Skip to main content
  • Research article
  • Open access
  • Published:

Hemoglobin Vesicles prolong the time to circulatory collapse in rats during apnea

Abstract

Background

Hemoglobin vesicles (HbV) are hemoglobin-based oxygen carriers manufactured by liposome encapsulation of hemoglobin molecules. We hypothesised that the infusion of oxygenated HbV could prolong the time to circulatory collapse during apnea in rats.

Methods

Twenty-four Sprague-Dawley rats were randomly divided into four groups (Air, Oxy, NS and HbV). The rats were anaesthetized with isoflurane and the trachea was intubated using 14-gauge intravenous catheters. Rats in the Air group were mechanically ventilated with 1.5% isoflurane in room air, and those in other groups received 1.5% isoflurane in 100% oxygen. Mechanical ventilation was withdrawn 1 min after the administration of rocuronium bromide to induce apnea. After 30 s, 6 mL saline and HbV boluses were infused at a rate of 0.1 mL/s in the NS and HbV groups, respectively. Circulatory collapse was defined as a pulse pressure < 20 mmHg and the time to reach this point (PP20) was compared between the groups. The results were analysed via a one-way analysis of variance and post-hoc Holm–Sidak test.

Results

PP20 times were 30.4 ± 4.2 s, 67.5 ± 9.7 s, 95 ± 17.3 s and 135 ± 38.2 s for the Air (ventilated in room air with no fluid bolus), Oxy (ventilated with 100% oxygen with no fluid bolus), NS (ventilated with 100% oxygen with a normal saline bolus), and HbV (ventilated in 100% oxygen with an HbV bolus) groups, respectively, and differed significantly between the four groups (P = 0.0001). The PP20 times in the HbV group were significantly greater than in the Air (P = 0.0001), Oxy (P = 0.007) and NS (P = 0.04) groups.

Conclusion

Infusion of oxygenated HbV prolongs the time to circulatory collapse during apnea in rats.

Peer Review reports

Background

The situation ‘cannot ventilate, cannot intubate (CVCI)’ during the induction of anaesthesia is one of the most serious complications anaesthesiologists can encounter. In some cases, supraglottic airway devices may help to maintain oxygenation, but otherwise, the reinitiation of spontaneous ventilation by waking the patient, or the initiation of emergency intubation pathways, should be considered [1]. Even after the introduction of fast-acting drugs and Sugammadex, the time required for the reestablishment of spontaneous breathing is often longer than expected [2]. Emergency intubation pathways commonly involve invasive airway access that require at least a few minutes of preparation. These techniques are also highly invasive, and each carries a substantial risk of technical complications [3].

Hemoglobin vesicles (HbV) are a type of cellular Hb-based oxygen carrier (HBOC) manufactured by the encapsulation of a purified, concentrated Hb solution using liposomes [4]. Moreover, HbV was developed as an alternative to red blood cell (RBC) transfusion and has exhibited efficacy as components of the resuscitative fluid used to treat haemorrhagic shock in emergency situations using animal models [5, 6]. The absence of a blood type antigen and infectious viruses, the small particle size required for penetration via constricted vessels through which red blood cells cannot penetrate, and the stability for long-term storage at room temperature are also important advantages of HbV [7]. In practice, HbV is stored in a deoxygenated state, but is rapidly oxygenated and administered within extremely short time periods. Therefore, we hypothesised that the infusion of oxygenated HbV could maintain oxygenation in critical situations (e.g. CVCI) after the induction of anaesthesia. Accordingly, we tested whether the administration of HbV could prolong the time to circulatory collapse during apnea in a rat model.

Methods

All experiments were conducted using 24 male Sprague-Dawley rats (300–330 g, 10 weeks old). All animals were purchased from SLC Inc., Shizuoka, Japan. The animals were housed on a bed of cellulose paper in a ventilated, temperature controlled, specific-pathogen-free environment with a 12-h light-dark cycle. The animals were provided with access to food and water ad libitum. All experimental protocols were reviewed by the Committee on the Ethics of Animal Experiments at our University and were conducted in accordance with the Guidelines for Animal Experiments issued by the Nara Medical University and with law no. 105 (Act on Welfare and Management of Animals) issued by the Japanese government. The ethical guidelines conformed to the guiding principles issued by the National Academy of Science.

