Skip to main content

Table 2 Insertion and ventilation parameters

From: LMA® protector™ in patients undergoing laparoscopic surgeries: a multicenter prospective observational study

Parameters

Result

Successful insertion, n (%)

293 (97.67%)

 1st attempt

251 (85.67%)

 2nd attempt

36 (12.29%)

 3rd attempt

6 (2.05%)

 Failed

7 (2.33%)

Size, n (%)

 3

172 (59.31%)

 4

113 (38.97%)

 5

5 (1.72%)

Size change, n (%)

 No

283 (97.59%)

 Yes

7 (2.41%)

Time of insertion (s)

29.5 [15 to 60]

Easiness of insertion, n (%)

 Easy

41 (14.14%)

 Mild difficulty with resistance

149 (51.38%)

 Moderate difficulty with resistance

97 (33.45%)

 Severe difficulty with resistance

3 (1.03%)

Suprasternal notch test, n (%)

 Positive

219 (75.52%)

 Negative

71 (24.48%)

Successful gastric tube insertion, n (%)

 1st attempt

215 (74.14%)

 2nd attempt

47 (16.21%)

 3rd attempt

21 (7.24%)

 Failed

7 (2.41%)

Oropharyngeal leak pressure (cmH2O)

30.18 ± 5.88

Manipulation of the airway, n (%)

19 (6.48%)

 Adjust the position

13 (68.42%)

 Additional cuff Inflation/deflation

2 (15.38%)

 Device reinsertion

1 (7.69%)

 Replacement of device

3 (23.08%)

Effective ventilation rate, n (%)

290 (96.67%)

Operator’s Satisfaction

8.59 ± 1.02

  1. Data presented as Mean ± SD, median [interquartile range], or absolute numbers/(percentage). Operator’s satisfaction graded on a scale of 0 (worst) to 10 (best) by the anesthetists