Clinical application of a novel endoscopic mask: a randomized controlled, multi-center trial in patients undergoing awake fiberoptic bronchoscopic intubation

Abstract

Background

Awake fiberoptic bronchoscopic tracheal intubation is usually regarded as an effective method in the management of predicted difficult airway. Hypoxia during awake nasal fiberoptic bronchoscopic intubation leads to discontinuation of the procedure, prolonged manipulation time and increased risk of severe complications. The main aim of the study was to test whether the novel endoscopic mask is helpful for hypoxia during the intubation.

Methods

This was a randomized, controlled, multi-center study. 55 patients were recruited, but one patient was lost to follow-up. Finally, 54 patients (19 man and 35 women) were analyzed. After entering the operating room, nasal catheter oxygen-providing was given in the control group, and the treatment group received endoscopic mask oxygen-providing, with a flow rate of 3 L/min, lasting into the end of the intubation. Primary outcomes included mean arterial pressure, heart rate, minimum pulse oxygen saturation and incidence of pulse oxygen saturation ≤ 90%. Secondary outcomes included number of intubation attempts and time to intubation. All outcomes were finally measured.

Results

Minimum pulse oxygen saturation during awake nasal fiberoptic bronchoscopic tracheal intubation was significantly higher in the endoscopic mask intubation group (91.7% ± 4.7%) than that the nasal catheter intubation group (87.6% ± 8.2%, P = 0.031. Furthermore, the incidence of pulse oxygen saturation ≤ 90% was significantly lower in the endoscopic mask intubation group (20.0%, 5/25) than that in the nasal catheter intubation group (51.7%, 15/29, P = 0.037). But mean arterial pressure of during intubation was significantly higher in the endoscopic mask group (100.0 ± 13.3 vs 90.3 ± 21.8, P = 0.049). In addition, there were no differences in the number of intubation attempts (P = 0.45) or time to intubation between the two groups (P = 0.38).

Conclusions

The endoscopic mask was safely used in awake fiberoptic bronchoscopic tracheal intubation, with advantages of stable blood pressure and potential prevention of desaturation. Beginners for the intubation procedure and patients at high risk of hypoxia could benefit from the use of the endoscopic mask.

Trial registration

Trial registration: www.chictr.org.cn. Registration No.: ChiCTR-TRC-13004086. Date of Registration: 8th, Sep, 2013.

Peer Review reports

Background

Awake fiberoptic bronchoscopic tracheal intubation is usually regarded as an effective method in the management of predicted difficult airway. However, primary complications during fiberoptic bronchoscopic tracheal intubation, such as epistaxis, laryngeal trauma, laryngospasm, aspiration, respiratory depression, etc., still trouble doctors and patients [1, 2]. Many kinds of agents are used for decreasing discomfort of patients during awake fiberoptic intubation, including propofol, dexmedetomidine, midazolam, diazepam, meperidine, remifentanil, fentanyl [3,4,5]. But fentanyl and propofol can cause respiratory depression [2, 6], which may lead to failure of intubation and additional intubation. Midazolam combined with dexmedetomidine or remifentanil can also result in hypoxemia during fiberoptic intubation [3]. Additional intubation could increase the probability of epistaxis, laryngeal trauma, laryngospasm and aspiration, which may lead to high failure rate and mortality of intubation.

Nasal catheter is the traditional method of oxygen-providing during fiberoptic intubation. We want to develop other methods for sufficient oxygen supply, thus reducing the number of intubation attempts and time-consuming of intubation, and finally improving the success rate and safety during fiberoptic intubation. The purpose of this study was to compare the effectiveness of nasal catheter and novel endoscopic nasal mask (Fig. 1; PRC patent, ZL2012 1 0286504.5) in oxygen-providing during awake nasal fiberoptic bronchoscopic tracheal intubation in patients with difficult airway undergoing surgery.