Pilot study to define circulatory collapse

To perform a thorough investigation, we first sought to define the criteria for circulatory collapse. There are previous reports of apnea in rat models; however, there is no consensus on the definition of circulatory collapse in these reports [8, 9]. Moreover, a number of previous studies have used the mean arterial pressure or systolic blood pressure to define circulatory collapse [10, 11]; however, these criteria were not used in the present study as volume infusions lead to a 30% increase in the total blood volume of the rats, likely resulting in an increased mean arterial and systolic blood pressure. Instead, we used the pulse pressure to define circulatory collapse in our study. We assessed a range of pulse pressures (5, 10, 15, 20 and 25 mmHg) as surrogates of circulatory collapse. The same equipment and drugs described in the experimental methodology were used in this pilot study. In brief, five rats were orally intubated after the induction of anaesthesia via the inhalation of 5% isoflurane in 100% oxygen. The trachea of the rats was then intubated using 14-gauge intravenous catheters. Mechanical ventilation was initiated with 1.5% isoflurane in room air at 1 L/min and oxygen at 1 L/min to maintain an FIO2 of 0.6. Adequate anaesthesia was confirmed by the absence of the pedal withdrawal reflex in response to tail pinching. Polyethylene catheters were introduced into the tail arteries to monitor the arterial blood pressure. Polyethylene catheters were also introduced into the external right jugular vein for the purpose of drug administration. Apnea was induced by the administration of 1 mg of rocuronium bromide to inhibit spontaneous breathing followed by extubation. The apnea times for the pulse pressures of 5, 10, 15, 20 and 25 mmHg were recorded. The mean arterial and systolic blood pressures were also recorded for a comparison with the pulse pressure. Coefficients of variation (CV, standard deviation divided by the mean value) were calculated. The pulse pressure with the lowest CV was defined as a circulatory collapse.

Preparation of HbV

HbV was prepared under sterile conditions, according to previously reported methods with only slight modifications [12]. Hemogloin (Hb) was purified from outdated donated human blood provided by the Japanese Red Cross Society (Tokyo, Japan). First, Hb was stabilised using carbonylation (HbCO) and pasteurized (60 °C for 12 h) to inactivate any viruses. All unstable enzymes are also eliminated by this procedure. The obtained Hb solution was concentrated by ultrafiltration to 42 g/dL. Subsequently, pyridoxal 5’-phosphate (PLP; Sigma Chemical Co., St. Louis, MO) was added to the HbCO solution as an allosteric effector at a molar ratio of PLP/Hb tetramer = 1. The Hb solution with PLP was then mixed with lipids and encapsulated in vesicles. The lipid bilayer comprised 1,2-dipalmitoyl-sn-glycero-3-phosphatidylcholine, cholesterol, 1,5-O-dihexadecyl-N-succinyl-L-glutamate (Nippon Fine Chemical Co. Ltd., Osaka, Japan) and 1,2-distearoyl-sn-glycerol-3-phosphatidylethanolamine-N-PEG5000 (NOF Corp., Tokyo, Japan) at a molar ratio of 5:4:0.9:0.03, respectively. The encapsulated HbCO was converted to HbO2 by exposing the liquid membranes of HbV to visible light under an O2 atmosphere. HbV was dialysed in normal saline to adjust the Hb concentration to 10 g/dL. Finally, the preparation was completely deoxygenated for long-term storage. The physiochemical parameters of HbV are as follows; P50, 17 - 23 mmHg; 251 ± 81 nm particle diameter; and less than 10% metHb content. Immediately before administration, deoxygenated HbV was drawn into a 10-mL syringe (Terumo Co., Tokyo, Japan) and rapidly oxygenated by mixing with air.

