Skip to main content

Table 2 Variation for the cardiac thermodilution maesurements at the same body temperature during cooling and rewarming periods

From: Cardiac condition during cooling and rewarming periods of therapeutic hypothermia after cardiopulmonary resuscitation

Cooling (C)/Rewarming (RW) periods

Mean. ± s.d.

p

 

Mean. ± s.d.

p

BTbasal-C/BTbasal-RW

SAP

10,7 ± 33,8

0,094

SVRI

792 ± 672

0,000

 BT36-C/BT36-RW

12,9 ± 29,5

0,024

1089 ± 1791

0,002

 BT35-C/BT35-RW

14,8 ± 29,1

0,009

1178 ± 1444

0,000

 BT34-C/BT34-RW

11,9 ± 29,9

0,038

777 ± 1094

0,001

 BT33-C/BT33-RW

−6,7 ± 30,7

0,242

72 ± 1325

0,768

BTbasal-C/BTbasal-RW

DAP

8,2 ± 19,7

0,030

CO

−1,1 ± 1,6

0,001

 BT36-C/BT36-RW

10,7 ± 18,3

0,003

−0,8 ± 1,6

0,009

 BT35-C/BT35-RW

11,0 ± 19,6

0,005

−1,1 ± 1,6

0,000

 BT34-C/BT34-RW

8,1 ± 15,7

0,008

−0,8 ± 1,4

0,003

 BT33-C/BT33-RW

2,2 ± 19,2

0,529

−1,0 ± 1,5

0,002

BTbasal-C/BTbasal-RW

MAP

6,7 ± 24,4

0,141

CI

−0,6 ± 1,0

0,002

 BT36-C/BT36-RW

11,8 ± 19,9

0,003

−0,5 ± 0,8

0,001

 BT35-C/BT35-RW

12,0 ± 19,8

0,002

−0,7 ± 0,9

0,000

 BT34-C/BT34-RW

9,1 ± 19,7

0,017

−0,5 ± 0,8

0,002

 BT33-C/BT33-RW

−2,3 ± 24,2

0,602

−0,5 ± 0,9

0,012

BTbasal-C/BTbasal-RW

HR

4,1 ± 19,9

0,273

GEDI

22,0 ± 140,2

0,397

 BT36-C/BT36-RW

3,8 ± 24,2

0,397

−72,3 ± 167,1

0,025

 BT35-C/BT35-RW

−3,4 ± 18,5

0,326

−83,8 ± 285,3

0,118

 BT34-C/BT34-RW

−2,7 ± 16,5

0,384

−18,6 ± 171,8

0,557

 BT33-C/BT33-RW

2,7 ± 19,5

0,450

−0,9 ± 117,5

0,966

BTbasal-C/BTbasal-RW

CVP

0,8 ± 7,2

0,562

ELWI

0,1 ± 2,9

0,902

 BT36-C/BT36-RW

1,8 ± 5,4

0,074

1,3 ± 4,1

0,083

 BT35-C/BT35-RW

1,8 ± 5,3

0,081

1,0 ± 3,8

0,148

 BT34-C/BT34-RW

1,9 ± 5,6

0,078

 

0,6 ± 3,6

0,394

 BT33-C/BT33-RW

1,7 ± 5,6

0,111

 

0,7 ± 2,8

0,206

  1. Paired sample t test.
  2. SAP measurements did not demonstrate any difference at Tbasal-C/Tbasal-RW and 33°C (p > 0.05). SAP values during rewarming at 34°C, 35°C, 36°C were lower as compared to measurements in cooling period (p < 0.05). DAP measurements did not demonstrate any difference at 33°C (p > 0.05). DAP values during rewarming at Tbasal-RW, 34°C, 35°C, 36°C were lower as compared to the measurements during cooling period. MAP meaurements did not demonstrate any difference at Tbasal-C/Tbasal-RW and 33°C (p < 0.05). MAP values during rewarming at 34°C, 35°C, 36°C were lower as compared to measurements during cooling period (p < 0.05). HR and CVP measurement values at the same body temperature during rewarming and cooling period did nor demonstrate any difference (p > 0.05). CO measurements were higher during the rewarming period (p < 0.05). CI measurements were higher during the rewarming period (p < 0.05). GEDI and ELWI measurements during rewarming and cooling periods did not demonstrate any difference at the same body temperatures (p > 0.05). SVRI measurements during rewarming and cooling periods at 33°C did nor demonstrate any difference (p > 0.05). SVRI values during rewarming period at 34°C, 35°C, 36°C and Tbasal-RW period were lower (p < 0.05).
  3. C: Cooling, RW: Rewarning, BT: Body temperature, SAP: Systolic arterial pressure, DAP: Diastolic arterial pressure, MAP: Mean arterial pressure, HR: Heart rate, CVP: Central venous pressure, SVRI: Systemic vascular resistance index, CO: Cardiac output, CI: Cardiac index, GEDI: Global end-diastolic volume index, ELWI: Extravascular lung water index.