Skip to main content

Table 2 Comparative data of PLMA insertions. Data are mean ± standard deviation, frequencies or median (min-max)

From: Comparison of videolaryngoscope-guided versus standard digital insertion techniques of the ProSeal™ laryngeal mask airway: a prospective randomized study

Variables

Group V (n = 60)

Group D (n = 59)

P value

Effect size with 95% C.I.

Insertion success (n)

 First attempt

60

53 (89.8%)

 

0.19 (0.01–0.36)a

 Second attempt

0

4 (6.7%)

0.029

0.09 (−0.08–0.27)b

 Third attempt

0

1 (1.6%)

 

NaNc

 Overall

60/60 (100%)

59/60 (98.3%)

  

Insertion time (sec)

38.36 ± 6.44

28.59 ± 9.44

< 0.001

 

Oropharyngeal leak pressure (cmH2O)

30.28 ± 8.3

29.86 ± 6.91

0.764

 

Leak volume (L)

0.13 ± 0.15

0.19 ± 0.26

0.143

 

Fibreoptic score

4 (3–4)

3 (1–4)

< 0.001

 

Peak inspiratuar pressure (cmH2O)

11.21 ± 2.94

13.01 ± 3.73

0.004

 

Orogastric tube insertion

 easy / difficult / impossible

60/0/0

46/11/2

< 0.001

 
  1. Group V, videolaryngoscope-guided group; Group D, standard digital group; a First and second attempts by the groups (2 × 2 crossstab); b First and third attempts by the groups (2 × 2 crossstab); c second and third attempts by the groups (2 × 2 crossstab) can not be computed