Main experimental design

A schematic of the experimental design is shown in Fig. 1. Before the experiment, the rats were randomised into four groups (Air, Oxy, NS and HbV groups) and anaesthetised via the inhalation of 5% isoflurane (Mylan Inc. PA, USA) in 100% oxygen inside a plastic chamber. Once unconscious, tracheal intubation was performed using a 14-gauge intravenous catheter via direct laryngoscopy. The rats in the Air group were mechanically ventilated with 1.5% isoflurane in room air, while the rats in the other groups were ventilated with 1.5% isoflurane in 100% oxygen. All mechanical ventilation was performed using a small animal ventilator (Harvard Model 683, HARVARD APPARATUS, MA, USA). The respiratory rate was set to maintain pCO2 at 35–45 mmHg. The typical ventilator rates ranged between 55 and 65 breaths/min with a tidal volume of 8 mL/kg. The adequate anaesthesia depth was confirmed as described in the pilot study. Polyethylene catheters (SP45) filled with heparinised normal saline were inserted into the tail arteries to measure the arterial pressure. Polyethylene catheters filled with heparinised normal saline (SP55) were introduced via the right jugular vein into the right atrium for the purpose of drug infusion. Both types of polyethylene catheters were purchased from Natsume Seisakusho Co. Ltd. Tokyo, Japan. The blood pressure and pulse rate were monitored using a continuous monitoring system (PROPAQ 204 EL; Welch Allyn. NY, USA). The rectal temperature was maintained between 36.0 °C and 37.5 °C with the aid of thermal lighting during experiments. The baseline (3 min before insult) arterial blood analysis was performed (GEM Premiere 3000; Instrumental Laboratory, MA, USA) following the administration of 300 units of heparin to ensure that all values were within the normal range.

Fig. 1
figure 1

Outline of the experiment protocol. After the administration of rocuronium bromide, the mechanical ventilation was withdrawn to establish apnea. The apnea time to a pulse pressure less than 20 mmHg was compared between the groups

Induction of apnea

A total dose of 1 mg rocuronium bromide (MSD. Inc., Tokyo, Japan) was administered while the animals were still under anaesthesia. The tracheal tubes were then removed and mechanical ventilation was withdrawn to establish apnea. The animals were visually observed to ensure that spontaneous breathing did not recover during the experiments. In addition, the rats in the Air and Oxy groups did not receive a fluid infusion during apnea. After a 30-s interval following ventilation withdrawal, the rats in NS and HbV groups received infusions of 6 mL normal saline or HbV, respectively, at a rate of 0.1 mL/s. The blood pressure and pulse rate were continuously recorded following the withdrawal of mechanical ventilation using a monitor display and video camera (iPad mini; Apple Inc., CA, USA). We defined a circulatory collapse as a pulse pressure less than 20 mmHg according to our preliminary study. The time to a pulse pressure less than 20 mmHg (PP20) was compared between the groups as the primary study outcome. Video recording was continued until the pulse pressure fell below 10 mmHg or until 180 s had expired. After the experiment, all rats were euthanised by an intravenous administration of 4 mEq potassium chloride.

Randomisation and blinding of the experiment

The animals were randomly assigned to four groups before the induction of apnea. Randomisation was performed using a computer-generated randomisation table. The investigators who performed the experiments were not blinded since it was easy to distinguish which fluid was administered. The video recordings were investigated by a researcher who was blinded to the animal groups.

Statistical analyses

Fully saturated Hemoglobin vesicles contain approximately 0.8 mL oxygen in a 6-mL solution according to the formula: Oxygen Content = 1.34 * [Hb] * [SaO2] = 1.34 * 10* 1.00. The oxygen consumption of adult rats is reported to be 0.68 mL/g/h (0.056 mL/s) [13]. We considered half of the time derived from the calculation (8 s) to be clinically significant (between group variance = 64). The within group variance calculated from the pilot study was 55.

A power analysis demonstrated that a group size of n = 5 was necessary to detect a difference in the mean PP20 values between the groups assuming a statistical power of 0.8 at a significance level of 0.05. We included six rats in each group to mitigate any loss due to accidental death or circulatory collapse during the study.

