Skip to main content

Table 3 Airway leak of LMA ProSeal and peak airway pressure at four time points

From: AutoFlow® versus volume-controlled ventilation for laparoscopic gynecological surgery using LMA® ProSeal™: a randomized controlled trial

 

AutoFlow group (n = 40)

VCV group (n = 39)

P value

1. Airway leak

0 (0)

0 (0)

 

2. Airway leak

0 (0)

0 (0)

 

3. Airway leak

2 (5)

0 (0)

0.49

4. Airway leak

4 (10)

2 (5)

0.68

1. PAWP (cmH2O)

12 [12–13]

13 [12–14]

0.013

2. PAWP (cmH2O)

12 [12–13]

13 [13–14]

0.004

3. PAWP (cmH2O)

13 [12–15]

16 [12–17]

0.001

4. PAWP (cmH2O)

16 [15–18]

18 [17–19]

< 0.001

  1. 1, One min after insertion of the gastric tube; 2, Two min after intravenous administration of neuromuscular blocking drug; 3, One min after initiation of pneumoperitoneum; 4, One min after change to the Trendelenburg position. Data are shown as number (proportion), median [interquartile range].
  2. VCV Volume-controlled ventilation, PAWP Peak airway pressure