Table 1 The effect of anesthetic induction on peripheral and central (aortic) blood pressures, ejection duration and pressure augmentation

From: Non-invasive pulse wave analysis for monitoring the cardiovascular effects of CO2pneumoperitoneum during laparoscopic cholecystectomy- a prospective case-series study

 

Before induction

After induction

p-value

Peripheral blood pressure

Systolic

132.47 ± 18.87

116.80 ± 18.61

P < 0.001

Diastolic

78.60 ± 10.40

72.71 ± 13.54

0.01

Pulse pressure

52.12 ± 16.12

43.65 ± 11.96

P < 0.01

Central (aortic) blood pressure

Systolic

120.80 ± 19.10

106.77 ± 18.78

P < 0.001

Diastolic

80.00 ± 10.38

73.88 ± 13.79

P < 0.01

Pulse pressure

41.05 ± 14.70

33.11 ± 11.08

P < 0.001

Ejection duration

41.0 ± 4.93

38.40 ± 6.71

0.01

Pressure augmentation

Augmentation pressure

10.52 ± 8.52

7.31 ± 5.59

P < 0.01

Augmentation index

23.62 ± 10.58

18.97 ± 10.80

P < 0.01

Subendocardial viability ratio (%)

121.85 ± 22.7

142.5 ± 38.2

P < 0.01

  1. Means and standard deviations are shown.