Fig. 1
figure 1

The endoscopic nasal mask used in this study

Methods

This randomized, controlled, multi-center trial was approved by the ethics committee of Shanghai Tongji Hospital, Shanghai Guanghua Hospital and Shanghai Renji Hospital. The trial was registered in the Chinese Clinical Trial Registry (http://www.chictr.org.cn; registration no.: ChiCTR-TRC-13004086; principal investigator: Bin Yu; date of registration: 8th, Sep, 2013). The subjects were recruited from patients who underwent surgery with predicted difficult airway. Inclusion criteria included patients with mouth disorder, respiratory obstruction, stiff neck, cervical spine fracture dislocation, anterior cervical scar contracture, high laryngeal prominence, short neck and micrognathia. Patients with airway tumor, airway anatomic abnormalities, airway injuries, coagulation abnormalities, taking anticoagulant drugs, skull fracture, giant aneurysm, acute laryngitis, pregnancy and lactation women were excluded.

Before participating in the study, subjects signed written informed consent. Eligible subjects were adult patients with predicted difficult airway. All patients were fasted for 12 h before undergoing awake nasal fiberoptic bronchoscopic tracheal intubation. 0.1 g Phenobarbital and 0.5 mg atropine was given by intramuscular injection before intubation. Electrocardiographic data, heart rate, pulse oxygen saturation, respiration and blood pressure were monitored during the procedures.

Fiberoptic bronchoscope was passed into nose via the nasal opening of the endoscopic nasal mask (Fig. 2). During the procedure, the oxygen-flow rate was set at 3 L/min. The respiratory interface, connected to the oxygen supply equipment, was to be used for first-aid measures if hypoxia occurred.

Fig. 2
figure 2

The endoscopic nasal mask being used during awake nasal fiberoptic bronchoscopic tracheal intubation

The study was a completely-randomized-design study, and subjects were randomly divided into nasal catheter group and endoscopic mask group. The essential information of the subjects who underwent awake nasal intubation was recorded, including sex, age, weight, height, important history and basal pulse oxygen saturation before intubation. Unilateral intravenous access was established via a peripheral vein in the upper limb. Electrocardiographic data, pulse oxygen saturation, respiration, heart rate and blood pressure were monitored. Subjects were randomized to a nasal catheter intubation group and an endoscopic mask intubation group, with both groups receiving oxygen at a flow rate of 3 L/min. In all subjects, intubation was performed after the injection of 2 ml of 2% lidocaine via a thyrocricoid puncture, the bilateral application of ephedrine and furacilin nasal drops, the administration of topical anesthesia in the mouth and throat, and the intravenous injection of 0.05 mg fentanyl and 1.5 mg/kg propofol. Transnasal tracheal intubation was guided by fiberoptic bronchoscope under mild sedation with spontaneous breathing. Anesthesia was induced with propofol and maintained with sevoflurane and propofol. Subjects were sent to the PACU for observation for 1 h after the surgery or to the intensive care unit, and were followed up 24 h later.

Primary outcomes were mean arterial pressure, heart rate, minimum pulse oxygen saturation and incidence of pulse oxygen saturation ≤ 90%. Secondary outcomes included number of intubation attempts and time to intubation.

The incidence rate of respiratory inhibition in patients who underwent awake nasal intubation with endoscopic mask was 0% in the pilot study [7, 8], while the same rate with the use of nasal catheters was 12.5% in a previous study [8]. A minimum of 24 subjects needed to be enrolled in the awake nasal intubation group, with an estimated subject attrition rate of 15%, and so the final requirement was for 28 patients. Continuous variables were compared using the t-test or Mann–Whitney U test, depending on the distribution of the data. Categorical variables were compared using the Pearson chi-square test or Fisher exact test. Statistical significance was assumed at a two-sided P value of <0.05. The results were expressed as mean with standard deviation(SD). Statistical analyses were performed using SPSS version 20.0 (SPSS Inc., Chicago, IL).

