Skip to main content

Table 2 Clinical predictors of difficult airway

From: A comparison of blind intubation with the intubating laryngeal mask FASTRACH™ and the intubating laryngeal mask Ambu Aura-i™ a prospective randomised clinical trial

Combination LMA/tube

Subgroup 1a)

Subgroup 1b)

Subgroup 2a)

Subgroup 2b)

Total

Aura-i/Rüsch

Aura-i/ETT

Fastrach/Rüsch

Fastrach/ETT

Mallampati I/II/III

7/9/3

11/8/2

13/7/1

10/5/4

41/29/10

(37%/47%/16%)

(52%/38%/10%)

(62%/33%/5%)

(53%/26%/21%)

(51%/36%/13%)

Interincisor distance [cm]

4.3 ± 0.7

4.2 ± 0.5

4.4 ± 0.7

4.3 ± 0.7

4.3 ± 0.6

[3.5–6.2]

[3.2–5.5]

[3.2–6.0]

[3.5–5.8]

[3.2–6.2]

Thyromental dist. (Patil) [cm]

7.8 ± 1.9

7.5 ± 1.1

8.2 ± 1.1

7.6 ± 1.5

7.8 ± 1.4

[4–11]

[4.8–10]

[5.5–10]

[4.5–11]

[4–11]

  1. Values are absolute values (percent) and mean ± SD [minimum – maximum]. No significant differences