TY - JOUR AU - Beitz, A. AU - Riphaus, A. AU - Meining, A. AU - Kronshage, T. AU - Geist, C. AU - Wagenpfeil, S. PY - 2012 DA - 2012// TI - Capnographic monitoring reduces the incidence of arterial oxygen desaturation and hypoxemia during propofol sedation for colonoscopy: a randomized, controlled study (colocap study) JO - Am J Gastroenterol VL - 107 UR - https://doi.org/10.1038/ajg.2012.136 DO - 10.1038/ajg.2012.136 ID - Beitz2012 ER - TY - JOUR AU - Ramsay, M. A. AU - Newman, K. B. AU - Jacobson, R. M. AU - Richardson, C. T. AU - Rogers, L. AU - Brown, B. J. PY - 2014 DA - 2014// TI - Sedation levels during propofol administration for outpatient colonoscopies JO - Proc (Bayl Univ Med Cent) VL - 27 ID - Ramsay2014 ER - TY - JOUR AU - Hart, R. AU - Classen, M. PY - 1990 DA - 1990// TI - Complications of diagnostic gastrointestinal endoscopy JO - Endoscopy VL - 22 UR - https://doi.org/10.1055/s-2007-1010734 DO - 10.1055/s-2007-1010734 ID - Hart1990 ER - TY - JOUR AU - Arrowsmith, J. B. AU - Gerstman, B. B. AU - Fleischer, D. E. AU - Benjamin, S. B. PY - 1991 DA - 1991// TI - Results from the American Society for Gastrointestinal Endoscopy/U.S. Food and Drug Administration collaborative study on complication rates and drug use during gastrointestinal endoscopy JO - Gastrointest Endosc VL - 37 UR - https://doi.org/10.1016/S0016-5107(91)70773-6 DO - 10.1016/S0016-5107(91)70773-6 ID - Arrowsmith1991 ER - TY - JOUR AU - Daneshmend, T. K. AU - Bell, G. D. AU - Logan, R. F. PY - 1991 DA - 1991// TI - Sedation for upper gastrointestinal endoscopy: results of a nationwide survey JO - Gut VL - 32 UR - https://doi.org/10.1136/gut.32.1.12 DO - 10.1136/gut.32.1.12 ID - Daneshmend1991 ER - TY - JOUR AU - Sharma, V. K. AU - Nguyen, C. C. AU - Crowell, M. D. AU - Lieberman, D. A. AU - de Garmo, P. AU - Fleischer, D. E. PY - 2007 DA - 2007// TI - A national study of cardiopulmonary unplanned events after GI endoscopy JO - Gastrointest Endosc VL - 66 UR - https://doi.org/10.1016/j.gie.2006.12.040 DO - 10.1016/j.gie.2006.12.040 ID - Sharma2007 ER - TY - JOUR AU - Dumonceau, J. M. AU - Riphaus, A. AU - Aparicio, J. R. AU - Beilenhoff, U. AU - Knape, J. T. AU - Ortmann, M. PY - 2010 DA - 2010// TI - European Society of Gastrointestinal Endoscopy, European Society of Gastroenterology and Endoscopy Nurses and associates, and the European Society of Anaesthesiology Guideline: non-anaesthesiologist administration of propofol for gi endoscopy JO - Eur J Anaesthesiol VL - 27 UR - https://doi.org/10.1097/EJA.0b013e32834136bf DO - 10.1097/EJA.0b013e32834136bf ID - Dumonceau2010 ER - TY - JOUR PY - 2002 DA - 2002// TI - Practice guidelines for sedation and analgesia by non-anesthesiologists JO - Anesthesiology VL - 96 UR - https://doi.org/10.1097/00000542-200204000-00031 DO - 10.1097/00000542-200204000-00031 ID - ref8 ER - TY - JOUR AU - Vargo, J. J. AU - Zuccaro, G. AU - Dumot, J. A. AU - Conwell, D. L. AU - Morrow, J. B. AU - Shay, S. S. PY - 2002 DA - 2002// TI - Automated graphic assessment of respiratory activity is superior to pulse oximetry and visual assessment for the detection of early respiratory depression during therapeutic upper endoscopy JO - Gastrointest Endosc VL - 55 UR - https://doi.org/10.1067/mge.2002.124208 DO - 10.1067/mge.2002.124208 ID - Vargo2002 ER - TY - JOUR AU - Burton, J. H. AU - Harrah, J. D. AU - Germann, C. A. AU - Dillon, D. C. PY - 2006 DA - 2006// TI - Does end-tidal carbon dioxide monitoring detect respiratory events prior to current sedation monitoring practices? JO - Acad Emerg Med VL - 13 