Results

A total of 55 patients met the inclusion criteria for awake nasal fiberoptic bronchoscopic tracheal intubation and were randomized (Fig. 3). One patient was lost to follow-up. Thus, finally, the data of 54 patients were analyzed (29 in the nasal catheter intubation group and 25 in the endoscopic mask intubation group), conforming to the minimum sample size required. The baseline characteristics of the patients have been reported in Table 1.

Fig. 3
figure 3

Flow chart of participant selection for awake nasal fiberoptic bronchoscopic tracheal intubation

Table 1 Demographic and clinical characteristics of patients who underwent awake nasal fiberoptic bronchoscopic tracheal intubation group

The trajectories of mean arterial pressure and heart rate in both groups are shown in Fig. 4. The heart rate showed no differences during the entire procedure of intubation, but the mean arterial pressure of during intubation was significantly higher in endoscopic mask group (100.0 ± 13.3 vs 90.3 ± 21.8, P = 0.049). The minimum pulse oxygen saturation during awake nasal fiberoptic bronchoscopic tracheal intubation was significantly higher in the endoscopic mask intubation group (91.7% ± 4.7%) than that in the nasal catheter intubation group (87.6% ± 8.2%, P = 0.031; Table 2). Furthermore, the incidence of pulse oxygen saturation ≤ 90% was significantly lower in the endoscopic mask intubation group (20.0%, 5/25) than that in the nasal catheter intubation group 51.7%, 15/29, P = 0.037). In addition, there were no differences in the number of intubation attempts (P = 0.45) and time to intubation (P = 0.38) between the two groups.

Fig. 4
figure 4

Mean arterial pressure and heart rate for nasal catheter and endoscopic mask intubation groups. BI = Before intubation; DI = During intubation; AI = After intubation

Table 2 Outcomes of awake nasal fiberoptic bronchoscopic tracheal intubation

Discussion

We found the mean arterial pressure in the endoscopic mask group was more stable than in the nasal catheter group during intubation.The endoscopic mask sealed the face and respiratory interface connected to the ventilator allowing oxygen entering the respiratory tract through mouth and nose, thus providing continuous oxygen. The nasal opening allowed simultaneous nasal passage of the bronchofibroscope and endotracheal tube, as well as the oral opening. Once desaturation occurs during the intubation procedure, immediately high oxygen flow or sac pressure oxygen inhalation through the respiratory interface could be used as first-aid measures sequentially without removing the bronchofibroscope or the endotracheal tube. Compared to the common mask, the endoscopic mask was more convenient for tracheal intubation thanks to additional nasal opening and oral opening with continuous oxygen supplement. Moreover, the novel endoscopic mask could be used in other medical procedures, such as gastroscopy, tracheoscopy, choledochoscopy and enteroscopy.

The incidence of desaturations rates <90% in published awake fiberoptic bronchoscopic tracheal intubation studies is between 8 and 14.7% [3, 8,9,10], when oxygen is supplied by standard nasal cannula. Woodall et al. investigated impact of hypoxia on healthy unsedated volunteers undergoing awake fiberoptic bronchoscopic tracheal intubation, and found the incidence of desaturation below 80% was 1.5% when receiving oxygen via standard low-flow nasal cannula [11]. The use of sedatives could increase the incidence of respiratory depression, and the application of lidocaine to the upper airway has been found to reduce dynamic inspiratory airflow during the intubation procedure [12]. The elderly who suffered from cardiorespiratory diseases were more sensitive to hypoxidosis and had a higher risk of rapid oxygen desaturation.

A high-flow humidified transnasal oxygen-delivery system was developed to manage predicted difficult airway during awake fiberoptic bronchoscopic tracheal intubation [13]. The system was observed well tolerated in patients retaining spontaneously breathing undergoing awake fiberoptic bronchoscopic tracheal intubation and augmented oxygenation, thus potentially preventing desaturation arising. Standard nasal cannula can only supply up to 36% fractional inspired oxygen, but the system could provide the patient continuously with 100% fractional inspired oxygen during awake fiberoptic bronchoscopic tracheal intubation.

