Skip to main content

Table 3 Regression analysis of intraoperative ventilator settings on postoperative pulmonary complications

From: Intraoperative mechanical power and postoperative pulmonary complications in low-risk surgical patients: a prospective observational cohort study

 

No PPC

PPC

Odds ratio

p-value

[95% CI]

Simple logistic regression

 VT/IBW (ml/kg)

8.6 ± 1.4

9.1 ± 1.9

1.2 [1.0–1.5]

0.024

 Pplateau (cmH2O)

16.1 ± 4.3

17.4 ± 5.5

1.1 [0.9–1.1]

0.059

 MP (J/min)

11.1 ± 3.7

12.9 ± 4.5

1.1 [1.0–1.2]

0.003

Multiple logistic regression

 VT/IBW (ml/kg)

8.6 ± 1.4

9.1 ± 1.9

1.1 [0.9–1.4]

0.187

 Pplateau (cmH2O)

16.1 ± 4.3

17.4 ± 5.5

1.0 [0.9–1.1]

0.982

 MP (J/min)

11.1 ± 3.7

12.9 ± 4.5

1.1 [1.0–1.2]

0.036

  1. Data is presented as mean ± standard deviation or odds ratio [confidence interval]
  2. VT/IBW Tidal volume/ideal body weight, Pplateau Plateau pressure, MP Mechanical power