Skip to main content

Table 3 Sensory and motor block characteristics

From: Impedance cardiography as tool for continuous hemodynamic monitoring during cesarean section: randomized, prospective double blind study

 

6 mg Levobupivacaine (n = 32)

8 mg Levobupivacaine (n = 30)

P value

Maximal sensory block height (n)

 T1 dermatome

27

23

.999

 T2 dermatome

2

0

.999

 C8 dermatome

3

7

.999

Onset time of sensory block (min)

3.2 ± 1.4

2.8 ± .9

.841

Offset time of sensory block (min)

157.2 ± 42

163.6 ± 33

.735

Regression time of 2 dermatomes (min)

62.4 ± 20

58 ± 14

.547

Motor block

 Bromage score 0 (n,%)

23 (71.9%)

6 (18.7%)

.001

 Bromage score 1 (n, %)

4 (12.5%)

7 (23.3%)

 

 Bromage score 2 (n, %)

5 (15.6%)

14 (46.7%)

 

 Bromage score 3 (n, %)

0 (0%)

3 (10%)

 

Onset time of motor block (min)

1.2 ± .4

1.9 ± 1.6

.228

Offset time of motor block (min)

60 ± 18

57 ± 7

.556

  1. Data are presented as mean ± standard deviation or number and percentage of patients