Skip to main content

Table 2 Hemodynamic measurements before induction, after induction, and after intubation

From: Changes in mean systemic filling pressure as an estimate of hemodynamic response to anesthesia induction using propofol

Parameter

Pre induction

Post induction

Post Intubation

Median (IQR)

Median (IQR)

Pa

Median (IQR)

Pb

HR (beats × min−1)

82 (17)

77 (16)

0.004

90 (27)

0.002

MAP (mmHg)

100 (11)

78 (27)

0.001

89 (29)

0.025

CVP (mmHg)

7 (8.5)

5 (7.5)

0.590

9 (4.5)

0.026

MSFP (mmHg)

25 (7)

17 (9)

0.001

25 (9)

0.003

MSFP-CVP (mmHg)

19 (8)

12 (6)

0.001

19 (7)

0.001

CO (L × min−1)

6.1 (1.6)

4.8 (2.3)

0.002

5 (2.1)

0.798

Rsys (mmHg × min  × L−1)

14.3 (3)

14.7 (6)

0.233

15 (4)

0.156

RVR (mmHg × min  × L−1)

3.1 (2.5)

2.2 (2.2)

0.069

3.3 (1.9)

0.011

Eh

0.73 (0.24)

0.67 (0.35)

0.094

0.70 (0.19)

0.91

  1. IQR interquartile range, HR heart rate, MAP mean arterial pressure, CVP central venous pressure, MSFP mean systemic filling pressure, PVR pressure gradient of venous return (MSFP-CVP), CO cardiac output, Rsys systemic vascular resistance, RVR resistance to venous return, Eh cardiac efficiency
  2. Pa, Wilcoxon test between pre induction values to post induction values
  3. Pb, Wilcoxon test between post induction values to post intubation values