The Patil mask was designed to overcome the problem of ventilation during fiberoptic intubation [14, 15]. There was only one case of using the Patil mask during gastrointestinal endoscopy. Sundar et al. reported the case of a 36-year-old man with dysphagia in whom upper gastrointestinal endoscopy was performed with the aid of a Patil mask [16]. Unfortunately, this patient suffered from Duchenne muscular dystrophy and could not move any muscle in his body, except to speak. Furthermore, he required continuous positive airway pressure on account of inadequate respiratory power, which could lead to severe hypoxia during upper gastrointestinal endoscopy. Considering the risks of using muscle relaxants in patients with Duchenne muscular dystrophy and the damage that can be caused by the direct insertion of an endotracheal tube through the vocal cords without muscle relaxants, a non-invasive ventilation method was used to facilitate the gastroscopy procedure. With the Patil mask used as an aid for the procedure, the patient’s vital signs remained stable, and he recovered from the anesthesia and left the PACU uneventfully. Actually, our novel endoscopic nasal mask may be another good choice for this special patient and one of objectives of the endoscopic mask was designed to solve the complicated situation like this case. However, we did not design different sizes of mask based on our novel mask fitting for demand of endoscopy in infants and young children, and we will try to improve in this area.

Conclusions

In conclusion, we recommend the endoscopic mask as an oxygen-providing device for patients with predicted difficult airway during awake fiberoptic bronchoscopic tracheal intubation. Stable blood pressure and potential prevention of desaturation could be the advantage of the endoscopic mask, which could provide better teaching and training opportunities for anesthetists especially for beginners of the intubation procedure. We also advocated its use in other medical procedures, such as gastroscopy, tracheoscopy, choledochoscopy and enteroscopy.

References

  1. Collins SR, Blank RS. Fiberoptic intubation: an overview and update. Respir Care. 2014;59:865–78. discussion 78-80

    Article  PubMed  Google Scholar 

  2. Slavkovic Z, Stamenkovic DM, Romic P, Tomic A, Milovic N, Jovanovic M, et al. The present and future of fiberoptic intubation. Vojnosanit Pregl. 2013;70:61–7.

    Article  PubMed  Google Scholar 

  3. Li CW, Li YD, Tian HT, Kong XG, Chen K. Dexmedetomidine-midazolam versus Sufentanil-midazolam for awake fiberoptic nasotracheal intubation: a randomized double-blind study. Chin Med J. 2015;128:3143–8.

    Article  PubMed  PubMed Central  Google Scholar 

  4. Hu R, Liu JX, Jiang H. Dexmedetomidine versus remifentanil sedation during awake fiberoptic nasotracheal intubation: a double-blinded randomized controlled trial. J Anesth. 2013;27:211–7.

    Article  PubMed  Google Scholar 

  5. Bergese SD, Patrick Bender S, McSweeney TD, Fernandez S, Dzwonczyk R, Sage K. A comparative study of dexmedetomidine with midazolam and midazolam alone for sedation during elective awake fiberoptic intubation. J Clin Anesth. 2010;22:35–40.

    Article  CAS  PubMed  Google Scholar 

  6. Hillman DR, Walsh JH, Maddison KJ, Platt PR, Kirkness JP, Noffsinger WJ, et al. Evolution of changes in upper airway collapsibility during slow induction of anesthesia with propofol. Anesthesiology. 2009;111:63–71.

    Article  CAS  PubMed  Google Scholar 

  7. Da Conceicao M, Favier JC, Bidallier I, Armanet L, Steiner T, Genco G, et al. Fiber-optic intubation with non-invasive ventilation with an endoscopic facial mask. Ann Fr Anesth Reanim. 2002;21:256–62.