UR - https://doi.org/10.1111/j.1553-2712.2006.tb00999.x DO - 10.1111/j.1553-2712.2006.tb00999.x ID - Burton2006 ER - TY - JOUR AU - Metzner, J. AU - Posner, K. L. AU - Domino, K. B. PY - 2009 DA - 2009// TI - The risk and safety of anesthesia at remote locations: the US closed claims analysis JO - Curr Opin Anaesthesiol VL - 22 UR - https://doi.org/10.1097/ACO.0b013e32832dba50 DO - 10.1097/ACO.0b013e32832dba50 ID - Metzner2009 ER - TY - JOUR AU - Qadeer, M. A. AU - Vargo, J. J. AU - Dumot, J. A. AU - Lopez, R. AU - Trolli, P. A. AU - Stevens, T. PY - 2009 DA - 2009// TI - Capnographic monitoring of respiratory activity improves safety of sedation for endoscopic cholangiopancreatography and ultrasonography JO - Gastroenterology VL - 136 UR - https://doi.org/10.1053/j.gastro.2009.02.004 DO - 10.1053/j.gastro.2009.02.004 ID - Qadeer2009 ER - TY - JOUR AU - Lightdale, J. R. AU - Goldmann, D. A. AU - Feldman, H. A. AU - Newburg, A. R. AU - DiNardo, J. A. AU - Fox, V. L. PY - 2006 DA - 2006// TI - Microstream capnography improves patient monitoring during moderate sedation: a randomized, controlled trial JO - Pediatrics VL - 117 UR - https://doi.org/10.1542/peds.2005-1709 DO - 10.1542/peds.2005-1709 ID - Lightdale2006 ER - TY - JOUR AU - Friedrich-Rust, M. AU - Welte, M. AU - Welte, C. AU - Albert, J. AU - Meckbach, Y. AU - Herrmann, E. PY - 2014 DA - 2014// TI - Capnographic monitoring of propofol-based sedation during colonoscopy JO - Endoscopy VL - 46 UR - https://doi.org/10.1055/s-0034-1365434 DO - 10.1055/s-0034-1365434 ID - Friedrich-Rust2014 ER - TY - JOUR AU - Casati, A. AU - Gallioli, G. AU - Scandroglio, M. AU - Passaretta, R. AU - Borghi, B. AU - Torri, G. PY - 2000 DA - 2000// TI - Accuracy of end-tidal carbon dioxide monitoring using the NBP-75 microstream capnometer. A study in intubated ventilated and spontaneously breathing nonintubated patients JO - Eur J Anaesthesiol VL - 17 ID - Casati2000 ER - TY - JOUR AU - Kasuya, Y. AU - Akca, O. AU - Sessler, D. I. AU - Ozaki, M. AU - Komatsu, R. PY - 2009 DA - 2009// TI - Accuracy of postoperative end-tidal pCO2 measurements with mainstream and sidestream capnography in non-obese patients and in obese patients with and without obstructive sleep apnea JO - Anesthesiology VL - 111 UR - https://doi.org/10.1097/ALN.0b013e3181b060b6 DO - 10.1097/ALN.0b013e3181b060b6 ID - Kasuya2009 ER - TY - JOUR AU - Krauss, B. AU - Hess, D. R. PY - 2007 DA - 2007// TI - Capnography for procedural sedation and analgesia in the emergency department JO - Ann Emerg Med VL - 50 UR - https://doi.org/10.1016/j.annemergmed.2006.10.016 DO - 10.1016/j.annemergmed.2006.10.016 ID - Krauss2007 ER - TY - JOUR AU - Stokes, M. E. AU - Ye, X. AU - Shah, M. AU - Mercaldi, K. AU - Reynolds, M. W. AU - Rupnow, M. F. PY - 2011 DA - 2011// TI - Impact of bleeding-related complications and/or blood product transfusions on hospital costs in inpatient surgical patients JO - BMC Health Serv Res VL - 11 UR - https://doi.org/10.1186/1472-6963-11-135 DO - 10.1186/1472-6963-11-135 ID - Stokes2011 ER - TY - STD TI - Parsons LS. Reducing bias in a propensity score matched-pair sample using greedy matching techniques. SUGI 26 Proceedings 2001. ID - ref19 ER - TY - JOUR AU - Austin, P. C. PY - 2009 DA - 2009// TI - Balance diagnostics for comparing the distribution of baseline covariates between treatment groups in propensity-score matched samples JO - Stat Med VL - 28 UR - https://doi.org/10.1002/sim.3697 DO - 10.1002/sim.3697 ID - Austin2009 ER - TY - JOUR AU - Tobias, J. D. AU - Leder, M. PY - 2011 DA - 2011// TI - Procedural sedation: a review of sedative agents, monitoring, and management of complications JO - Saudi J Anaesth VL - 5 UR - https://doi.org/10.4103/1658-354X.87270 DO - 10.4103/1658-354X.87270 ID - Tobias2011 ER - TY - JOUR AU - Pino, R. M. PY - 2007 DA - 2007// TI - The nature of anesthesia and procedural sedation outside of the operating room JO - Curr Opin Anaesthesiol VL - 20 UR - https://doi.org/10.1097/ACO.0b013e32827035c7 DO - 10.1097/ACO.0b013e32827035c7 ID - Pino2007 ER - TY - JOUR AU - Arakawa, H. AU - Kaise, M. AU - Sumiyama, K. AU - Saito, S. AU - Suzuki, T. AU - Tajiri, H. PY - 2013 DA - 2013// TI - Does pulse oximetry accurately monitor a patient's ventilation during sedated endoscopy under oxygen supplementation? JO - Singap Med J VL - 54 UR - https://doi.org/10.11622/smedj.2013075 DO - 10.11622/smedj.2013075 ID - Arakawa2013 ER - TY - JOUR AU - Bhananker, S. M. AU - Posner, K. L. AU - Cheney, F. W. AU - Caplan, R. A. AU - Lee, L. A. AU - Domino, K. B. PY - 2006 DA - 2006// TI - Injury and liability associated with monitored anesthesia care: a closed claims analysis JO - Anesthesiology VL - 104 UR - https://doi.org/10.1097/00000542-200602000-00005 DO - 10.1097/00000542-200602000-00005 ID - Bhananker2006 ER - TY - JOUR AU - Anderson, J. L. AU - Junkins, E. AU - Pribble, C. AU - Guenther, E. PY - 2007 DA - 2007// TI - Capnography and depth of sedation during propofol sedation in children JO - Ann Emerg Med VL - 49 UR - https://doi.org/10.1016/j.annemergmed.2006.06.011 DO - 10.1016/j.annemergmed.2006.06.011 ID - Anderson2007 ER - TY - JOUR AU - Deitch, K. AU - Miner, J. AU - Chudnofsky, C. R. AU - Dominici, P. AU - Latta, D. PY - 2010 DA - 2010// TI - Does end tidal CO2 monitoring during emergency department procedural sedation and analgesia with propofol decrease the incidence of hypoxic events? A randomized, controlled trial JO - Ann Emerg Med VL - 55 UR - https://doi.org/10.1016/j.annemergmed.2009.07.030 DO - 10.1016/j.annemergmed.2009.07.030 ID - Deitch2010 ER - TY - JOUR AU - Deitch, K. AU - Chudnofsky, C. R. AU - Dominici, P. PY - 2008 DA - 2008// TI - The utility of supplemental oxygen during emergency department procedural sedation with propofol: a randomized, controlled trial JO - Ann Emerg Med VL - 52 UR - https://doi.org/10.1016/j.annemergmed.2007.11.040 DO - 10.1016/j.annemergmed.2007.11.040 ID - Deitch2008 ER - TY - STD TI - ASA Standards for Basic Anesthetic Monitoring, Committee of Origin: Standards and Practice Parameters. http://www.asahq.org/~/media/sites/asahq/files/public/resources/standards-guidelines/standards-for-basic-anesthetic-monitoring.pdf. Accessed Mar 2017. UR - http://www.asahq.org/~/media/sites/asahq/files/public/resources/standards-guidelines/standards-for-basic-anesthetic-monitoring.pdf ID - ref28 ER - TY - JOUR AU - Saunders, R. AU - Erslon, M. AU - Vargo, J. PY - 2016 DA - 2016// TI - Modeling the costs and benefits of capnography monitoring during procedural sedation for gastrointestinal endoscopy JO - Endosc Int Open VL - 4 UR - https://doi.org/10.1055/s-0042-100719 DO - 10.1055/s-0042-100719 ID - Saunders2016 ER - TY - STD TI - Jopling M, Trost D, Kofol T, Warner E. Capnography monitoring in procedural sedation: a hospital-wide cost-avoidance model. Presented at 24th Society for Technology in Anesthesia (STA) Annual Meeting. January 7–10, 2015, Phoenix, Arizona. https://www.stahq.org/files/2214/4535/8382/19_Abstract_Jopling.pdf. Accessed Nov 2017. UR - https://www.stahq.org/files/2214/4535/8382/19_Abstract_Jopling.pdf ID - ref30 ER -