Skip to main content

Table 1 Hemodynamic data during normovolemia (BL), hypovolemia (BW), pulmonary embolism (PE) and volume loading (VOL)

From: Pulmonary hypertension attenuates the dynamic preload indicators increase during experimental hypovolemia

 

BL

BW

PE

VOL

AoF (mL . min-1)

70 ± 8

53 ± 7

34 ± 10*

38 ± 10*

HR (bpm)

191 ± 37

180 ± 35

153 ± 37

152 ± 28

SV (mL)

0.26 ± 0.04

0.22 ± 0.05

0.14 ± 0.04*

0.16 ± 0.03*

AoP (mm Hg)

63 ± 5

62 ± 5

67 ± 6

62 ± 5

RVP (mm Hg)

20 ± 1

19 ± 2

30 ± 8*§

28 ± 5*§

TSVR (Wood unit)

0.9 ± 0.14

1.2 ± 0.2

2.1 ± 0.6*

1.7 ± 0.4*

C (mL . mm Hg-1 × 10-3)

9.3 ± 1.6

7.5 ± 1.7

4.5 ± 1.6*§

5.0 ± 0.8*

Eadyn

1.1 (0.7, 1.3)

1.1 (0.8, 1.3)

1.2 (0.9, 1.8)

1.4 (0.9, 2.3)

CVP (mm Hg)

1.8 ± 0.7

0.13 ± 0.7

2.3 ± 0.9§

4.4 ± 1.6*§

  1. Mean ± SD or median (25th, 75th percentiles). *p < 0.05 vs BL; §p < 0.05 vs BW. AoF, AoP aortic flow and pressure, respectively, C arterial capacitance, CVP central venous pressure, Ea dyn dynamic elastance, HR heart rate, RVP right ventricular pressure, SV stroke volume, TSVR total systemic vascular resistance