Skip to main content

Table 2 Multivariate analysis of factors associated with prolonged time on ventilation in the entire population and among patients on maintenance hemodialysis

From: Fluid overload after coronary artery bypass graft in patients on maintenance hemodialysis is associated with prolonged time on mechanical ventilation

Parameter

Standardized β coefficient

Partial correlation

p

Model 1: Entire population

 Σ fluid balance, ml

0.171

0.172

0.004

 Group of patients: reference, CKD3–4 and dialysis

0.182

0.183

0.002

 SOFA on the first day after surgery

0.312

0.314

0.0001

Model 2: Patients on hemodialysis

 Σ fluid balance, ml

0.284

0.497

0.049

 Time from surgery to 1st HD, h

0.289

0.332

0.038

 SOFA without renal component

0.549

0.627

0.0001

  1. Model 1: r = 0.369, r2 = 0.136 and adjusted r2 = 0.130; p = 0.0001. Other variables in the model: anesthesia time, noradrenaline and dobutamine dose 24 h after surgery
  2. Model 2: r = 0.757, r2 = 0.574 and adjusted r2 = 0.524; p = 0.0001. Other variable in the model: age
  3. HD hemodialysis, SOFA Sequential Organ Failure Assessment