Skip to main content

Table 4 Multiple logistic regression model for predicting immediately postoperative dressing change (per-protocol analysis)

From: Effectiveness of securing central venous catheters with topical tissue adhesive in patients undergoing cardiac surgery: a randomized controlled pilot study

Independent variables

Relative risk (95%CI)

P

Topical adhesive applied a

0.25 (0.07–0.87)

0.029*

Double catheters b

1.12 (0.38–3.30)

0.843

No Intraoperative LPRC transfusion

1.80 (0.60–5.40)

0.295

  1. CI confidence interval, LPRC leukocyte-poor red blood cells
  2. a Referenced to standard control group (SC)
  3. b Referenced to single catheter