Means ± standard deviation are reported for all measurements unless otherwise specified. All of the data sets were analysed using Statflex software (Artech Inc., Tokyo, Japan). To reduce multiple comparisons, differences in the haemodynamic changes during apnea were compared at three time points (30, 90 and 150 s) by a repeated measure ANOVA followed by the Holm–Sidak test. Thirty seconds following the establishment of apnea was selected as the first time point as the fluid infusions were initiated at this time. As the fluids were infused for a duration of 60 s, the next time point used was 90 s, and a further time point at 150 s was chosen to maintain consistent intervals. Differences in the PP20 between each of the groups were analysed by a one-way ANOVA followed by the Holm–Sidak test. Since PP20 is a time-to-event variable, we also plotted it as a Kaplan-Meier curve with a log-rank analysis. The P values correspond to two-tailed tests with statistical significance set at P < 0.05.

Results

Pilot study to define circulatory collapse

The results of the ‘Pilot study to define circulatory collapse’ are presented in Table 1. We found that the apnoea time to a pulse pressure lower than 20 mmHg had the lowest CV value of 0.18. Therefore, we defined a pulse pressure lower than 20 mmHg as a surrogate outcome for the circulatory collapse in our main study.

Table 1 Study results of the apnea times to haemodynamic values

Baseline measurements

The initial body weight, preparation time and blood loss until apnea demonstrated small standard deviations within each group and did not differ significantly between groups. One rat in the Air group was excluded from the study due to a technical error. Therefore, all the results shown below are derived from 23 rats (n = 5 for the Air group; n = 6 for all the other groups).

The systolic blood pressure, mean arterial pressure, pulse pressure and pulse rate measurements at baseline for each group are shown in Table 2. The rats in the Air group exhibited a lower systolic blood pressure, mean arterial pressure and pulse pressure at baseline compared to the other groups. No significant difference in the systolic blood pressure, mean arterial pressure, or pulse pressure was observed between the NS, Oxy and HbV groups. The pulse rate at baseline was similar between all groups.

Table 2 Haemodynamic variables at baseline

The baseline blood analysis was performed prior to the induction of apnea. Table 3 summarises the baseline blood analyses. Rats in the Air group had significantly lower pO2 as they were ventilated with room air while the other groups were ventilated with 100% oxygen. All of the other variables were within the normal range with no differences were observed between groups.

Table 3 Baseline arterial blood analysis

Haemodynamic changes during apnea

The systolic blood pressure, mean arterial pressure and pulse pressure measurements at 60 s intervals for each group are shown in Fig. 2. The systolic blood pressure, mean arterial pressure and pulse pressure was significantly lower in the Air group at 30 s compared to the other groups, while no differences were observed between the Oxy, NS and HbV groups. At 90 s, the systolic blood pressure, mean arterial pressure and pulse pressure were significantly higher in the HbV group compared to all other groups. At 150 s, the pulse pressure in the HbV group was higher compared to the Air group, while there were no significant differences between the Oxy and NS groups. However, the systolic blood pressure and mean arterial pressure in the HbV group were consistently significantly higher than the Oxy and NS groups.

Fig. 2
figure 2

Haemodynamic changes after the withdrawal of mechanical ventilation. Systolic blood pressure (a), mean arterial pressure (b) and pulse pressure (c) for each group are shown. The rats in the Air group were ventilated with room air while the other groups were ventilated with 100% oxygen. The NS group were infused with 6 mL normal saline and the HbV group was infused with 6 mL HbV. The arrows indicate periods of fluid infusion. The differences between the groups were analysed by a one-way repeated measure ANOVA followed by a Holm-Sidak test. SBP, systolic blood pressure; MAP, mean arterial pressure; PP, pulse pressure. Symbols represent significant differences. *: P < 0.05; ** P < 0.01; *** P < 0.001

Apnea time to a pulse pressure less than 20 mmHg (PP20)

