO%

 − 9.3% ± 13.0%

4.3% ± 16.5%

 < 0.001※

  1. Values are presented as mean ± standard deviation
  2. aLVOT left ventricular outflow tract, bLVEDA left ventricular end-diastolic area, cVTI velocity time integral, dSV stroke volume, eCO cardiac output, fSVR systemic vascular resistance, jSVRI systemic vascular resistance index
  3. ‡‡P < 0.01 compared to the supine position
  4. §§ P < 0.05 compared to the supine position
  5. ¶¶Percentage change between positions: (value in the left lateral position − value in the supine position)/value in the supine position × 100%
  6. ※the outcome has statistically significant