Skip to main content

Table 4 Respiratory data

From: A randomized prospective controlled trial comparing the laryngeal tube suction disposable and the supreme laryngeal mask airway: the influence of head and neck position on oropharyngeal seal pressure

 

SLMA (n = 80)

LTS-D (n = 80)

p value

Ventilation inspirium (ml)

501 ± 125

524 ± 138

†0.2787

Ventilation expirium (ml)

444 ± 110

475 ± 123

†0.0965

Ventilation delta (ml)

57 ± 35

48 ± 26

†0.0792

O2 Saturation (%)

99 ± 0.8

99 ± 0.8

†0.8632

ETCO2 (mmHg)

33 ± 3

34 ± 4

†0.4356

Peak (cmH2O)

16 ± 3

18 ± 4

†0.0060**

Peep (cmH2O)

2 ± 0.7

2 ± 0.6

†0.2631

P plat (cmH2O)

11 ± 2

12 ± 2

†0.0080**

  1. Data are mean ± SD