The apnea time to a pulse pressure less than 20 mmHg (PP20) was compared between the four groups as the primary outcome of this study. The mean PP20 values ± standard deviation were 30.4 ± 4.2 s, 67.5 ± 9.7 s, 95 ± 17.3 s and 135 ± 38.2 s for the Air, Oxy, NS and HbV groups, respectively. The mean PP20 values for all groups significantly differed from every other group by a one-way ANOVA followed by Holm-Sidak test (Air vs. Oxy P = 0.0001; Air vs. NS P = 0.0001, Air vs. HbV P = 0.002, Oxy vs. NS P = 0.002, Oxy vs. HbV P = 0.007 and NS vs. HbV P = 0.04). The Kaplan-Meier curves for the apnea time to a pulse pressure less than 20 mmHg are plotted in Fig. 3. A long rank analysis revealed statistical differences between the four groups. (Air vs. HbV P = 0.004; Oxy vs. HbV, P = 0.003; NS vs. HbV, P = 0.045). There were also similar trends regarding the time to reach pulse pressures below 15 [see Additional file 1] and 10 mmHg [see Additional file 2] between the groups.

Fig. 3
figure 3

A Kaplan-Meier curve for the apnea time to a pulse pressure less than 20 mmHg for each group. There was a statistically significant difference between the groups assessed by a log-rank test (Air vs. HbV P = 0.004; Oxy vs. HbV, P = 0.003; NS vs. HbV, P = 0.045)

Discussion

To the best of our knowledge, this is the first report to demonstrate the effect of hemoglobin based oxygen carrier (HBOC) therapy during apnea. We found that the administration of oxygenated HbV more than doubled the apnea time to circulatory collapse when compared to the Oxy group.

In 1949, Amberson reported the first case series of clinical experiences using an Hb-saline solution [14]. Although it was effective for the delivery of oxygen, the Hb-saline solution was found to be associated with high renal toxicity and vasopressive reactions; therefore, its use was discontinued. Subsequently, a large variety of modified HBOCs have been developed in an attempt to overcome these complications. These include cross-linked polyHb, conjugated Hb, cross-linked tetrameric Hb, recombinant human Hb, and HbV [10, 11, 1517]. A number of these modified HBOCs have also been used to treat anaemic patients for whom a blood transfusion is not readily available [18]. However, other reports have indicated that these products are still associated with significant toxic properties that have been attributed to myocardial infarction, acute renal failure, a deleterious increase in arterial blood pressure, and death [19, 20]. Such complications resulting from the use of HBOCs are thought to be mediated by the direct interaction between molecular Hb and the blood or endothelial cells; thus, preventing this direct contact via the encapsulation of Hb may lessen these complications. Previous studies have demonstrated that HbV does not exhibit renal toxicity or cause vasoconstriction [21]. Therefore, we can safely affirm that the haemodynamic difference observed in our study were not attributed to vasoconstriction.

Theoretically, an infusion of 6 mL HbV will prolong the apnea time to circulatory collapse by 15 s. To our surprise, the mean difference between the Oxy and the HbV groups was found to be 67.5 s. This discrepancy may be explained by the results from the NS group. The NS group was included to assess the effect of the infusion volume since HbV does not have collioid osmotic pressure. We predicted that an infusion greater than 30% of the total circulating volume would lead to acute heart failure, shortening the PP20 in the NS group. However, the PP20 in the NS group was higher than that of the Oxy group. One reason for this might be the blood viscosity. Infusing normal saline causes haemodilution, resulting in a better cardiac contraction in the NS and HbV groups. Recently, it has been demonstrated that a saline infusion, while increasing the left ventricular end diastolic volume, also decreases the left ventricular end systolic volume resulting in increased cardiac contraction [22]. Although the administration of normal saline may have an impact on the time to circulatory collapse, any negative effects (e.g. high chloride acidosis or hypernatremia) should be noted. Another possible explanation involves a higher level of effective oxygen transport by HbV than RBCs to the myocardium, as it has a high oxygen consumption and steep oxygen tension gradient. Since HbV is smaller than RBCs, it is distributed closer to the endothelial cell layer during arteriolar blood flow, whereas RBCs flow closer to the axial line [23]. Biochemical data (e.g. base excess or lactate levels) may have been informative and supported our analyses; however, blood samples from the tail artery during circulatory collapse were not obtained.