    Article  PubMed  Google Scholar 

  8. Bourgain JL, Billard V, Cros AM. Pressure support ventilation during fibreoptic intubation under propofol anaesthesia. Br J Anaesth. 2007;98:136–40.

    Article  CAS  PubMed  Google Scholar 

  9. Fuchs G, Schwarz G, Baumgartner A, Kaltenbock F, Voit-Augustin H, Planinz W. Fiberoptic intubation in 327 neurosurgical patients with lesions of the cervical spine. J Neurosurg Anesthesiol. 1999;11:11–6.

    Article  CAS  PubMed  Google Scholar 

  10. Rodrigues AJ, Scordamaglio PR, Palomino AM, Oliveira EQ, Jacomelli M, Figueiredo VR. Difficult airway intubation with flexible bronchoscope. Braz J Anesthesiol. 2013;63:358–61.

    Article  Google Scholar 

  11. Woodall NM, Harwood RJ, Barker GL. Complications of awake fibreoptic intubation without sedation in 200 healthy anaesthetists attending a training course. Br J Anaesth. 2008;100:850–5.

    Article  CAS  PubMed  Google Scholar 

  12. Ho AM, Chung DC, Karmakar MK, Gomersall CD, Peng Z, Tay BA. Dynamic airflow limitation after topical anaesthesia of the upper airway. Anaesth Intensive Care. 2006;34:211–5.

    CAS  PubMed  Google Scholar 

  13. Badiger S, John M, Fearnley RA, Ahmad I. Optimizing oxygenation and intubation conditions during awake fibre-optic intubation using a high-flow nasal oxygen-delivery system. Br J Anaesth. 2015;115:629–32.

    Article  CAS  PubMed  Google Scholar 

  14. Aoyama K, Takenaka I. Patil-Syracuse mask for fiberoptic intubation. Masui. 1999;48:1262–6.

    CAS  PubMed  Google Scholar 

  15. Komatsu K, Bamba N, Komota S, Sato H, Fuse M, Nakamura N, et al. Fiberoptic bronchoscopy-aided tracheal intubation using a patil-syracuse mask in a "can ventilate/cannot intubate" situation. Masui. 1999;48:301–3.

    CAS  PubMed  Google Scholar 

  16. Sundar E, Zimmer S, Brown A. The Patil mask as an aid for gastrointestinal endoscopy. Anesth Analg. 2013;116:1186–7.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

We would like to thank Prof. Zisheng Ai (Tongji University School of Medicine, Shanghai, China) for his assistance with the study.

Funding

Supported by Shanghai Science and Technology Commissim (1411965600).

Availability of data and materials

The datasets used and analyzed during the current study were available from the corresponding author on reasonable request.

Authors’ contributions

TXZ, ZLH and XXH analyzed and interpreted the patient data. TXZ, ZLH, XXH, GYC, MH, SJW, PH and BY performed the experiment. TXZ, ZLH and XXH were major contributors in writing the manuscript. All authors read and approved the final manuscript.

Competing interests

The authors declare that they have no competing interests.

Consent for publication

Not applicable.

Ethics approval and consent to participate

This randomized, controlled, multi-center trial was approved by the ethics committee of Shanghai Tongji Hospital, Shanghai Guanghua Hospital and Shanghai Renji Hospital. The trial was registered in the Chinese Clinical Trial Registry (http://www.chictr.org.cn; registration no.: ChiCTR-TRC-13004086; principal investigator: Bin Yu; date of registration: 8th, Sep, 2013). Written consent has been obtained from each patient to participate this study.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Bin Yu.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zou, T., Huang, Z., Hu, X. et al. Clinical application of a novel endoscopic mask: a randomized controlled, multi-center trial in patients undergoing awake fiberoptic bronchoscopic intubation. BMC Anesthesiol 17, 79 (2017). https://doi.org/10.1186/s12871-017-0370-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12871-017-0370-y

Keywords