Skip to main content

Table 5 Data from intubation in Scenario E: Cervical collar stabilization. Data are presented as median (IQR), or as number (percentage)

From: Comparison of the new flexible tip bougie catheter and standard bougie stylet for tracheal intubation by anesthesiologists in different difficult airway scenarios: a randomized crossover trial

parameter

standard bougie

flexible tip bougie catheter

p-value

Overall success rate, %

32 (100%)

32 (100%)

NS

Duration of 1st intubation attempt, s

46 (38–53)

37 (31.5–46)

< 0.001

Number of intubation attempts (%)

 1

26 (81%)

30 (94%)

 

 2

5 (16%)

1 (3%)

 

 3

1 (3%)

1 (3%)

 

Median (IQR)

1 (1–1)

1 (1–1)

NS

Number of optimization maneuvers (%)

 0

9 (28%)

12 (37%)

 

 1

15 (47%)

17 (53%)

 

 2

8 (25%)

3 (9%)

 

Median (IQR)

1 (0–1.3)

1 (0–1)

NS

Severity of dental compression (%)

 0

0 (0%)

4 (12%)

 

 1

9 (28%)

13 (41%)

 

 2

23 (72%)

15 (47%)

 

Median (IQR)

2 (1–2)

1 (1–2)

NS

Ease of use (1–100)

72 (53–79)

60 (45–71)

0.014

  1. NS Not statistically significant