We used the pulse pressure to define circulatory collapse in our study. The apnea time to reach a pulse pressure less than 20 mmHg had the lowest coefficient of variation (CV); a low CV value indicates high reproducibility. Although the pulse pressure at baseline in our results was close to 20 mmHg, all of the animals exhibited an increased pulse pressure and systolic blood pressure, reflecting a hyper haemodyanamic state following apnoea. Moreover, this phenomenon is consistantly observed in this model [9], indicating that the actual pulse pressure decreased from a higher value (i.e. 40 mmHg). Finally, we chose a pulse pressure less than 20 mmHg as an outcome of this study based on our predefined protocol; however, there were also similar trends regarding the time to reach pulse pressures below 15 and 10 mmHg between the groups.

Finally, the infusion of oxygenated hemoglobin (artificial or not) will increase the total amount of oxygen in the body. Therefore, our experimental results are natural in most part. However, HbV is an artificial RBC, which can be stored at room temperature for more than 2 years. Moreover, the time required for the oxygenation of HbV in our experiment was within 5 s. During critical hypoxic situations (e.g. CVCI), the time required for the preparation of the drug would be essential.

Limitations

Although all experiments were performed as thoroughly as possible, there are some limitations to this study. Firstly, we used the tail arteries to monitor any haemodynamic changes. As the tail artery is a small peripheral artery, the pulse pressure may be affected more by factors, such as blood pressure, blood volume and cardiac contractility. Thus, it may not be entirely reflective of the central haemodynamics, especially when the rats were in a state of near circulatory collapse. We have added one additional experiment to overcome this limitation, in which we monitored the pulse pressure in the tail artery and left common carotid artery consecutively. We found a strong relationship between the pulse pressures; however, they deviated greatly after the pulse pressure in the tail artery dropped lower than 25 mmHg. This may account for the finding that the CV was the lowest for 20 mmHg but increased for the lower pulse pressures. In addition, the femoral artery or descending aorta may have more accurately assessed the central circulation in this study.

Secondly, our results may have been confounded by the significantly lower haemodynamic variables in the Air group compared to other groups at baseline. However, we do not believe this to be a serious limitation of our study as we successfully achieved the main endpoint by demonstrating that the HbV group exhibited a prolonged time to collapse compared to the Oxy and NS groups.

Conclusion

The infusion of HbV during apnoea in rats prolonged the time to circulatory collapse. The demonstration of HbV utility in a state of apnoea suggests that HbV may be efficacious as a bridging therapy in CVCI situations encountered clinically.

Abbreviations

ANOVA:

Analysis of variance

CV:

Coefficients of variation

CVCI:

Cannot ventilate, cannot intubate

Hb:

Hemogloin

HBOC:

Hb-based oxygen carrier

HbV:

Hemoglobin vesicles

PLP:

Pyridoxal 5’-phosphate

RBC:

Red blood cell

References

  1. Apfelbaum JL, Hagberg CA, Caplan RA, Blitt CD, Connis RT, Nickinovich DG, et al. Practice guidelines for management of the difficult airway: an updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Anesthesiology. 2013;118:251–70.

    Article  PubMed  Google Scholar 

  2. Curtis R, Lomax S, Patel B. Use of sugammadex in a ‘can’t intubate, can’t ventilate’ situation. Br J Anaesth. 2012;108:612–4.

    Article  CAS  PubMed  Google Scholar 

  3. Murphy C, Rooney SJ, Maharaj CH, Laffey JG, Harte BH. Comparison of three cuffed emergency percutaneous cricothyroidotomy devices to conventional surgical cricothyroidotomy in a porcine model. Br J Anaesth. 2011;106:57–64.

    Article  CAS  PubMed  Google Scholar 

  4. Sou K, Naito Y, Endo T, Takeoka S, Tsuchida E. Effective encapsulation of proteins into size-controlled phospholipid vesicles using freeze-thawing and extrusion. Biotechnol Prog. 2003;19:1547–52.

