Skip to main content

Table 2 Catheter- and subject-related outcomes for the Dermabond as compared with the control groups

From: Decreasing leakage during continuous femoral nerve catheter fixation using 2-octyl cyanoacrylate glue (Dermabond®): a randomized controlled trial

  Dermabond group Control group P-value
Leakage, n (%)
24 h after operation 0 (0%) 14 (93.33%) < 0.001*
48 h after operation 0 (0%) 15 (100%) < 0.001*
Displacement, n (%)
 24 h after operation 1 (6.67%) 11 (73.33%) < 0.001*
 48 h after operation 1 (6.67%) 14 (93.33%) < 0.001*
Change dressing, n (%)
 24 h after operation 0 1 (0–3) 0.001
 48 h after operation 0 1 (0–4) < 0.001
NRS
 24 h after operation 2 (0–7) 2 (0–8) 0.539
 48 h after operation 2 (0–7) 2 (0–7) 0.806
Satisfaction score, mean ± SD 9.13 ± 1.13 9.07 ± 1.28 0.881
  1. NRS Numeric rating scale, SD Standard deviation