From: Non-invasive detection of hypovolemia or fluid responsiveness in spontaneously breathing subjects
AUC (CI) | Cut-off | Sensitivity (%) | Specificity (%) | |
---|---|---|---|---|
SV | 0.97 (0.85-1.0) | 56 ml | 94 | 95 |
PP | 0.88 (0,73-0.97) | 53 mmHg | 88 | 85 |
SVV 6 | 0.83 (0.67-0.94) | 16% | 81 | 75 |
PPV 6 | 0.78 (0.61-0.9) | 13% | 81 | 65 |
SVV 15* | 0.69 (0.51-0.83) | 13% | 69 | 70 |
PPV 15 | 0.83 (0.66-0.93) | 8% | 81 | 75 |