    Article  CAS  PubMed  Google Scholar 

  5. Sakai H, Horinouchi H, Yamamoto M, Ikeda E, Takeoka S, Takaori M, et al. Acute 40 percent exchange-transfusion with hemoglobin-vesicles (HbV) suspended in recombinant human serum albumin solution: degradation of HbV and erythropoiesis in a rat spleen for 2 weeks. Transfusion. 2006;46:339–47.

    Article  CAS  PubMed  Google Scholar 

  6. Seishi Y, Horinouchi H, Sakai H, Kobayashi K. Effect of the cellular-type artificial oxygen carrier hemoglobin vesicle as a resuscitative fluid for prehospital treatment: experiments in a rat uncontrolled hemorrhagic shock model. Shock. 2012;38:153–8.

    Article  CAS  PubMed  Google Scholar 

  7. Sakai H, Tomiyama KI, Sou K, Takeoka S, Tsuchida E. Poly (ethylene glycol)-conjugation and deoxygenation enable long-term preservation of hemoglobin-vesicles as oxygen carriers in a liquid state. Bioconjug Chem. 2000;11:425–32.

    Article  CAS  PubMed  Google Scholar 

  8. Fink EL, Alexander H, Marco CD, Dixon CE, Kochanek PM, Jenkins LW, et al. Experimental model of pediatric asphyxial cardiopulmonary arrest in rats. Pediatr Crit Care Med. 2004;5:139–44.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Katz L, Ebmeyer U, Safar P, Radovsky A, Neumar R. Outcome model of asphyxial cardiac arrest in rats. J Cereb Blood Flow Metab. 1995;15:1032–9.

    Article  CAS  PubMed  Google Scholar 

  10. Chang TM. Semipermeable microcapsules. Science. 1964;146:524–5.

    Article  CAS  PubMed  Google Scholar 

  11. Wong JT. Rightshifted dextran-hemoglobin as blood substitute. Biomater Artif Cells Artif Organs. 1988;16:237–45.

    Article  CAS  PubMed  Google Scholar 

  12. Sakai H, Hara H, Yuasa M, Tsai AG, Takeoka S, Tsuchida E, et al. Molecular dimensions of Hb-based O2 carriers determine constriction of resistance arteries and hypertension. Am J Physiol Heart Circ Physiol. 2000;279:908–15.

    Google Scholar 

  13. Tajima Y. Jikken Doubutsugaku. Tokyo: Asakura Publishing; 1972.

  14. Amberson WR, Jennings JJ, Rhode CM. Clinical experience with hemoglobin-saline solutions. J Appl Physiol. 1949;1:469–89.

    CAS  PubMed  Google Scholar 

  15. Iwashita Y, Yabuki A, Yamaji K, Iwasaki K, Okami T, Hirata C, et al. A new resuscitation fluid “stabilized hemoglobin” preparation and characteristics. Biomater Artif Cells Artif Organs. 1988;16:271–80.

    Article  CAS  PubMed  Google Scholar 

  16. Bunn HF, Jandl JH. The renal handling of hemoglobin. Trans Assoc Am Physicians. 1968;81:147–52.

    CAS  PubMed  Google Scholar 

  17. Doherty DH, Doyle MP, Curry SR, Vali RJ, Fattor TJ, Olson JS, et al. Rate of reaction with nitric oxide determines the hypertensive effect of cell-free hemoglobin. Nat Biotechnol. 1998;16:672–6.

    Article  CAS  PubMed  Google Scholar 

  18. Mackenzie CF, Moon-Massat PF, Shander A, Javidroozi M, Greenburg AG. When blood is not an option: factors affecting survival after the use of a hemoglobin-based oxygen carrier in 54 patients with life-threatening anemia. Anesth Analg. 2010;110:685–93.

    Article  CAS  PubMed  Google Scholar 

  19. Lamy ML, Daily EK, Brichant JF, Larbuisson RP, Demeyere RH, Vandermeersch EA, et al. Randomized trial of diaspirin cross-linked hemoglobin solution as an alternative to blood transfusion after cardiac surgery. The DCLHb Cardiac Surgery Trial Collaborative Group. Anesthesiology. 2000;92:646–56.

