Table 2 Ablation data in enrolled patients with catheter ablation

From: Laryngeal mask versus facemask in the respiratory management during catheter ablation

Variable

Facemask group (n = 10)

Laryngeal mask group (n = 14)

p value

Total duration of procedure, min

194.5 ± 29.1

162.5 ± 39.1

0.037

Total fluoroscopic duration, min

82.9 ± 17.6

55.9 ± 18.5

0.002

Duration of RF energy, min

40.3 ± 7.6

32.8 ± 9.0

0.042

Delivered RF energy, (×103J)

73.5 ± 16.2

58.1 ± 16.1

0.030

Total ablation points, (points)

86.2 ± 14.0

64.6 ± 23.7

0.017

  1. The values are reported as the mean ± standard deviation