Table 2 Clinical outcomes

From: Two-minute disconnection technique with a double-lumen tube to speed the collapse of the non-ventilated lung for one-lung ventilation in thoracoscopic surgery

Variable

Group N (n = 20)

Group C (n = 20)

P

Time required for lung collapse (min)

15 ± 3.7

22 ± 3.6

<0.001

Time required for pleural opening (s)

85 ± 6.7

88 ± 6.6

=0.176

Overall satisfaction of the surgeon

9 ± 0.6

7 ± 1.2

<0.001

Intraoperative hypoxaemia (n)

2

1

=1.000

Intraoperative use of CPAP during OLV (n)

2

1

=1.000

Duration of anaesthesia (min)

124 ± 27.9

125 ± 28.9

=0.847

Duration of awakening (min)

18 ± 3.2

19 ± 5.3

=0.616

  1. The data are expressed as the mean ± SD values or the number of patients. CPAP, continuous positive airway pressure; OLV, one-lung ventilation. P < 0.05 was statistically significant compared with group C