Skip to main content

Table 2 Differences in VT and PEEP settings between the correct and incorrect answer groups

From: Application of intraoperative lung-protective ventilation varies in accordance with the knowledge of anaesthesiologists: a single-Centre questionnaire study and a retrospective observational study

 

Non-conceptual

Conceptual

p-value

OR (95% CI)

No.

19

63

  

1st & 2nd year residents

3

13

0.040

 

3rd & 4th year residents

4

17

Fellows

3

20

Assistant Professors

1

8

Associate Professors & Professors

8

5

VT in laparoscopic surgeries (mL/kg IBW)

9.64 (8.81–10.25)

8.37 (7.79–9.22)

< 0.001

 

PEEP in laparoscopic surgeries, n (%)

16/19 (84.2%)

59/62 (95.2%)

0.138

0.27 (0.05–1.47)

VT in non-laparoscopic surgeries (mL/kg IBW)

6.72 (6.04–7.30)

7.06 (6.29–7.55)

0.109

 

PEEP in non-laparoscopic surgeries, n (%)

14/19 (73.7%)

54/63 (85.7%)

0.296

2.14 (0.62–7.41)

VT in obese patients (mL/kg IBW)

8.80 (7.58–9.10)

7.81 (7.58–8.34)

0.014

 

PEEP in obese patients, n (%)

14/18 (77.8%)

60/62 (96.8%)

0.021

8.57 (1.43–51.56)

Conventional PEEP

13/19 (68.4%)

57/63 (90.5%)

0.027

4.39 (1.22–15.80)

  1. VT, tidal volume; PEEP, positive end-expiratory pressure; OR, odds ratio; IBW, ideal body weight, CI, confidence interval