    Article  CAS  PubMed  Google Scholar 

  20. Natanson C, Kern SJ, Lurie P, Banks SM, Wolfe SM. Cell-free hemoglobin-based blood substitutes and risk of myocardial infarction and death: a meta-analysis. JAMA. 2008;299:2304–12.

    Article  CAS  PubMed  Google Scholar 

  21. Sakai H, Hara H, Yuasa M, Tsai AG, Takeoka S, Tsuchida E, et al. Molecular dimensions of Hb-based O2 carriers determine constriction of resistance arteries and hypertension. Am J Physiol Heart Circ Physiol. 2000;279:H908–15.

    CAS  PubMed  Google Scholar 

  22. Robotham JL. Saline volume expansion and cardiovascular physiology: novel observations, old explanations, and new questions. Crit Care. 2004;8:315–8.

    Article  PubMed  PubMed Central  Google Scholar 

  23. Sakai H, Tsai AG, Rohlfs RJ, Hara H, Takeoka S, Tsuchida E, et al. Microvascular responses to hemodilution with Hb vesicles as red blood cell substitutes: influence of O2 affinity. Am J Physiol Heart Circ Physiol. 1999;276:H553–62.

    CAS  Google Scholar 

Download references

Acknowledgements

The authors would like to thank Enago (www.enago.jp) for English language review.

Funding

This work was supported in part by Japanese Society for the promotion of Science grant. No funding was involved in in the design of the study and collection, analysis, and interpretation of data and in writing the manuscript.

Availability of data and materials

The datasets generated during the current study are available from the corresponding author on reasonable request.

Authors’ contributions

YN: Study design, conducting experiment, data collection, data analysis and writing the first draft of the paper; SI: Data collection, data analysis and making advice for writing the first draft of the paper; HS: Preparation of Hemoglobin Vesicles, and making advice for writing the first draft of the paper; MK: Reviewing the first draft of the paper and rewriting. All authors read and approved the final manuscript.

Competing interests

The authors declare that they have no competing interests.

Consent for publication

Not applicable.

Ethics approval

The experiments were performed in 24 male rats (Sprague-Dawley, 300–330 g, 10 weeks old).

All experimental protocols were reviewed by the Committee on the Ethics of Animal Experiments at our University and were conducted in accordance with the Guidelines for Animal Experiments issued by the Nara Medical University and with law no. 105 (Act on Welfare and Management of Animals) issued by the Japanese government. The ethical guidelines conformed to the guiding principles issued by National Academy of Science.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yusuke Naito.

Additional files

Additional file 1: Figure S1.

A Kaplan-Meier curve for the apena time to a pulse pressure less than 15 mmHg for each group is shown. The PP15 times were 31.2 ± 5.1 s, 78.8 ± 21.0 s, 121 ± 53.8 s and 155 ± 44.4 s for the Air, Oxy, NS and HbV groups, respectively. Log-rank test revealed statistical difference between HbV and Air (P = 0.006), HbV and Oxy (P = 0.003) but did not differ between HbV and NS (P = 0.04). (PNG 133 kb)

Additional file 2: Figure S2.

A Kaplan-Meier curve for the apena time to a pulse pressure less than 10 mmHg for each group is shown. The PP10 times were 58.8 ± 35.8 s, 136 ± 52.6 s, 155 ± 68.8 s and 190 ± 32.9 s for the Air, Oxy, NS and HbV groups, respectively. Log-rank test revealed statistical difference between HbV and Air (P = 0.006), HbV and Oxy (P = 0.04) but did not differ between HbV and NS (P = 0.82). (PNG 116 kb)

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Naito, Y., Sakai, H., Inoue, S. et al. Hemoglobin Vesicles prolong the time to circulatory collapse in rats during apnea. BMC Anesthesiol 17, 44 (2017). https://doi.org/10.1186/s12871-017-0338-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12871-017-0338-y

Keywords