Skip to main content

Table 2 Respiratory effects of the alveolar recruitment maneuver (n=31)

From: Evaluation of alveolar recruitment maneuver on respiratory resistance during general anesthesia: a prospective observational study

 

Pre-ARM

Post-ARM

P value

MostGraph® measurement

 Tidal volume (mL)

447±55

458±53

0.077

 R5 (cmH2O/L/second)

7.3±1.6

6.4±1.7

0.001

Ventilator measurement

 Tidal volume setting (mL)

497±53

497±53

NA

 Actual tidal volume (mL)

480±56

488±56

0.026

 Peak inspiratory pressure (cmH2O)

15.5±1.7

15.0±1.5

<0.001

 Plateau pressure (cmH2O)

13.6±1.6

13.0±1.4

<0.001

 PEEP (cmH2O)

5±0

5±0

NA

 Cdyn (mL/cmH2O)

47.0±8.8

50.0±8.9

<0.001

 Cst (mL/cmH2O)

58.3±13.9

63.1±13.3

<0.001

  1. ARM Alveolar recruitment maneuver, Cdyn Dynamic respiratory compliance, Cst Static pulmonary compliance, NA Not applicable, PEEP Positive end-expiratory pressure.