Table 3 Ventilator setting during OLV of patients with and without PPCs

From: Associations between intraoperative ventilator settings during one-lung ventilation and postoperative pulmonary complications: a prospective observational study

 

Patients with PPCs (N = 51)

Patients without PPCs (N = 146)

P value

Ventilator setting during OLV

 Mode (PCV) - no. (%)

46 (90.2)

135 (92.5)

0.62

 TWA FIO2

0.85 (0.73-1.0)

0.77 (0.63-0.89)

0.0032

 TWA VT - ml/kg

6.2 (5.2-7.4)

6.1 (5.4-7.0)

0.8495

 TWA ΔP - cmH2O

18 (15-21)

16 (15-18)

0.0717

 TWA PEEP - cmH2O

4 (4-5)

4 (4-5)

0.1504