Skip to main content

Table 1 Comparison between fluid responding status (FRS) and Fluid non-Responding Status (FnRS). Values presented as Mean (SD)

From: The validity of central venous to arterial carbon dioxide difference to predict adequate fluid management during living donor liver transplantation. A prospective observational study

 

Fluid Responding Status (N = 20)

Fluid non-Responding Status (N = 47)

P value

C(v-a) CO2gap

5.5(2.6)

4.3(3.2) *

0.016

Pulm(P-a) CO2 gap

5.16(4.24)

3.96(2.89)

0.18

Lactate

3.9(1.6)

3.5(2.3)

0.18

CO

6.7(2.6)

8.8(3.4)

0.06

Scvo2

80.3(12.1)

82.5(11.9)

0.32

  1. *P value = 0.016 with significant difference between two groups. Mann Whitney test. N Number of data points, C(v-a) CO2 central venous to arterial carbon dioxide tension difference, Pulm(P-a) CO2 mixed venous to arterial carbon dioxide tension difference, CO cardiac output, Scvo2 central venous oxygen saturation