Skip to main content

Table 2 Blood gas values and procedure duration among three groups

From: High frequency jet ventilation through mask contributes to oxygen therapy among patients undergoing bronchoscopic intervention under deep sedation

Patients values

Group COT(n = 50)

Group NFJV(n = 50)

Group HFJV(n = 50)

P Value

PaO2 (mmHg)

176.3 ± 73.4b

192.0 ± 88.4b

251.7 ± 86.6ac

< 0.001

PaCO2(mmHg)

59.2 ± 15.2

59.8 ± 14.1

59.6 ± 10.7

0.972

Pondus hydrogenii

7.3 ± 0.1

7.3 ± 0.1

7.3 ± 0.1

0.647

Glucose (mmol/l)

6.4 ± 1.8

6.9 ± 1.9

7.0 ± 2.1

0.203

Lactic acid (mmol/l)

1.1 ± 0.4b

1.4 ± 0.7

1.6 ± 1.1a

0.005

Procedure duration (min)

27.9 ± 8.8b

29.3 ± 8.5

33.0 ± 12.7a

0.038

  1. *Data were presented as mean ± standard deviation (median, range). a was statistically significant compared with COT group, b was statistically significant compared with HFJV group, c was statistically significant compared with NFJV group
  2. There were significant differences among the three groups in PaO2, lactic acid and procedure duration (P < 0.001, P = 0.005, P = 0.038). Moreover, PaO2 of HFJV group was significantly higher than that of COT and NFJV group. Lactic acid and procedure duration of HFJV group was significantly higher than that of COT group
  3. COT conventional oxygen therapy; NFJV normal frequency jet ventilation; HFJV high frequency jet ventilation